Danut Cristian Urduza

Mr. Danut Cristian Urduza


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2025 in Axioms
Verified
Journal Article
Open access
PDF file
Danut Cristian UrduzaDanut Cristian Urduza
Danut Cristian Urduza
Lavinia GROSULavinia GROSU
Lavinia GROSU
Adalia Andreea PercembliAdalia Andreea Percembli
Adalia Andreea Percembli
AȘAlexandru Șerban
Alexandru Șerban
Alexandru DobrovicescuAlexandru Dobrovicescu
Alexandru Dobrovicescu
Air liquefaction systems are essential in cryogenic engineering and energy storage, yet their performance is often constrained by significant exergy destruction. This study develops an exergy-based assessment of the Linde–Hampson air liquefaction cycle to identify dominant sources of inefficiency and explore strategies for improvement. The analysis shows that throttling (≈41%) and compression (≈40%) represent the major contributions to exergy losses, followed by finite-temperature heat transfer (≈15%) in the recuperative heat exchanger. To mitigate these losses, fractional throttling and optimized inlet conditions are proposed, leading to reduced compressor work and improved overall efficiency. A comparative study of a two-stage throttling configuration demonstrates a decrease in throttling-related exergy destruction to approximately 30%. Reverse Pinch analysis is employed to verify the thermal coupling of hot and cold streams and to determine the minimum feasible temperature difference. The design optimization of the recuperative heat exchanger identifies an optimal velocity ratio that minimizes pressure losses and quantifies how compression pressure affects the required heat transfer surface area. The results provide a systematic framework for improving the thermodynamic performance of air liquefaction cycles, highlighting exergy analysis as a powerful tool for guiding structural modifications and functional optimization.

21 January 2026 in Entropy
Verified
Journal Article
Open access
PDF file
Danut Cristian UrduzaDanut Cristian Urduza
Danut Cristian Urduza
Lavinia GROSULavinia GROSU
Lavinia GROSU
ASAlexandru Serban
Alexandru Serban
Adalia Andreea PercembliAdalia Andreea Percembli
Adalia Andreea Percembli
Alexandru DobrovicescuAlexandru Dobrovicescu
Alexandru Dobrovicescu
In cryogenic air liquefaction systems, a major share of the mechanical energy consumption is associated with exergy destruction caused by heat transfer in recuperative heat exchangers. This study investigated the exergetic optimization of cryogenic gas separation systems by focusing on the Claude–Heylandt cycle as an advanced structural modification of the classical Linde–Hampson scheme. An exergy-based analysis demonstrates that minimizing mechanical energy consumption requires a progressive reduction in the temperature difference between the hot forward stream and the cold returning stream toward the cold end of the heat exchanger. This condition was achieved by extracting a fraction of the high-pressure stream and expanding it in a parallel expander, thereby creating a controlled imbalance in the heat capacities between the two streams. The proposed configuration reduces the share of exergy destruction associated with heat transfer in the recuperative heat exchanger from 14% to 3.5%, leading to a fourfold increase in the exergetic efficiency, together with a 3.6-fold increase in the liquefied air fraction compared with the Linde–Hampson cycle operating under identical conditions. The effects of key decision parameters, including the compression pressure, imposed temperature differences, and expander inlet temperature, were systematically analyzed. The study was further extended by integrating an air separation column into the Claude–Heylandt cycle and optimizing its configuration based on entropy generation minimization. The optimal liquid-air feeding height and threshold number of rectification trays were identified, beyond which further structural complexity yielded no thermodynamic benefit. The results highlight the effectiveness of exergy-based optimization as a unified design criterion for both cryogenic liquefaction and separation processes.

21 August 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
Adalia Andreea PercembliAdalia Andreea Percembli
Adalia Andreea Percembli
Lavinia GROSULavinia GROSU
Lavinia GROSU
Danut Cristian UrduzaDanut Cristian Urduza
Danut Cristian Urduza
Alexandru DobrovicescuAlexandru Dobrovicescu
Alexandru Dobrovicescu
Liquid Air Energy Storage (LAES) is a promising large-scale storage technology for supporting the sustainable integration of intermittent renewable electricity into power grids, particularly when electricity storage is combined with waste-heat valorization, cryogenic cold recovery, and reduced exergy degradation. In this thermodynamic sense, the present study proposes a sustainability-oriented framework for the comparative and parametric exergetic analysis of LAES systems, integrating the liquefaction and discharge stages within a unified analysis. The assessment focuses on thermodynamic resource efficiency and exergy performance rather than on a complete economic, environmental, or life-cycle evaluation. The objective is to identify the components and operating parameters that most strongly influence performance and to quantify the reductions in exergy destruction and losses achieved through configuration changes and parameter variation. Three Linde–Hampson-based liquefaction configurations are compared, including arrangements with external and intermediate auxiliary pre-cooling. Improved heat-exchanger integration and temperature matching increase the structural liquefaction exergetic indicator from 7.95% in the baseline configuration to 19.28% in the two-RHX configuration. The discharge stage is assessed parametrically with respect to cryogenic pumping pressure, turbine inlet temperature, and expansion architecture. Single-stage and two-stage adiabatic expansions are compared with an ideal isothermal benchmark. The adiabatic configurations provide mechanical-work recovery together with recoverable cooling potential, whereas the isothermal case gives the highest work-recovery benchmark. Under the reference conditions, using the aggregated compressor representation adopted for the main parametric analysis, the two-stage adiabatic configuration reaches a global exergetic efficiency of 15.92% for the improved Linde–Hampson-based chain and 24.87% for the selected Claude–Heylandt reference block.