Renewable energy’s growing penetration erodes traditional power systems’ inherent dynamic symmetry—balanced inertia, damping, and frequency response. This paper proposes a self-adaptive virtual synchronous generator (VSG) control strategy for a photovoltaic hybrid energy storage system (PV-HESS) based on a radial basis function (RBF) neural network. The strategy establishes a dynamic adjustment framework for inertia and damping parameters via online learning, demonstrating enhanced system stability and robustness compared to conventional VSG methods. In the structural design, the DC-side energy storage system integrates a passive filter to decouple high- and low-frequency power components, with the supercapacitor attenuating high-frequency power fluctuations and the battery stabilizing low-frequency power variations. A small-signal model of the VSG active power loop is developed, through which the parameter ranges for rotational inertia (J) and damping coefficient (D) are determined by comprehensively considering the active loop cutoff frequency, grid connection standards, stability margin, and frequency regulation time. Building on this analysis, an adaptive parameter control strategy based on an RBF neural network is proposed. Case studies show that under various conditions, the proposed RBF strategy significantly outperforms conventional methods, enhancing key performance metrics in stability and dynamic response by 16.98% to 70.37%.
The growing penetration of renewable energy sources introduces significant uncertainties into integrated energy systems (IESs). Conventional single-timescale management strategies, typically designed for static power balance, fail to address the symmetry of source-load uncertainties arising from both supply and demand sides. To address this challenge, this paper proposes a multi-timescale optimal scheduling framework that integrates demand response (DR) and multi-energy flow coupling. The framework adopts a hierarchical progressive strategy across day-ahead, intra-day, and real-time stages. The day-ahead stage optimizes the economic baseline with an hourly resolution. The intra-day stage conducts rolling correction at 15 min intervals to activate slow-response equipment flexibility, boosting combined heat and power (CHP) generation by 40.70% and increasing waste-heat cooling consumption by 41.12%. The real-time stage employs energy storage at 5 min resolution to suppress fluctuations, maintaining electricity, heat, and cooling load deviations, respectively, at remarkably low levels of 0.17%, 0.10%, and 0.06%. Comparative results show that with power-to-gas (P2G) integration, the system purchases off-peak electricity for synthetic natural gas production, cutting gas procurement costs by 12.70% and reducing net carbon emissions from 5.14 t to 4.91 t. DR mechanisms enable a gas–electricity substitution strategy that lowers electricity purchase costs by 9.97%, reduces evening peak electric vehicle (EV) charging load by 8.32%, and decreases charging expenses by 15%.