Min Wang

Mr. Min Wang

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MWMin Wang
Min Wang
ZLZhe Li
Zhe Li
QZQirui Zhang
Qirui Zhang
GWGuoxing Wang
Guoxing Wang
With photoplethysmograph (PPG) sensors showing increasing potential in wearable health monitoring, the challenging problem of motion artifact (MA) removal during intensive exercise has become a popular research topic. In this study, a novel method that combines heart rate frequency (HRF) estimation and notch filtering is proposed. The proposed method applies a cascaded adaptive noise cancellation (ANC) based on the least mean squares (LMS)-Newton algorithm for preliminary motion artifacts reduction, and further adopts special heart rate frequency tracking and correction schemes for accurate HRF estimation. Finally, notch filters are employed to restore the PPG signal with estimated HRF based on its quasi-periodicity. On an open source data set that features intensive running exercise, the proposed method achieves a competitive mean average absolute error (AAE) result of 0.92 bpm for HR estimation. The practical experiments are carried out with the PPG evaluation platform developed by ourselves. Under three different intensive motion patterns, a 0.89 bpm average AAE result is achieved with the average correlation coefficient between recovered PPG signal and reference PPG signal reaching 0.86. The experimental results demonstrate the effectiveness of the proposed method for accurate HR estimation and robust MA removal in PPG during intensive exercise.

13 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MWMin Wang
Min Wang
WSWenqi Shi
Wenqi Shi
JZJianyu Zhang
Jianyu Zhang
JCJiarong Chen
Jiarong Chen
QLQingliang Lin
Qingliang Lin
GWGuoxing Wang
Guoxing Wang
Cardiovascular disease (CVD) remains the leading cause of global mortality, highlighting the need for continuous vital sign monitoring. Photoplethysmography (PPG) is well suited for wearable devices. Smart rings, benefiting from dense capillary distribution and minimal tissue interference, can capture high-quality PPG signals with comfort, making them a promising next-generation wearable. However, ring rotation relative to the finger alters the optical path, especially for multi-wavelength light, thus reducing accuracy. This paper proposes a rotation-robust PPG sensor for smart rings. Monte Carlo simulations analyze photon transmission under different LED–photodiode (PD) angles, showing that at ±60°, green, red, and infrared light achieve optimal penetration into the microcirculation layer. Considering non-ideal conditions, the green-light angle is adjusted to ±30°, and a symmetrical sensor design is adopted. A prototype smart ring is developed, capable of recording 4-channel PPG, 3-axis acceleration, and 4-channel temperature signals at 100, 25, and 0.2 Hz, respectively. The system achieves reliable PPG acquisition with only 0.59 mA average current consumption. In continuous testing, heart rate estimation reached mean absolute errors of 0.82, 0.79, and 0.78 bpm for green, red, and IR light. The results provide a reference for future smart ring development.

19 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
JZJianyu Zhang
Jianyu Zhang
ZLZhizhang Li
Zhizhang Li
MWMin Wang
Min Wang
LLLin Luohan
Lin Luohan
GWGuoxing Wang
Guoxing Wang
CCCheng Chen
Cheng Chen
Noninvasive blood glucose monitoring has long been a critical research focus in diabetes management. Among emerging technologies, photoacoustic sensing, combining the molecular specificity with deep penetration, has garnered significant attention. It offers rapid response and pain-free operation, making it a strong candidate for next-generation portable blood glucose monitoring devices. This review systematically traces the development and current state of photoacoustic glucose sensing, with a particular focus on the selection and optimization of core system components. It also summarizes common interference in glucose detection and outlines strategies for their mitigation, along with signal processing and signal-to-noise ratio enhancement techniques suitable for real-world applications. Addressing the growing demand for wearable continuous glucose monitors, this work analyzes the key challenges in system integration and outlines recent advances in enabling technologies. It proposes multi-technology integration approaches to bridge the gap between photoacoustic sensing and microsystem design, offering theoretical foundations and practical guidance for future research on wearable photoacoustic systems.

1 September 2019 in SID Symposium Digest of Technical Papers
Verified
Journal Article
Closed access
PDF file
QCQuanming Chen
Quanming Chen
ZPZenghui Peng
Zenghui Peng
Yan LiYan Li
Yan Li
Shuxin LiuShuxin Liu
Shuxin Liu
PZPengcheng Zhou
Pengcheng Zhou
YSYikai Su
Yikai Su