8 December 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
HBHeba Beder
Heba Beder
BMBaraa Mohandes
Baraa Mohandes
MMMohamed Shawky El Moursi
Mohamed Shawky El Moursi
EBEbrahim A. Badran
Ebrahim A. Badran
MSMagdi M. El Saadawi
Magdi M. El Saadawi
Protection coordination for the microgrid system in both islanded and grid connected modes is considered a challenge for microgrid operation. The variation in short circuit currents in each mode of operation, limitation of protection curves in the relays, and the need for fast and reliable communication are the main challenges tackled in research. Direction overcurrent relays are considered the main protection instrument for the microgrid. However, one protection setting for both (main and backup) operation does not provide a fast-operating time. On the contrary, the dependence on communication to maintain the proper backup protection operation is not a reliable solution for protection system. Therefore, this paper introduces a fast, reliable, and simple protection scheme for secure microgrid operation in both islanded and grid connected modes. In this context, one set of protection settings is optimized and used in both modes of operation. A protection setting consists of two time-dial settings and one pickup current setting for each relay. The proposed design technique minimizes the total operating time for both main and backup relays. As all protection functions are executed in the forward direction, no communication is needed among relays. The proposed scheme is tested and verified on a modified portion of IEEE 30 bus test system equipped with distributed generation units. A comparative analysis is carried out and the results demonstrate superior performance by the proposed scheme in comparison with the dual setting scheme with communication.

3 December 2015 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
MRMohammad E. M. Rizk
Mohammad E. M. Rizk
FMFarhan Mahmood
Farhan Mahmood
Matti LehtonenMatti Lehtonen
Matti Lehtonen
EBEbrahim A. Badran
Ebrahim A. Badran
MAMansour H. Abdel-Rahman
Mansour H. Abdel-Rahman
Due to the current spreading of wind farms all over the world and their vulnerability to lightning strikes, it is important to investigate the lightning electromagnetic transients in wind farms. Underground cables are one of the essential parts in wind farms that link the turbines with the electrical grid. This paper investigates how the ground conductivity and relative permittivity, struck wind tower position, and rise time of lightning current influence the lightning electromagnetic fields impinging the underground cable sheath. The three-dimensional finite-difference time-domain method is implemented for this study. The lightning current through the cable sheath and its associated electric field can be effectively mitigated by connecting the grounding systems of the wind towers by underground bare wires called as counterpoise. Accordingly, the mitigation effect of counterpoise on the lightning current through the sheath and its associated electric field is also investigated. The results show that the lightning current through the cable sheath and its associated electric field is higher with lower ground conductivity. Moreover, it is revealed that the effect of both ground permittivity and struck wind tower position on the associated electric field and the sheath current is dependent on the ground conductivity.

23 September 2024 in IEEE Access
Verified
Journal Article
Open access
MIMohammed H. Ibrahim
Mohammed H. Ibrahim
EBEbrahim A. Badran
Ebrahim A. Badran
MAMansour H. Abdel-Rahman
Mansour H. Abdel-Rahman
The DC microgrids possess numerous pros, including enhanced reliability, increased efficiency, and a less complicated control system. Further, they provide a simplified system that facilitates the incorporation of renewable energy sources (RES), battery storage systems, and DC loads. DC microgrids improve resource coordination and utilization, thus offering a potential alternative to modern energy systems. DC power systems have unique features that make protecting DC microgrids from different types of faults very hard. These include large DC capacitors, low-impedance DC cables, no natural zero-crossing points, and significant transient current and voltage changes that happen very quickly. Also, solid-to-ground faults could result in a rapid increase in DC fault current. Therefore, a cost-effective and reliable system protection mechanism capable of detecting, locating, and isolating faults is crucial to preventing DC microgrids from experiencing power outages and failures. This paper presents a machine-learning-based protection approach for DC microgrids. The proposed methodology relies solely on measuring the current passing through the positive terminal at bus_1 in the modified IEEE 14-bus configuration. During the measurement, the DC microgrid encountered several fault scenarios. The gathered data is analyzed to train a supervised machine-learning method that uses medium-gaussian support vector machines and bagged tree classification algorithms. The effectiveness of this method was evaluated by conducting tests on a particular subset of the collected data using the trained model. The proposed protection technique was verified using MATLAB/Simulink software under several pole-pole (P-P) and pole-ground (P-G) fault conditions. The simulation results demonstrate that the proposed protection approach is practical and reliable across all fault scenarios. It is highly accurate at identifying and detecting precise fault locations without any errors.

24 July 2025 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
IHIbrahim Hamdeen
Ibrahim Hamdeen
EBEbrahim A. Badran
Ebrahim A. Badran
MKMohamed F. Kotb
Mohamed F. Kotb
MEMohamed Elgamal
Mohamed Elgamal

30 October 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
EAEman A. Awad
Eman A. Awad
EBEbrahim A. Badran
Ebrahim A. Badran
FYFathi H. Youssef
Fathi H. Youssef
This study investigates three different techniques to mitigate the switching overvoltages (SOVs) in the microgrids. At first, the effectiveness of reactive power compensation devices, such as static var compensator (SVC), is evaluated. After that, the performance of the supercapacitor (SC), as an energy storage device, is studied. Finally, with the addition of the SVC to the SC, the possibility to mitigate SOV by compensating both active and reactive power simultaneously is investigated. SOVs result due to unsymmetrical switching operation during de‐energisation (disconnection) procedures. The μG two operational modes; grid connected mode and isolated mode, are considered. A small hydro generation unit and three variable speed, double‐fed induction generator‐based wind turbines are the main renewable power generation units in the tested microgrid system. Alternative Transient Program is used in this study for simulating the compensation device, the energy storage device and the investigated microgrid. The study shows that through the μG two operational modes, the SC has priority over the other two investigated mitigation methods. Furthermore, using the SC or SC with SVC, the results have more regular voltage waveforms.

11 November 2022 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
MEMohamed M. El-Shafhy
Mohamed M. El-Shafhy
AAAlaa M. Abdel-hamed
Alaa M. Abdel-hamed
EBEbrahim A. Badran
Ebrahim A. Badran
Recently, there are increasing interest in studying the ferroresonance phenomenon, due to the various problems it causes to power quality and the destruction of network parts, insulators and consumer devices. As the ferroresonance leads to a significant increase in voltage or/and current with harmonic presence, both of which represent a threat to the stability of the electrical network and its parts. The influence of ferroresonance on the distribution system is crucial because the distribution system is the network's closest part to the consumer, and any effect it has will have an impact on the customer. This paper presents a state of the art of ferroresonance problem. The most visible signals for ferroresonance and analytical methods used to indicate its occurrence are presented. The investigation of ferroresonance in the radial distribution system and the effect of integrating Distributed Generation (DG) into the distribution zone on this phenomenon are presented. The latest methods used to mitigate and prevent ferroresonance are discussed. Furthermore a technique for suppressing ferroresonance is implemented. The ferroresonance in power transformer and the effect of load variation on it will be presented. PSCAD/EMTDC software is used to simulate the study.