Shaun Davidson

Dr. Shaun Davidson

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2020 in Critical Care
Verified
Journal Article
Open access
PDF file
SDShaun Davidson
Shaun Davidson
MVMauricio Villarroel
Mauricio Villarroel
MHMirae Harford
Mirae Harford
EFEoin Finnegan
Eoin Finnegan
JJJoao Jorge
Joao Jorge
LTLionel Tarassenko
Lionel Tarassenko
Background: Circadian deregulation in patients treated in an intensive care unit (ICU) is commonplace and is associated with complications such as immune system disruption and delirium. The presence and nature of circadian rhythms in the vital signs recorded in the ICU are not well documented, nor is their generalisability across different ICU populations. This paper investigates the presence of circadian rhythms in the 24 h prior to discharge from an ICU of patients who subsequently recovered. We hypothesise that vital-sign circadian rhythms will be observable in this cohort of patients, that these circadian rhythms will resemble known behaviour in healthy individuals, and that these circadian rhythms will be generalisable across different populations of ICU patients. Methods: Circadian rhythms are investigated across several commonly measured vital signs: systolic blood pressure, heart rate, respiratory rate, and temperature. The data employed in this paper are from patients in the MIMIC-III (2001-2012), eICU-CRD (2014-2015), and PICRAM (2009-2015) databases, spanning 198,205 patients across 211 hospitals in the USA and the UK. Evaluation of circadian rhythms encompasses a comparison between the observed rhythm profiles and peak-nadir excursions with those found in the literature, as well as the assessment of the correlation in rhythm profiles between databases. Results: Circadian patterns in all four vital signs were found to conform to those reported for non-ICU cohorts. Additionally, all vital-sign circadian profiles were correlated between databases at the p = 0.05 level. The peak-nadir excursion in the observed rhythms was suppressed by a factor of 2-5 relative to results found in the literature for cohorts of young, healthy individuals. Conclusions: Across three different ICU datasets, systolic blood pressure, heart rate, respiratory rate, and temperature showed circadian variation in the 24 h prior to discharge from an ICU. However, the amplitude of these variations was markedly reduced in comparison to cohorts of young, healthy adults. The observed circadian variation correlated strongly between databases, suggesting there is a generalisable state of circadian behaviour in ICU patients during (Continued on next page)

22 October 2019 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
VUVincent Uyttendaele
Vincent Uyttendaele
JKJennifer L. Knopp
Jennifer L. Knopp
SDShaun Davidson
Shaun Davidson
TDThomas Desaive
Thomas Desaive
Balázs BenyóBalázs Benyó
Balázs Benyó
JCJ. Geoffrey Chase
J. Geoffrey Chase
Background: The challenges of glycaemic control in critically ill patients have been debated for 20 years. While glycaemic control shows benefits inter- and intra-patient metabolic variability results in increased hypoglycaemia and glycaemic variability, both increasing morbidity and mortality. Hence, current recommendations for glycaemic control target higher glycaemic ranges, guided by the fear of harm. Lately, studies have proven the ability to provide safe, effective control for lower, normoglycaemic, ranges, using model-based computerised methods. Such methods usually identify patient-specific physiological parameters to personalize titration of insulin and/or nutrition. The Stochastic-Targeted (STAR) glycaemic control framework uses patient-specific insulin sensitivity and a stochastic model of its future variability to directly account for both inter- and intra-patient variability in a risk-based insulin-dosing approach. Results: In this study, a more personalized and specific 3D version of the stochastic model used in STAR is compared to the current 2D stochastic model, both built using kernel-density estimation methods. Fivefold cross validation on 681 retrospective patient glycaemic control episodes, totalling over 65,000 h of control, is used to determine whether the 3D model better captures metabolic variability, and the potential gain in glycaemic outcome is assessed using validated virtual trials. Results show that the 3D stochastic model has similar forward predictive power, but provides significantly tighter, more patient-specific, prediction ranges, showing the 2D model over-conservative > 70% of the time. Virtual trial results show that overall glycaemic safety and performance are similar, but the 3D stochastic model reduced median blood glucose levels (6.3 [5.7, 7.0] vs. 6.2 [5.6, 6.9]) with a higher 61% vs. 56% of blood glucose within the 4.4–6.5 mmol/L range. Conclusions: This improved performance is achieved with higher insulin rates and higher carbohydrate intake, but no loss in safety from hypoglycaemia. Thus, the 3D stochastic model developed better characterises patient-specific future insulin sensitivity dynamics, resulting in improved simulated glycaemic outcomes and a greater level of personalization in control. The results justify inclusion into ongoing clinical use of STAR.

1 September 2018 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
JBJoel Cameron Balmer
Joel Cameron Balmer
CPChristopher G Pretty
Christopher G Pretty
SDShaun Davidson
Shaun Davidson
TDThomas Desaive
Thomas Desaive
SKShun Kamoi
Shun Kamoi
JCJ Geoffrey Chase
J Geoffrey Chase
Objective : Pulse wave velocity measurements are an indicator of arterial stiffness and possible cardiovascular dysfunction. It is usually calculated by measuring the pulse transit time (PTT) over a known distance through the arteries. In animal studies, reliable PTT measures can be obtained using two pressure catheters. However, such direct, invasive methods are undesirable in clinical settings. A less invasive alternative measure of PTT is pulse arrival time (PAT), the time between the Q-wave of an electrocardiogram (ECG) and the arrival of the foot of the beats pressure waveform at one pressure catheter. Since the Q-wave signifies the start of ventricular contraction, PAT includes the pre-ejection period (PEP), a time where no blood is ejected. Thus, inter- or intra- subject variation in PEP could result in poor correlation between pulse arrival time (PAT) and the desired pulse transit time (PTT). Approach : This study looks at the relationship between PAT and PTT, over a range of common critical care therapies and determines the effect of PEP on PAT as a possible surrogate of PTT in a critical care environment. The analysis uses data from five porcine experiments, where ECG, aortic arch and abdominal aortic pressure were measured simultaneously, over a range of induced hemodynamic conditions. Results : The resulting correlations of PAT verse PTT varied within pigs and across interventions ( r 2 = 0.32–0.69), and across pigs ( r 2 = 0.05–0.60). Variability was due to three main causes. First, the interventions themselves effect PEP and PTT differently, second, pig specific response to the interventions, and third, inter- and intra- pig variability in PEP, independent of PTT. Significance : The overall analysis shows PAT is an unreliable measure of PTT and a poor surrogate under clinical interventions common in a critical care setting, due to intra- and inter- subject variability in PEP.

22 April 2021 in Critical Care
Verified
Journal Article
Open access
PDF file
SDShaun Davidson
Shaun Davidson
MVMauricio Villarroel
Mauricio Villarroel
MHMirae Harford
Mirae Harford
EFEoin Finnegan
Eoin Finnegan
JJJoão Jorge
João Jorge
LTLionel Tarassenko
Lionel Tarassenko
Background: Disrupted vital-sign circadian rhythms in the intensive care unit (ICU) are associated with complications such as immune system disruption, delirium and increased patient mortality. However, the prevalence and extent of this disruption is not well understood. Tools for its detection are currently limited.Methods: This paper evaluated and compared vital-sign circadian rhythms in systolic blood pressure, heart rate, respiratory rate and temperature. Comparisons were made between the cohort of patients who recovered from the ICU and those who did not, across three large, publicly available clinical databases. This comparison included a qualitative assessment of rhythm profiles, as well as quantitative metrics such as peak–nadir excursions and correlation to a demographically matched ‘recovered’ profile.Results: Circadian rhythms were present at the cohort level in all vital signs throughout an ICU stay. Peak–nadir excursions and correlation to a ‘recovered’ profile were typically greater throughout an ICU stay in the cohort of patients who recovered, compared to the cohort of patients who did not.Conclusions: These results suggest that vital-sign circadian rhythms are typically present at the cohort level throughout an ICU stay and that quantitative assessment of these rhythms may provide information of prognostic use in the ICU.

24 April 2017 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
SKShun Kamoi
Shun Kamoi
CPChristopher Pretty
Christopher Pretty
JBJoel Balmer
Joel Balmer
SDShaun Davidson
Shaun Davidson
APAntoine Pironet
Antoine Pironet
JCJ. Geoffrey Chase
J. Geoffrey Chase
Pressure contour analysis is commonly used to estimate cardiac performance for patients suffering from cardiovascular dysfunction in the intensive care unit. However, the existing techniques for continuous estimation of stroke volume (SV) from pressure measurement can be unreliable during hemodynamic instability, which is inevitable for patients requiring significant treatment. For this reason, pressure contour methods must be improved to capture changes in vascular properties and thus provide accurate conversion from pressure to flow. This paper presents a novel pressure contour method utilizing pulse wave velocity (PWV) measurement to capture vascular properties. A three-element Windkessel model combined with the reservoir–wave concept are used to decompose the pressure contour into components related to storage and flow. The model parameters are identified beat-to-beat from the water-hammer equation using measured PWV, wave component of the pressure, and an estimate of subject-specific aortic dimension. SV is then calculated by converting pressure to flow using identified model parameters. The accuracy of this novel method is investigated using data from porcine experiments (N = 4 Pietrain pigs, 20–24.5 kg), where hemodynamic properties were significantly altered using dobutamine, fluid administration, and mechanical ventilation. In the experiment, left ventricular volume was measured using admittance catheter, and aortic pressure waveforms were measured at two locations, the aortic arch and abdominal aorta. Bland–Altman analysis comparing gold-standard SV measured by the admittance catheter and estimated SV from the novel method showed average limits of agreement of ±26% across significant hemodynamic alterations. This result shows the method is capable of estimating clinically acceptable absolute SV values according to Critchely and Critchely. The novel pressure contour method presented can accurately estimate and track SV even when hemodynamic properties are significantly altered. Integrating PWV measurements into pressure contour analysis improves identification of beat-to-beat changes in Windkessel model parameters, and thus, provides accurate estimate of blood flow from measured pressure contour. The method has great potential for overcoming weaknesses associated with current pressure contour methods for estimating SV.

25 November 2019 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
LMLiam Murphy
Liam Murphy
SDShaun Davidson
Shaun Davidson
JCJ. Geoffrey Chase
J. Geoffrey Chase
JKJennifer L. Knopp
Jennifer L. Knopp
TZTony Zhou
Tony Zhou
TDThomas Desaive
Thomas Desaive