Gonzalo Gutiérrez-Tobal

Dr. Gonzalo Gutiérrez-Tobal

Biomedical Engineering Group, Universidad de Valladolid, Paseo Belén 15, 47011, Valladolid, Spain
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2018 in Entropy
Verified
Journal Article
Open access
PDF file
SRSaúl J. Ruiz-Gómez
Saúl J. Ruiz-Gómez
Carlos GómezCarlos Gómez
Carlos Gómez
JPJesus Poza
Jesus Poza
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
MTMiguel A. Tola-Arribas
Miguel A. Tola-Arribas
Roberto HorneroRoberto Hornero
Roberto Hornero
The discrimination of early Alzheimer’s disease (AD) and its prodromal form (i.e., mild cognitive impairment, MCI) from cognitively healthy control (HC) subjects is crucial since the treatment is more effective in the first stages of the dementia. The aim of our study is to evaluate the usefulness of a methodology based on electroencephalography (EEG) to detect AD and MCI. EEG rhythms were recorded from 37 AD patients, 37 MCI subjects and 37 HC subjects. Artifact-free trials were analyzed by means of several spectral and nonlinear features: relative power in the conventional frequency bands, median frequency, individual alpha frequency, spectral entropy, Lempel–Ziv complexity, central tendency measure, sample entropy, fuzzy entropy, and auto-mutual information. Relevance and redundancy analyses were also conducted through the fast correlation-based filter (FCBF) to derive an optimal set of them. The selected features were used to train three different models aimed at classifying the trials: linear discriminant analysis (LDA), quadratic discriminant analysis (QDA) and multi-layer perceptron artificial neural network (MLP). Afterwards, each subject was automatically allocated in a particular group by applying a trial-based majority vote procedure. After feature extraction, the FCBF method selected the optimal set of features: individual alpha frequency, relative power at delta frequency band, and sample entropy. Using the aforementioned set of features, MLP showed the highest diagnostic performance in determining whether a subject is not healthy (sensitivity of 82.35% and positive predictive value of 84.85% for HC vs. all classification task) and whether a subject does not suffer from AD (specificity of 79.41% and negative predictive value of 84.38% for AD vs. all comparison). Our findings suggest that our methodology can help physicians to discriminate AD, MCI and HC.

15 December 2017 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
Roberto HorneroRoberto Hornero
Roberto Hornero
LKLeila Kheirandish-Gozal
Leila Kheirandish-Gozal
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
MPMona F. Philby
Mona F. Philby
MAMaría Luz Alonso-Álvarez
María Luz Alonso-Álvarez
David GozalDavid Gozal
David Gozal
Rationale: The vast majority of children around the world undergoing adenotonsillectomy for obstructive sleep apnea–hypopnea syndrome (OSA) are not objectively diagnosed by nocturnal polysomnography because of access availability and cost issues. Automated analysis of nocturnal oximetry (nSpO2), which is readily and globally available, could potentially provide a reliable and convenient diagnostic approach for pediatric OSA. Methods: Deidentified nSpO2 recordings from a total of 4,191 children originating from 13 pediatric sleep laboratories around the world were prospectively evaluated after developing and validating an automated neural network algorithm using an initial set of single-channel nSpO2 recordings from 589 patients referred for suspected OSA. Measurements and Main Results: The automatically estimated apnea–hypopnea index (AHI) showed high agreement with AHI from conventional polysomnography (intraclass correlation coefficient, 0.785) when tested in 3,602 additional subjects. Further assessment on the widely used AHI cutoff points of 1, 5, and 10 events/h revealed an incremental diagnostic ability (75.2, 81.7, and 90.2% accuracy; 0.788, 0.854, and 0.913 area under the receiver operating characteristic curve, respectively). Conclusions: Neural network–based automated analyses of nSpO2 recordings provide accurate identification of OSA severity among habitually snoring children with a high pretest probability of OSA. Thus, nocturnal oximetry may enable a simple and effective diagnostic alternative to nocturnal polysomnography, leading to more timely interventions and potentially improved outcomes.

5 April 2018 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
ACAndrea Crespo
Andrea Crespo
FCFélix del Campo
Félix del Campo
Roberto HorneroRoberto Hornero
Roberto Hornero
Complexity, costs, and waiting lists issues demand a simplified alternative for sleep apnea-hypopnea syndrome (SAHS) diagnosis. The blood oxygen saturation signal (SpO $_{2}$ ) carries useful information about SAHS and can be easily acquired from overnight oximetry. In this study, SpO $_{2}$ single-channel recordings from 320 subjects were obtained at patients' home. They were used to automatically obtain statistical, spectral, non-linear, and clinical SAHS-related information. Relevant and non-redundant data from these analyses were subsequently used to train and validate four machine-learning methods with ability to classify SpO $_{2}$ signals into one out of the four SAHS-severity degrees (no-SAHS, mild, moderate, and severe). All the models trained (linear discriminant analysis, 1-vs-all logistic regression, Bayesian multi-layer perceptron, and AdaBoost), outperformed the diagnostic ability of the conventionally-used 3% oxygen desaturation index. An AdaBoost model built with linear discriminants as base classifiers reached the highest figures. It achieved 0.479 Cohen's a in the SAHS severity classification, as well as 92.9%, 87.4%, and 78.7% accuracies in binary classification tasks using increasing severity thresholds (apnea-hypopnea index: 5, 15, and 30 events/hour, respectively). These results suggest that machine learning can be used along with SpO $_{2}$ information acquired at patients' home to help in SAHS diagnosis simplification

5 August 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
FVFernando Vaquerizo-Villar
Fernando Vaquerizo-Villar
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
LKLeila Kheirandish-Gozal
Leila Kheirandish-Gozal
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
Verónica Barroso-GarcíaVerónica Barroso-García
Verónica Barroso-García
Roberto HorneroRoberto Hornero
Roberto Hornero
This study aims at assessing the usefulness of deep learning to enhance the diagnostic ability of oximetry in the context of automated detection of pediatric obstructive sleep apnea (OSA). A total of 3196 blood oxygen saturation (SpO 2 ) signals from children were used for this purpose. A convolutional neural network (CNN) architecture was trained using 20-min SpO 2 segments from the training set (859 subjects) to estimate the number of apneic events. CNN hyperparameters were tuned using Bayesian optimization in the validation set (1402 subjects). This model was applied to three test sets composed of 312, 392, and 231 subjects from three independent databases, in which the apnea-hypopnea index (AHI) estimated for each subject (AHI CNN ) was obtained by aggregating the output of the CNN for each 20-min SpO 2 segment. AHI CNN outperformed the 3% oxygen desaturation index (ODI3), a clinical approach, as well as the AHI estimated by a conventional feature-engineering approach based on multi-layer perceptron (AHI MLP ). Specifically, AHI CNN reached higher four-class Cohen's kappa in the three test databases than ODI3 (0.515 vs 0.417, 0.422 vs 0.372, and 0.423 vs 0.369) and AHI MLP (0.515 vs 0.377, 0.422 vs 0.381, and 0.423 vs 0.306). In addition, our proposal outperformed state-of-the-art studies, particularly for the AHI severity cutoffs of 5 e/h and 10 e/h. This suggests that the information automatically learned from the SpO 2 signal by deep-learning techniques helps to enhance the diagnostic ability of oximetry in the context of pediatric OSA.

15 April 2021 in Pediatric Pulmonology
Verified
Journal Article
Closed access
PDF file
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
LKLeila Kheirandish-Gozal
Leila Kheirandish-Gozal
FCFélix del Campo
Félix del Campo
David GozalDavid Gozal
David Gozal
Roberto HorneroRoberto Hornero
Roberto Hornero

24 March 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
ACAna Cerezo-Hernández
Ana Cerezo-Hernández
ACAndrea Crespo
Andrea Crespo
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
FVFernando Vaquerizo-Villar
Fernando Vaquerizo-Villar
FCFélix del Campo
Félix del Campo
The most appropriate physiological signals to develop simplified as well as accurate screening tests for obstructive sleep apnoea (OSA) remain unknown. This study aimed at assessing whether joint analysis of at-home oximetry and airflow recordings by means of machine-learning algorithms leads to a significant diagnostic performance increase compared to single-channel approaches. Consecutive patients showing moderate-to-high clinical suspicion of OSA were involved. The apnoea-hypopnoea index (AHI) from unsupervised polysomnography was the gold standard. Oximetry and airflow from at-home polysomnography were parameterised by means of 38 time, frequency, and non-linear variables. Complementarity between both signals was exhaustively inspected via automated feature selection. Regression support vector machines were used to estimate the AHI from single-channel and dual-channel approaches. A total of 239 patients successfully completed at-home polysomnography. The optimum joint model reached 0.93 (95%CI 0.90–0.95) intra-class correlation coefficient between estimated and actual AHI. Overall performance of the dual-channel approach (kappa: 0.71; 4-class accuracy: 81.3%) significantly outperformed individual oximetry (kappa: 0.61; 4-class accuracy: 75.0%) and airflow (kappa: 0.42; 4-class accuracy: 61.5%). According to our findings, oximetry alone was able to reach notably high accuracy, particularly to confirm severe cases of the disease. Nevertheless, oximetry and airflow showed high complementarity leading to a remarkable performance increase compared to single-channel approaches. Consequently, their joint analysis via machine learning enables accurate abbreviated screening of OSA at home.