Cheng Chen

Dr. Cheng Chen


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MWMin Wang
Min Wang
WSWenqi Shi
Wenqi Shi
JZJianyu Zhang
Jianyu Zhang
JCJiarong Chen
Jiarong Chen
QLQingliang Lin
Qingliang Lin
GWGuoxing Wang
Guoxing Wang
Cardiovascular disease (CVD) remains the leading cause of global mortality, highlighting the need for continuous vital sign monitoring. Photoplethysmography (PPG) is well suited for wearable devices. Smart rings, benefiting from dense capillary distribution and minimal tissue interference, can capture high-quality PPG signals with comfort, making them a promising next-generation wearable. However, ring rotation relative to the finger alters the optical path, especially for multi-wavelength light, thus reducing accuracy. This paper proposes a rotation-robust PPG sensor for smart rings. Monte Carlo simulations analyze photon transmission under different LED–photodiode (PD) angles, showing that at ±60°, green, red, and infrared light achieve optimal penetration into the microcirculation layer. Considering non-ideal conditions, the green-light angle is adjusted to ±30°, and a symmetrical sensor design is adopted. A prototype smart ring is developed, capable of recording 4-channel PPG, 3-axis acceleration, and 4-channel temperature signals at 100, 25, and 0.2 Hz, respectively. The system achieves reliable PPG acquisition with only 0.59 mA average current consumption. In continuous testing, heart rate estimation reached mean absolute errors of 0.82, 0.79, and 0.78 bpm for green, red, and IR light. The results provide a reference for future smart ring development.

19 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
JZJianyu Zhang
Jianyu Zhang
ZLZhizhang Li
Zhizhang Li
MWMin Wang
Min Wang
LLLin Luohan
Lin Luohan
GWGuoxing Wang
Guoxing Wang
CCCheng Chen
Cheng Chen
Noninvasive blood glucose monitoring has long been a critical research focus in diabetes management. Among emerging technologies, photoacoustic sensing, combining the molecular specificity with deep penetration, has garnered significant attention. It offers rapid response and pain-free operation, making it a strong candidate for next-generation portable blood glucose monitoring devices. This review systematically traces the development and current state of photoacoustic glucose sensing, with a particular focus on the selection and optimization of core system components. It also summarizes common interference in glucose detection and outlines strategies for their mitigation, along with signal processing and signal-to-noise ratio enhancement techniques suitable for real-world applications. Addressing the growing demand for wearable continuous glucose monitors, this work analyzes the key challenges in system integration and outlines recent advances in enabling technologies. It proposes multi-technology integration approaches to bridge the gap between photoacoustic sensing and microsystem design, offering theoretical foundations and practical guidance for future research on wearable photoacoustic systems.

28 August 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
SZShuo Zhang
Shuo Zhang
KXKangkang Xu
Kangkang Xu
NZNan Zeng
Nan Zeng
JSJiansong Sun
Jiansong Sun
QYQianrui Yang
Qianrui Yang
CCCheng Chen
Cheng Chen
Wearable near-infrared spectroscopy (NIRS) enables non-invasive hemodynamic monitoring, yet conventional CW-NIRS systems suffer from limited temporal resolution, scalp-only measurement, and mandatory manual tuning to compensate for optical heterogeneity across subjects and sites. This work develops NIRSLINK, a modular cascaded wearable NIRS system for high-speed multi-site hemodynamic acquisition. Its flexible probes adopt spring-floating optics with a standardized 30 mm optode separation, integrating dual 735/850 nm LEDs, silicon photodiodes, and a two-stage closed-loop tuning algorithm. A single probe achieves a peak sampling rate of 3 kHz, and up to eight cascaded probes form 52 valid channels, with a signal-to-noise ratio (SNR) of 78.61 ± 7.03 dB and an optical dynamic range (DR) of 101.32 ± 12.41 dB. Phantom experiments verify its millisecond temporal resolution and high sensitivity to blood flow and hemoglobin variations. In vivo trials, including the Valsalva maneuver, forearm occlusion, and two-back cognitive tasks, demonstrate simultaneous recording of hemoglobin concentration shifts, pulse waveforms, and beat-to-beat pulse transit times (PTTs). NIRSLINK supports hemodynamic measurements across multiple anatomical locations, including the forehead, forearm, upper arm, and thigh, covering both cranial and peripheral body regions. The embedded auto-tuning module stabilizes signals from the forehead, forearm, and other regions within the optimal ADC range without manual adjustment, preventing signal saturation and SNR degradation. This scalable adaptive platform overcomes critical drawbacks of traditional wearable NIRS, applicable to cognitive neuroscience, non-invasive cardiovascular assessment, and ambulatory physiological monitoring, and provides design references for multi-site optical sensors.

21 July 2026 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
JCJiarong Chen
Jiarong Chen
BLBin Liu
Bin Liu
WSWenqi Shi
Wenqi Shi
MWMin Wang
Min Wang
RGRuize Gao
Ruize Gao
CCCheng Chen
Cheng Chen
Wearable photoplethysmography (PPG) enables non-invasive cardiovascular monitoring, but most systems rely on single-site measurements and rarely test whether signals are spatially homogeneous across limbs. Here, we built a large-scale bilateral ring-PPG benchmark comprising 97,559 valid samples from 1810 participants with synchronized measurements from both hands. Bilateral averaged predictions showed target-dependent performance, with mean absolute errors of 3.21 bpm for heart rate (HR), 12.36 mmHg for systolic blood pressure (SBP), 8.21 mmHg for diastolic blood pressure (DBP), and 9.46 years for age. Relative to a cohort-mean baseline, HR showed the clearest improvement (10.65–3.21 bpm), whereas age improved more modestly (11.08–9.46 years). BP estimation performance remained limited, with MAE reductions from 13.81 to 12.36 mmHg for SBP and from 9.27 to 8.21 mmHg for DBP, while error dispersions remained close to target variability. Similar trends across 12 backbones suggested that the pattern was not architecture-specific. Samples with smaller bilateral differences further reduced HR MAE by 19.3%. Together, these findings establish a bilateral wearable PPG benchmark with strongest utility for HR, cautious utility for age, and limited, transparently quantified BP performance.