Hand synergies have been extensively studied over the last few decades. Objectives of such research are numerous. In neuroscience, the aim is to improve the understanding of motor control and its ability to reduce the control dimensionality. In applied research fields like robotics the aim is to build biomimetic hand structures, or in prosthetics to design more performant underactuated replacement hands. Nevertheless, most of the synergy schemes identified to this day have been obtained from grasping experiments performed with one single (generally dominant) hand to objects placed in a given position and orientation in space. Aiming at identifying more generic synergies, we conducted similar experiments on postural synergy identification during bimanual manipulation of various objects in order to avoid the factors due to the extrinsic spatial position of the objects.
26 June 2009 in IEEE Transactions on Biomedical Engineering
Off-pump totally endoscopic coronary artery bypass grafting is a milestone for cardiac surgery, and still a technical challenge. Indeed, the fast and complex cardiac motion makes this operating method technically demanding. Therefore, several robotic systems have been designed to assist the surgeons by compensating for the cardiac motion and providing a virtually motionless operating area. In the proposed systems, the servoing schemes often take advantage of a prediction algorithm that supplies the controller with some future heart motion. This prediction enlarges the control-loop bandwidth, thus allowing a better motion compensation. Obviously, improving the prediction accuracy will lead to better motion-compensation results. Thus, a current challenge in computer-assisted cardiac surgery research is the design of efficient heart-motion-prediction algorithms. In this paper, a detailed survey of the main existing prediction approaches is given and a classification is provided. Then, a novel prediction technique based on amplitude modulation is proposed, and compared with other techniques using in vivo collected datasets. A final discussion summarizes the main features of all the proposed approaches.
In this paper, control strategies for an active stabilizer dedicated to beating heart coronary artery bypass grafting are investigated. The active stabilizer, which consists of a piezoactuated compliant mechanism, has to be controlled to compensate for the displacements induced by the beating heart in order to provide the surgeon with a locally motionless myocardium surface. Three controllers, including different levels of prior knowledge about the heart motion, are presented. Their performance with respect to modeling uncertainties, arising unknown interactions of the stabilizer with its positioning mechanism, and the heart, is studied through simulations, as well as laboratory and in vivo experiments. Finally, the selection of the most adequate control scheme and the performance of the device from a clinical point of view are discussed.
18 May 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Attendant joysticks of powered wheelchairs are devices oriented to help caregivers. Diseases and disabilities such as dementia, spinal cord injuries or blindness make the user unable to drive the chair by his or her own. However, this device is not intuitive to use, especially for old people. Proper processing of the information provided by two tactile sensors in the handlebar achieves control signals that allow an easy and intuitive driving. This is done in this paper, where the performance of this approach is evaluated in comparison with that of the joystick by means of objective measurements as well as questionnaires to obtain the subjective perception of the participants in the experiments. The results show a better performance of the handlebar in terms of error in following a trajectory, collisions with the surrounding furniture, and user feeling related to ease of use, comfort, required training, usefulness, safety and fatigue.
Off-pump Coronary Artery Bypass Grafting (CABG) is still a technically difficult procedure. The mechanical stabilizers used for local suppression of the heart excursion have been demonstrated to exhibit significant residual motion, which could lead to a lack of accuracy in performing the surgical task, particularly when using a minimally invasive surgery (MIS) approach. We therefore propose a novel active stabilizer to compensate for the residual motion whose architecture is compatible with MIS. An experimental evaluation of a commercially available totally endoscopic stabilizer is first presented to demonstrate the unsatisfactory behavior of this device. Then, the interaction between the heart and a mechanical stabilizer is assessed in vivo using an animal model. Finally, the principle of active stabilization, based on the high-speed vision-based control of a piezo-actuated compliant mechanism, is presented, along with in vivo experimental results obtained using a prototype to demonstrate its efficiency.
Postural control rehabilitation may benefit from the use of smart devices providing biofeedback. This approach consists of increasing the patients perception of their postural state. Namely, postural state is monitored and fed back in real time to the patients through one or more sensory channels. This allows implementing rehabilitation exercises where the patients control their posture with the help of additional sensory inputs. In this paper, a closed loop control of the Center-Of-Pressure (CoP) based on kinesthetic feedback is proposed as a new form of biofeedback. The motion of a one Degree of Freedom (DoF) translational device, lightly touched by the patient's forefinger, is servoed to the patient's CoP position extracted from the measurements of a force plate on which he/she stands. As a result, the patient's CoP can be controllably displaced. A first set of experiments is used to prove the feasibility of this closed-loop control under ideal conditions favoring the perception of the kinesthetic feedback, while the subject is totally unaware of the context. A second set of experiments is then proposed to evaluate the robustness of this approach under experimental conditions that are more realistic with regards to the clinical context of a rehabilitation program involving biofeedback-based exercises.