Patrick Gladding

Dr. Patrick Gladding


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SGSarah Gleeson
Sarah Gleeson
YLYi-Wen Liao
Yi-Wen Liao
CDClementina Dugo
Clementina Dugo
ACAndrew Cave
Andrew Cave
LZLifeng Zhou
Lifeng Zhou
PGPatrick Gladding
Patrick Gladding
Increased spatial QRS-T angle has been shown to predict appropriate implantable cardioverter defibrilIator (ICD) therapy in patients with left ventricular systolic dysfunction (LVSD). We performed a retrospective cohort study in patients with left ventricular ejection fraction (LVEF) 31–40% to assess the relationship between the spatial QRS-T angle and other advanced ECG (A-ECG) as well as echocardiographic metadata, with all-cause mortality or ICD implantation for secondary prevention. 534 patients ≤75 years of age with LVEF 31–40% were identified through an echocardiography reporting database. Digital 12-lead ECGs were retrospectively matched to 295 of these patients, for whom echocardiographic and A-ECG metadata were then generated. Data mining was applied to discover novel ECG and echocardiographic markers of risk. Machine learning was used to develop a model to predict possible outcomes. 49 patients (17%) had events, defined as either mortality (n = 16) or ICD implantation for secondary prevention (n = 33). 72 parameters (58 A-ECG, 14 echocardiographic) were univariately different (p<0.05) in those with vs. without events. After adjustment for multiplicity, 24 A-ECG parameters and 3 echocardiographic parameters remained different (p<2x10-3). These included the posterior-to-leftward QRS loop ratio from the derived vectorcardiographic horizontal plane (previously associated with pulmonary artery pressure, p = 2x10-6); spatial mean QRS-T angle (134 vs. 112°, p = 1.6x10-4); various repolarisation vectors; and a previously described 5-parameter A-ECG score for LVSD (p = 4x10-6) that also correlated with echocardiographic global longitudinal strain (R2 = - 0.51, P < 0.0001). A spatial QRS-T angle >110° had an adjusted HR of 3.4 (95% CI 1.6 to 7.4) for secondary ICD implantation or all-cause death and adjusted HR of 4.1 (95% CI 1.2 to 13.9) for future heart failure admission. There was a loss of complexity between A-ECG and echocardiographic variables with an increasing degree of disease. Spatial QRS-T angle >110° was strongly associated with arrhythmic events and all-cause death. Deep analysis of global ECG and echocardiographic metadata revealed underlying relationships, which otherwise would not have been appreciated. Delivered at scale such techniques may prove useful in clinical decision making in the future.

Verified
Journal Article
Open access
PDF file
PGPatrick Gladding
Patrick Gladding
ACAndrew Cave
Andrew Cave
MZMehran Zareian
Mehran Zareian
KSKevin Smith
Kevin Smith
JHJagir Hussan
Jagir Hussan
TSTodd Schlegel
Todd Schlegel
It is undeniable that the increasing costs in healthcare are a concern. Although technological advancements have been made in healthcare systems, the return on investment made by governments and payers has been poor. The current model of care is unsustainable and is due for an upgrade. In developed nations, a law of diminishing returns has been noted in population health standards, whilst in the developing world, westernized chronic illnesses, such as diabetes and cardiovascular disease have become emerging problems. The reasons for these trends are complex, multifactorial and not easily reversed. Personalized medicine has the potential to have a significant impact on these issues, but for it to be truly successful, interdisciplinary mass collaboration is required. We propose here a vision for open-access advanced analytics for personalized cardiac diagnostics using imaging, electrocardiography and genomics.

1 January 2013 in Theranostics
Verified
Journal Article
Open access
FEFolarin Erogbogbo
Folarin Erogbogbo
JMJasmine May
Jasmine May
MSMak T Swihart
Mak T Swihart
PPParas N. Prasad
Paras N. Prasad
KSKatie Smart
Katie Smart
PGPatrick Gladding
Patrick Gladding
Metabolomic profiling is ideally suited for the analysis of cardiac metabolism in healthy and diseased states. Here, we show that systematic discovery of biomarkers of ischemic preconditioning using metabolomics can be translated to potential nanotheranostics. Thirty-three patients underwent percutaneous coronary intervention (PCI) after myocardial infarction. Blood was sampled from catheters in the coronary sinus, aorta and femoral vein before coronary occlusion and 20 minutes after one minute of coronary occlusion. Plasma was analysed using GC-MS metabolomics and iTRAQ LC-MS/MS proteomics. Proteins and metabolites were mapped into the Metacore network database (GeneGo, MI, USA) to establish functional relevance. Expression of 13 proteins was significantly different (p<0.05) as a result of PCI. Included amongst these was CD44, a cell surface marker of reperfusion injury. Thirty-eight metabolites were identified using a targeted approach. Using PCA, 42% of their variance was accounted for by 21 metabolites. Multiple metabolic pathways and potential biomarkers of cardiac ischemia, reperfusion and preconditioning were identified. CD44, a marker of reperfusion injury, and myristic acid, a potential preconditioning agent, were incorporated into a nanotheranostic that may be useful for cardiovascular applications. Integrating biomarker discovery techniques into rationally designed nanoconstructs may lead to improvements in disease-specific diagnosis and treatment.

1 August 2013 in Cleveland Clinic Journal of Medicine
Verified
Journal Article
Open access
PDF file
PGPatrick Gladding
Patrick Gladding

24 June 2026 in medRxiv
Verified
Preprint
Open access
PDF file
AVAlexandr Vikhorev
Alexandr Vikhorev
MSMaksim Struchalin
Maksim Struchalin
XSXiaoyan Sun
Xiaoyan Sun
YWYalu Wen
Yalu Wen
HWHelen Wihongi
Helen Wihongi
PGPatrick Gladding
Patrick Gladding
Background: Cardiovascular disease (CVD) is the leading cause of mortality in New Zealand, with significant inequities affecting Māori and Pacific peoples. Familial hypercholesterolemia (FH) affects approximately 1 in 313 individuals globally, yet over 90% remain undiagnosed. Standard polygenic risk scores (PRS) derived from European cohorts may not be portable to diverse ancestries. We developed the Holo-Q Omniscan Waka Te Ira, a custom Illumina Global Screening Array (GSA) v3 enriched with FH mutations, CAD PRS markers, and network medicine-derived epistasis content. Methods: Holo-Q Omniscan Waka Te Ira was developed as a customized version of the Illumina Global Screening Array v3, adding 43,437 SNPs targeting familial hypercholesterolaemia and coronary artery disease. Variants in the three primary FH genes were collected from a regional diagnostic laboratory list, published literature, ClinVar, and the Leiden Open Variation Database, resulting in 6,717 unique SNPs. Additional content included 14,005 pathogenic or likely pathogenic variants from cardiovascular, lipid-related genes and 12 pharmacogenes; and 5,845 probes supporting copy number variant detection. The array further incorporated 5,232 network medicine–derived coronary artery disease SNPs and 14,806 rare variants from a validated multi-ancestry polygenic score. To improve ancestral representation, 289 variants specific to New Zealand, European, Asian, and African populations, along with 118 variants specific to populations from Japan, Korea, Thailand, and Russia were added. Validation was performed using large-scale genotype and whole-genome sequencing datasets with polygenic score benchmarking. The completed design contained 47,027 SNPs overall, including 3,590 loci inherited from the GSA v3 backbone and 43,437 newly incorporated through custom content expansion. Results: Approximately half of the newly added SNPs were observed in a large European-ancestry dataset, with high recovery for common polygenic score loci but low recovery for population-specific founder variants. The array captured 938 (84%) of all unique pathogenic or likely pathogenic familial hypercholesterolaemia variants catalogued in ClinVar at the time of design, representing a 26.4% expansion beyond the standard backbone array. Whole-genome sequencing validation identified additional carriers of rare high-impact variants present only in the custom content. The selected coronary artery disease polygenic score model achieved an adjusted area under the receiver operating characteristic curve of 0.786. Together, these results demonstrate enhanced monogenic detection, robust polygenic performance, and improved representation of ancestrally diverse populations within a single screening platform. Conclusion: The Holo-Q Omniscan Waka Te Ira enhances detection of clinically relevant FH variants and provides robust PRS coverage. The low recovery of population-specific alleles in UK datasets underscores the necessity of this custom array for equitable genomic medicine in New Zealand’s multi-ethnic population.

28 February 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
YLYusmiati Liau
Yusmiati Liau
SCSimone L. Cree
Simone L. Cree
Simran DS MaggoSimran DS Maggo
Simran DS Maggo
AMAllison L. Miller
Allison L. Miller
JPJohn Pearson
John Pearson
MKMartin Alexander Kennedy
Martin Alexander Kennedy
Aim: The MinION nanopore sequencing device opens the opportunity to cost-effective and point-of-care DNA sequencing. We developed a multiplex assay targeting pharmacogenetic variants related to clopidogrel and warfarin, two commonly used drugs that show response variability due to genetic polymorphisms. Materials & Methods: Six reference and 78 clinical DNA samples were amplified by PCR to generate 15 amplicons targeting key variants. These products were then barcoded to enable sample multiplexing. Three variant calling tools were used to compare genotyping accuracy. Results and Conclusions: All but three samples were successfully sequenced and genotyped. Nanopolish software achieved accuracy > 90 % for all except one variant. While minor mis-genotyping issues exist, this work demonstrates that drug-specific or broad pharmacogenetic screening assays are possible on the MinION sequencing device.