Saidabdullo Qurbonalizoda

Saidabdullo Qurbonalizoda

Auto-generated profile, based on publicly available information

Saidabdullo Qurbonalizoda


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2025 in Processes
Verified
Journal Article
Open access
PDF file
BFBohua Feng
Bohua Feng
CYChen Yang
Chen Yang
QZQianying Zhou
Qianying Zhou
XGXiaomei Guo
Xiaomei Guo
QSQurbonalizoda Saidabdullo Shamsullo
Qurbonalizoda Saidabdullo Shamsullo
XXXuefeng Xu
Xuefeng Xu
The cutting process is accompanied by complex electrical phenomena, which are particularly evident in narrow cutting clearances. To further explore the laws of electrical phenomena in the capillary of the cutting zone, this paper uses a Faraday collector with an external bias electric field to investigate the electrical phenomena in the narrow slit of the cutting zone under different cutting parameters and when different tool and workpiece materials are combined. The results show that there is a stable and continuous electrical phenomenon in the cutting contact area, and the emission intensity of charged particles when cutting insulating materials is significantly higher than that of metals. The emission intensity of negative ions is higher than that of positive ions. The electrical and mechanical properties of materials have a significant impact on the electrical phenomena in the cutting zone. In addition, it was found that there is a linear relationship between the electrical phenomena in the cutting zone and the cutting parameters. Finally, based on the morphology of the capillaries in the cutting zone, the self-excited electric field intensity generated in it during the cutting process was estimated.

26 November 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
WWWuji Wangsun
Wuji Wangsun
XGXiaomei Guo
Xiaomei Guo
PLPING LI
PING LI
ZZZuchao Zhu
Zuchao Zhu
Aminjon Gulahmadzoda (Gulakhmadov)Aminjon Gulahmadzoda (Gulakhmadov)
Aminjon Gulahmadzoda (Gulakhmadov)
SQSaidabdullo Qurbonalizoda
Saidabdullo Qurbonalizoda
To investigate the influence of different tip clearances on the hydraulic performance and cavitation characteristics of a cryogenic inducer, this study builds upon previous research by employing the SST k-ω turbulence model and modifying the empirical coefficients for evaporation and condensation in the Zwart cavitation model. Numerical simulations of the full flow field within an LNG cryogenic inducer were conducted. The results yielded cavitation performance curves, pressure distributions at incipient cavitation, vapor volume fraction contours, and leakage flow streamlines for various tip clearances. The impact of tip clearance on the overall hydraulic performance and cavitation behavior of the LNG inducer was systematically examined, with particular attention given to the microscopic evolution of the Tip Leakage Vortex (TLV) during the initial stages of cavitation. Experimental findings indicate that as the tip clearance increases, the tip leakage flow intensifies, leading to greater energy losses within the inducer and a consequent slight reduction in pump head and efficiency. A critical clearance value, δ, exists within the range of 0.4 mm to 0.6 mm, which governs the development pattern of the TLV. When the clearance is smaller than δ, the TLV forms more rapidly, and cavitation development is significantly more sensitive to increases in tip clearance. Conversely, when the clearance exceeds δ, the formation of the TLV is delayed, and cavitation progression becomes less responsive to further increases in tip clearance.

14 January 2026 in Water
Verified
Journal Article
Open access
PDF file
SWSunwuji Wang
Sunwuji Wang
XGXiaomei Guo
Xiaomei Guo
PLPING LI
PING LI
ZZZuchao Zhu
Zuchao Zhu
Aminjon Gulahmadzoda (Gulakhmadov)Aminjon Gulahmadzoda (Gulakhmadov)
Aminjon Gulahmadzoda (Gulakhmadov)
SQSaidabdullo Qurbonalizoda
Saidabdullo Qurbonalizoda
Inducers play a critical role in pump operation by providing a preliminary pressure boost to suppress cavitation. The size of the tip clearance directly influences a pump’s operational efficiency. To investigate the impact of tip clearance on a pump’s hydraulic performance and its behavior under cavitation conditions, this study combines experimental and numerical simulation approaches. Numerical computations of the full flow field, including the inducer and a two-stage impeller, were performed for five liquefied natural gas (LNG) cryogenic inducers with different tip clearances. The accuracy of the numerical simulation results was validated by comparing them with the experimentally obtained hydraulic performance curves. The results yield cavitation performance curves, pressure distributions at incipient cavitation, vapor volume fraction contours, and leakage flow streamlines for various tip clearances. The impact of tip clearance on the overall hydraulic performance and cavitation behavior of the LNG inducer was systematically examined, with particular attention given to the microscopic evolution of the Tip Leakage Vortex (TLV) during the initial stages of cavitation. The experimental results indicate that for every 0.2 mm increase in the inducer tip clearance, the pump head decreases by approximately 1 m, the efficiency drops by about 0.2%, and the tip leakage flow rate increases by approximately 5 m3/h. Furthermore, under cavitation conditions, the cavitation area expands as the tip clearance increases. A critical clearance value, δ, exists within the range of 0.4 mm to 0.6 mm, which governs the development pattern of the TLV. When the clearance is smaller than δ, the TLV forms more rapidly, and cavitation development is significantly more sensitive to increases in tip clearance. Conversely, when the clearance exceeds δ, the formation of the TLV is delayed, and cavitation progression becomes less responsive to further increases in tip clearance.