Alexandru Dobrovicescu

Prof. Dr. Alexandru Dobrovicescu

University Politehnica of Bucharest
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
AAAltayyeb Alfaryjat
Altayyeb Alfaryjat
LMLucian Miron
Lucian Miron
HPHoratiu Pop
Horatiu Pop
VAValentin Apostol
Valentin Apostol
MSMariana-Florentina Stefanescu
Mariana-Florentina Stefanescu
Alexandru DobrovicescuAlexandru Dobrovicescu
Alexandru Dobrovicescu
A modern computer generates a great amount of heat while working. In order to secure appropriate working conditions by extracting the heat, a specific mechanism should be used. This research paper presents the effect of nanofluids on the microchannel heat sink performance of computer cooling systems experimentally. CeO2, Al2O3 and ZrO2 nanoparticles suspended in 20% ethylene glycol and 80% distilled water are used as working fluids in the experiment. The concentration of the nanoparticles ranges from 0.5% to 2%, mass flow rate ranges from 0.028 kg/s to 0.084 kg/s, and the ambient temperature ranges from 25 °C to 40 °C. Regarding the thermal component, parameters such as thermophysical properties of the nanofluids and base fluids, central processing unit (CPU) temperature, heat transfer coefficient, pressure drop, and pumping power have been experimentally investigated. The results show that CeO2-EG/DW, at a concentration of 2% and a mass flow rate of 0.084 kg/s, has with 8% a lower temperature than the other nanofluids and with 29% a higher heat transfer coefficient compared with the base fluid. The Al2O3-EG/DW shows the lowest pressure drop and pumping power, while the CeO2-EG/DW and ZrO2-EG/DW show the highest. However, a slight increase of pumping power and pressure drop can be accepted, considering the high improvement that the nanofluid brings in computer cooling performance compared to the base fluid.

13 February 2022 in Entropy
Verified
Journal Article
Open access
PDF file
SBSorin Bucsa
Sorin Bucsa
ASAlexandru Serban
Alexandru Serban
MBMugur C. Balan
Mugur C. Balan
ICIonita Claudia
Ionita Claudia
GNGabriel Nastase
Gabriel Nastase
Alexandru DobrovicescuAlexandru Dobrovicescu
Alexandru Dobrovicescu
This case study analyzes a cryogenic air separation unit (ASU) with a production of V˙O2=58,300 [m3Nh] of gaseous oxygen with a concentration greater than 98.5%, operating in Romania on a steel plant platform. The goal of the paper is to provide an extensive model of exergetic analysis that could be used in an optimization procedure when decisional parameters are changed or structural design modifications are implemented. For each key part of the Air Separation Unit, an exergetic product and fuel were defined and, based on their definition, the coefficient of performance of each functional zone was calculated. The information about the magnitude of the exergetic losses offers solutions for their future recovery. The analysis of the exergy destructions suggests when it is worth making a larger investment. The exergetic analysis of the compression area of the ASU points out an exergy destruction and loss of 37% from the total plant’s electrical energy input. The exergy loss with the heat transferred to the cooling system of compressors can be recovered; for the exergy destruction portion, the challenge between investment and operating costs should be considered. The exergy destruction of the air separation columns found the High Pressure Column (HPC) to be more destructive than the Low Pressure Column. The share of the exergy destruction in the total plant’s electrical energy input is 8.3% for the HPC. The local COP of the HPC, calculated depending on the total exergy of the local product and fuel, is 62.66%. The calculus of the air separation column is performed with the ChemSep simulator.

30 September 2023 in Energy
Verified
Journal Article
Closed access
DHDaniel P. Hiris
Daniel P. Hiris
OPOctavian G. Pop
Octavian G. Pop
Alexandru DobrovicescuAlexandru Dobrovicescu
Alexandru Dobrovicescu
Mircea Cristian DudescuMircea Cristian Dudescu
Mircea Cristian Dudescu
MBMugur C. Balan
Mugur C. Balan

19 March 2021 in Entropy
Verified
Journal Article
Open access
PDF file
CDCatalina Dobre
Catalina Dobre
Lavinia GROSULavinia GROSU
Lavinia GROSU
Alexandru DobrovicescuAlexandru Dobrovicescu
Alexandru Dobrovicescu
CGChisiu Georgiana
Chisiu Georgiana
Constantin MihaelaConstantin Mihaela
Constantin Mihaela
The purpose of the study is to show that two simple models that take into account only the irreversibility due to temperature difference in the heat exchangers and imperfect regeneration are able to indicate refrigerating machine behavior. In the present paper, the finite physical dimensions thermodynamics (FPDT) method and 0-D modeling using the Schmidt model with imperfect regeneration were applied in the study of a β type Stirling refrigeration machine.The 0-D modeling is improved by including the irreversibility caused by imperfect regeneration and the finite temperature difference between the gas and the heat exchangers wall. A flowchart of the Stirling refrigerator exergy balance is presented to show the internal and external irreversibilities. It is found that the irreversibility at the regenerator level is more important than that at the heat exchangers level. The energies exchanged by the working gas are expressed according to the practical parameters, necessary for the engineer during the entire project. The results of the two thermodynamic models are presented in comparison with the experimental results, which leads to validation of the proposed FPDT model for the functional and constructive parameters of the studied refrigerating machine.

1 August 2015 in Applied Thermal Engineering
Verified
Journal Article
Closed access
AGAdina Teodora Gheorghian
Adina Teodora Gheorghian
Alexandru DobrovicescuAlexandru Dobrovicescu
Alexandru Dobrovicescu
Luminita PopescuLuminita Popescu
Luminita Popescu
Mihai CruceruMihai Cruceru
Mihai Cruceru
Bogdan DiaconuBogdan Diaconu
Bogdan Diaconu

24 May 2022 in Entropy
Verified
Journal Article
Open access
PDF file
ICIonita Claudia
Ionita Claudia
SBSorin Bucsa
Sorin Bucsa
ASAlexandru Serban
Alexandru Serban
CDCatalina Dobre
Catalina Dobre
Alexandru DobrovicescuAlexandru Dobrovicescu
Alexandru Dobrovicescu
The use of organic Rankine cycles (ORCs) is a viable solution for the recovery of waste heat. For an air separation unit (ASU) with a production of V˙O2=58300mN3/h operating in Romania, the value of utilization of the heat transferred to the cooling system of the compression area represents 21% of the global system electrical energy input. To recover this thermal energy and transform it into mechanical energy, an ORC system was proposed. To maximize the production of mechanical power, an exergy analysis was performed. Exergy analysis was used to choose the most suitable organic fluid and find the optimum constructive structure of the Rankine cycle. The calculation of the exergy destruction in the key apparatuses of the system allowed investigation into the optimization search procedure. The large exergy destruction in the liquid preheater suggested the decrease in the temperature difference in this part of the evaporator by increasing the inlet temperature of the liquid; and an internal recuperative heat exchanger was used for this purpose. When permitted, the overheating of the vapors also reduced the temperature difference between the heat source and the organic fluid during the heat transfer process. The analysis was comparatively performed for several organic fluids such as R-245fa, R123, n-pentane and R717. The use of ammonia, that offered the possibility of superheating the vapors at the turbine inlet, brought a gain of mechanical power corresponding to 6% economy in the electrical energy input of the global plant.