In modern power systems, condition based monitoring and diagnosis is essential to ensure the effective and reliable operation of different high voltage equipment (HVE). Compared to other monitoring techniques, partial discharges (PD) measurement is considered as a key method for assessing the insulation health condition. The benefits of PD condition monitoring of HVE can be extended by proper detection, identification, and interpretation of PD signal. Among both on-line and off-line PD monitoring techniques, on-line PD monitoring is a very promising technique that assists in robust monitoring system which reduces the power failure incidents in power system components. Therefore, to understand recent developments and trends in theory and in practice, it is necessary to establish a holistic analysis of current on-line PD monitoring techniques for HVE in power systems. This paper presents an intensive literature review of current on-line PD monitoring techniques used for different high voltage electric components in power system. Finally, a smart PD monitoring techniques based on wireless sensor board is proposed. The proposed smart PD monitoring framework may be used to correctly estimate the insulation degradation in HVE and enhance the overall performance of power systems.
Partial discharges (PD) are produced in the stator insulation of electrical machines while energized. The sources of PD are internal voids, crack, and manufacturing defects, which keep on extending with its normal operation, leading to the complete failure of insulation. The intensity of PD is considerably influenced by the environmental factors, including surrounding temperature, pressure, humidity, and contamination. This paper investigates the influence of these factors on the PD activity in electrical machines and estimates the lifetime of insulation. The PD measurements were conducted by placing the motors in a climate-controlled chamber. The PD trend under varying environmental stresses was investigated over time. Accordingly, PD inception voltage and various discharge characteristic parameters such as accumulated apparent charge, cumulative energy function, average discharge current, discharge power, and quadratic rate have been determined. The combined effect of various environmental stresses on the PD activity was also investigated. The mathematical relationships were developed to estimate the discharge characteristics as the functions of pressure and temperature using the Gaussian model and the Exponential model. Finally, the endurance of insulation was estimated under different environmental conditions based on the average discharge current to differentiate between correct and incorrect PD measurements and to develop a right maintenance schedule for motors in service.
3 December 2015 in IEEE Transactions on Electromagnetic Compatibility
Due to the current spreading of wind farms all over the world and their vulnerability to lightning strikes, it is important to investigate the lightning electromagnetic transients in wind farms. Underground cables are one of the essential parts in wind farms that link the turbines with the electrical grid. This paper investigates how the ground conductivity and relative permittivity, struck wind tower position, and rise time of lightning current influence the lightning electromagnetic fields impinging the underground cable sheath. The three-dimensional finite-difference time-domain method is implemented for this study. The lightning current through the cable sheath and its associated electric field can be effectively mitigated by connecting the grounding systems of the wind towers by underground bare wires called as counterpoise. Accordingly, the mitigation effect of counterpoise on the lightning current through the sheath and its associated electric field is also investigated. The results show that the lightning current through the cable sheath and its associated electric field is higher with lower ground conductivity. Moreover, it is revealed that the effect of both ground permittivity and struck wind tower position on the associated electric field and the sheath current is dependent on the ground conductivity.
21 April 2016 in IEEE Transactions on Power Delivery
It is essential that the insulation system of the overhead distribution lines should be properly designed to ensure their immunity against lightning-induced overvoltages (LIOVs) caused by nearby return strokes. Therefore, accurate calculation of the peak values of LIOVs is important for the insulation design. In this paper, a formula is proposed to calculate the peak values of LIOVs for both first and subsequent strokes. The typical waveforms of the first and subsequent return strokes are adopted for this study considering a wide range of ground resistivity, from 0.25 to 20 kΩm. The 2-D finite-difference time-domain method associated with the Agrawal coupling model is employed for the calculation of LIOVs. In addition, the effect of ground permittivity on the peak values of LIOVs is also investigated. Finally, the proposed formula is applied to calculate the annual number of flashovers per 100 km of the overhead line.
31 July 2023 in IEEE Transactions on Industry Applications
Partial discharge (PD) diagnostics is regarded as one of the powerful methods for the detection of potential electrical insulation defects in a medium voltage (MV) and high voltage (HV) switchgear. This paper proposes a risk-based approach to identify the severity of several critical electrical defects in MV/ HV switchgear through PD testing. To accomplish this, several defects have been artificially created in a MV switchgear. The testing was carried out in the laboratory to investigate the characteristics of PD signals using D-dot sensor previously used and validated by the authors. Accordingly, the specific PD intensity of the discharge pulse has been considered as stress parameter and statistically modeled by an appropriate probability distribution. In this way, the probability of dielectric failure has been statistically quantified. The consequences of dielectric failure, and hence, the failure of the switchgear have been presented in terms of power outage cost and repair expenditures. The risk assessment is carried out by combing the probability of failure and its consequence. The estimated risk is an indication of the severity of the fault and can be specified as low, medium, high, or maximum. In this way, the proposed approach can be easily adopted by asset manager for risk assessment of switchgear in the petroleum and chemical industries.
28 March 2023 in IEEE Transactions on Aerospace and Electronic Systems
Typically, partial discharges (PD) diagnostic tests are carried out in laboratories under standard atmospheric conditions. However, during operation of electric motors (EM), environmental stresses may increase due to variations in the atmospheric pressure and temperature. This is, for example, the case of electrical aircrafts and, in general, aerospace. Experimental results show that these stresses may affect the level and phenomenology of PD, so as to harm insulation system reliability. Therefore, neglecting the actual environmental stresses involved in PD testing or monitoring may result in incorrect interpretation health condition of EM. This study presents a framework to properly assess the impact of environmental stresses on PD activity and estimate the failure risk of EM insulation. For this purpose, PD diagnostics were carried out by performing a number of experiments on seven EM in a climate-controlled chamber. PD characteristic features at different levels of environmental stresses are extracted from measurements in order to investigate the PD severity and infer their effect on the resulting insulation degradation. Also, various probability distribution functions are used to estimate the probability of failure and risk assessment corresponding to the PD severity at different levels of environmental stresses. The proposed risk assessment technique can be helpful to plan regular maintenance activities and repair-replacement actions, keeping the reliability at the level requested for most of the industrial applications involved with variable temperature and pressure operations.