With the increasing integration of renewable energy into power grids, integrated energy systems (IES) have gained global attention. However, the stochastic and uncertain characteristics of wind and solar challenge the stable grid operation significantly. To address these issues, this article proposes an optimal scheduling model for wind-solar-hydrogen IES, incorporating prediction uncertainty and demand response (DR). The equilibrium decision theory framework, combined with frequency enhanced decomposed transformer, interval prediction and decision, is proposed to quantify the uncertainties and determine the action plans. Then, an optimal scheduling model is designed to maximize economic revenue and minimize pollution emissions (PE), which is solved using multiobjective elephant clan optimization algorithm. Furthermore, DR strategy is integrated to enhance system flexibility and stability. Empirical results demonstrate that increased uncertainty leads to more conservative scheduling, improving system robustness. Additionally, DR boosts ER by over 3.50% and reduces PE by more than 3.20% across various scenarios.
Accurate load forecasting of central air conditioning (CAC) systems is crucial for enhancing energy efficiency and minimizing operational costs. However, the complex nonlinear correlations among meteorological factors, water system dynamics, and cooling demand make this task challenging. To address these issues, this study proposes a novel hybrid forecasting model termed IWOA-BiTCN-BiGRU-SA, which integrates the Improved Whale Optimization Algorithm (IWOA), Bidirectional Temporal Convolutional Networks (BiTCN), Bidirectional Gated Recurrent Units (BiGRU), and a Self-attention mechanism (SA). BiTCN is adopted to extract temporal dependencies and multi-scale features, BiGRU captures long-term bidirectional correlations, and the self-attention mechanism enhances feature weighting adaptively. Furthermore, IWOA is employed to optimize the hyperparameters of BiTCN and BiGRU, improving training stability and generalization. Experimental results based on real CAC operational data demonstrate that the proposed model outperforms traditional methods such as LSTM, GRU, and TCN, as well as hybrid deep learning benchmark models. Compared to all comparison models, the root mean square error (RMSE) decreased by 13.72% to 56.66%. This research highlights the application potential of the IWSO-BiTCN-BiGRU-Attention framework in practical load forecasting and intelligent energy management for large-scale CAC systems.