雨蔓 宋

Dr. 雨蔓 宋


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2024 in Symmetry
Verified
Journal Article
Open access
PDF file
Yongji CaoYongji Cao
Yongji Cao
雨宋雨蔓 宋
雨蔓 宋
XLXiaoming Liu
Xiaoming Liu
CLChanggang Li
Changgang Li
The multivariate coupling and symmetry characteristic of a synchronous condenser and its excitation system (SCES) poses a challenge for parameter identification. This paper proposes a parameter identification approach for the SCES considering multivariate coupling and symmetry characteristics. The key parameters of the synchronous condenser under different time scales are selected. Then, the sensitivity analysis method is utilized to classify the parameters and establish the sets of coupling variables. In addition, the response mechanism and characteristics of the SCES under steady-state, sub-transient, and transient conditions are analyzed, based on which the parameter identification models are established separately. Moreover, the measurement data noise is processed by the wavelet threshold denoising method. According to the coupling variable sets, an improved snake optimization method based on Tent chaotic mapping is adopted for a solution. A case study is conducted to validate the effectiveness of the proposed approach. The results show that the proposed approach is able to improve the identification precisely and reduce the mode response error.

18 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
RLRuqi LIU
Ruqi LIU
YZYifu Zhang
Yifu Zhang
GSGao Song
Gao Song
DLDexin Li
Dexin Li
CLCheng LIU
Cheng LIU
雨宋雨蔓 宋
雨蔓 宋
The integration of grid-forming wind turbines introduces forced oscillations and harmonic/inter-harmonic interference, which degrades the accuracy of traditional energy-flow-based source localization methods. To address this issue, this paper proposes a novel method based on improved complete ensemble empirical mode decomposition with Adaptive Noise (ICEEMDAN) and an improved Teager energy operator (ITEO). The proposed method first employs ICEEMDAN to adaptively decompose wide-area measurement signals, effectively suppressing mode mixing and noise. Then, ITEO is utilized to extract the dominant oscillation components. By incorporating an adjustable computation window, ITEO enhances frequency selectivity, amplifying force oscillations while suppressing high-frequency noise, leading to robust energy estimation. Following this, the dissipative modal energy flow is calculated from the reconstructed time-domain waveforms. Ultimately, the disturbance source is precisely identified based on the dissipative energy flow theory. The method is validated through extensive simulations on a multi-bus test system with grid-forming wind turbines, considering disturbances from both synchronous generator excitations and wind turbine internal controls, as well as in high-noise environments. Additional validation using a real-world oscillation event from the ISO New England system confirms that the proposed method achieves superior accuracy and robustness compared to conventional methods.

11 September 2026 in Symmetry
Verified
Journal Article
Open access
PDF file
MLMu Li
Mu Li
SWShouyuan Wu
Shouyuan Wu
雨宋雨蔓 宋
雨蔓 宋
The growing penetration of renewable energy sources introduces significant uncertainties into integrated energy systems (IESs). Conventional single-timescale management strategies, typically designed for static power balance, fail to address the symmetry of source-load uncertainties arising from both supply and demand sides. To address this challenge, this paper proposes a multi-timescale optimal scheduling framework that integrates demand response (DR) and multi-energy flow coupling. The framework adopts a hierarchical progressive strategy across day-ahead, intra-day, and real-time stages. The day-ahead stage optimizes the economic baseline with an hourly resolution. The intra-day stage conducts rolling correction at 15 min intervals to activate slow-response equipment flexibility, boosting combined heat and power (CHP) generation by 40.70% and increasing waste-heat cooling consumption by 41.12%. The real-time stage employs energy storage at 5 min resolution to suppress fluctuations, maintaining electricity, heat, and cooling load deviations, respectively, at remarkably low levels of 0.17%, 0.10%, and 0.06%. Comparative results show that with power-to-gas (P2G) integration, the system purchases off-peak electricity for synthetic natural gas production, cutting gas procurement costs by 12.70% and reducing net carbon emissions from 5.14 t to 4.91 t. DR mechanisms enable a gas–electricity substitution strategy that lowers electricity purchase costs by 9.97%, reduces evening peak electric vehicle (EV) charging load by 8.32%, and decreases charging expenses by 15%.