The energy efficiency of data centers has become an urgent problem as it is enjoying rapid development. This study proposes an integrated energy system involving a data center with different renewable energy sources and waste heat recovery, which can consider the partial and unsteady working load of data center. A dynamic and sophisticated system simulation model is established, which can provide both reliable and fast evaluations but also allow flexible extension of additional components. It is found that the free natural resource cooling system can cover about 28% of cooling demand. Compared to the reference condition, the proposed energy system achieves significant energy-saving benefits, with an energy-saving rate of 16.4%. The system COP increases from 3.88 to 4.64, and the PUE decreases from 1.36 to 1.30, resulting in a 23.45% reduction in electricity expenses. By integrating a waste heat recovery system, the heat pump can absorb approximately 3.57 million kWh of heat from the data center, providing approximately 4.587 million kWh of heating energy for users. The rooftop PV system generates approximately 370,000 kWh of electricity annually, covering approximately 8% of the total electricity consumption of the data center. This study can offer a new channel for the energy efficiency enhancement of data centers.

23 July 2025 in Buildings
Verified
Journal Article
Open access
PDF file
YZYu Zhang
Yu Zhang
WHWei He
Wei He
JHJinyan Hu
Jinyan Hu
CZChaohui Zhou
Chaohui Zhou
BRBo Ren
Bo Ren
WLWeili Liu
Weili Liu
Accurate assessment of urban rooftop solar photovoltaic (PV) potential is critical for the low-carbon energy transition. This study presents a deep learning-based approach using high-resolution (0.5 m) aerial imagery to automatically identify building rooftops in the central urban area of Wuhan, China (covering seven districts), and to estimate their PV installation potential. Two state-of-the-art semantic segmentation models (DeepLabv3+ and U-Net) were trained and evaluated on a local rooftop dataset; U-Net with a ResNet50 backbone achieved the best performance with an overall segmentation accuracy of ~94%. Using this optimized model, we extracted approximately 130 km2 of suitable rooftop area, which could support an estimated 18.18 GW of PV capacity. These results demonstrate the effectiveness of deep learning for city-scale rooftop mapping and provide a data-driven basis for strategic planning of distributed PV installations to support carbon neutrality goals. The proposed framework can be generalized to facilitate large-scale solar energy assessments in other cities.

10 November 2025 in Buildings
Verified
Journal Article
Open access
PDF file
YLYuce Liu
Yuce Liu
CZChaohui Zhou
Chaohui Zhou
YHYue Hu
Yue Hu
WZWenkai Zhang
Wenkai Zhang
WHWei He
Wei He
WGWeiwei Guan
Weiwei Guan
The increasing energy consumption of large datacenters, with cooling systems constituting a significant portion, calls for efficient thermal management strategies. Conventional computational fluid dynamics (CFD) methods, although accurate, are time-consuming for supporting real-time tasks in dynamic datacenter environments. Machine learning (ML)-based methods, particularly artificial neural network (ANN)-based surrogate models, have emerged as potential alternatives, but they struggle with generalization across diverse working conditions. Meanwhile, ML models’ performance in large datacenters still remains unclear. This research introduces a hybrid surrogate model combining ANNs and CNNs for the precise and rapid prediction of 3D temperature distributions in large datacenters. The proposed method incorporates an ANN for feature processing and a CNN for decoding spatial features, leveraging both to capture complex airflow patterns and temperature distributions under varying conditions. A dataset of 500 CFD-simulated temperature fields based on a real datacenter is established for model training and validation. The CFD method is evaluated by comparing the simulation results with experimental data. Results of the ML models’ performance indicate that the proposed hybrid surrogate model outperforms the conventional ANN model, reducing mean absolute error (MAE) by 87.44%. Additionally, the model is 300,000 times faster than CFD simulations, offering an efficient solution for further supporting real-time thermal management.

31 October 2025 in Energies
Verified
Journal Article
Open access
PDF file
WHWei He
Wei He
RHRui Hua
Rui Hua
YXYulong Xiao
Yulong Xiao
YLYuce Liu
Yuce Liu
CZChaohui Zhou
Chaohui Zhou
Chaoshun LiChaoshun Li
Chaoshun Li
Accurate load forecasting of central air conditioning (CAC) systems is crucial for enhancing energy efficiency and minimizing operational costs. However, the complex nonlinear correlations among meteorological factors, water system dynamics, and cooling demand make this task challenging. To address these issues, this study proposes a novel hybrid forecasting model termed IWOA-BiTCN-BiGRU-SA, which integrates the Improved Whale Optimization Algorithm (IWOA), Bidirectional Temporal Convolutional Networks (BiTCN), Bidirectional Gated Recurrent Units (BiGRU), and a Self-attention mechanism (SA). BiTCN is adopted to extract temporal dependencies and multi-scale features, BiGRU captures long-term bidirectional correlations, and the self-attention mechanism enhances feature weighting adaptively. Furthermore, IWOA is employed to optimize the hyperparameters of BiTCN and BiGRU, improving training stability and generalization. Experimental results based on real CAC operational data demonstrate that the proposed model outperforms traditional methods such as LSTM, GRU, and TCN, as well as hybrid deep learning benchmark models. Compared to all comparison models, the root mean square error (RMSE) decreased by 13.72% to 56.66%. This research highlights the application potential of the IWSO-BiTCN-BiGRU-Attention framework in practical load forecasting and intelligent energy management for large-scale CAC systems.

25 August 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
CZChaohui Zhou
Chaohui Zhou
RLRujie Liu
Rujie Liu
HCHaoran Cheng
Haoran Cheng
Yongqiang LuoYongqiang Luo
Yongqiang Luo
Ground source heat pump (GSHP) systems contribute to sustainable building decarbonization while confronting two intertwined challenges: long-term ground thermal imbalance in shallow borefields and the requirement for coordinated operation between thermal systems and electrical grid dynamics. Hybrid shallow–deep borefield configurations have been proposed to mitigate thermal imbalance for sustainable geothermal resource exploitation, yet their grid-interactive demand–response potential remains unexplored. Here, we develop a coupled thermal–electrical model for a shallow–deep mixed GSHP (SDBHE) system equipped with water-tank thermal storage, validated against scaled sand-tank experiments (3.5–8.3% error), and assess its year-round performance under time-of-use electricity tariffs for a 200,000 m2 residential district in cold-climate conditions. The SDBHE system reduces the required shallow borehole count by 28% and total drilling length by 22% compared with a shallow-only baseline, saving 11% on operational electricity costs over 10 years. Integrating water-tank thermal storage with a 50% load-shifting strategy yields an additional 10.9–11% cost reduction without degrading the system’s coefficient of performance. Under higher load-shifting ratios, the combined capital and operational savings reach 19–29%, with the optimal allocation assigning the incremental high-price-period load preferentially to deep boreholes (COP 6.29 versus 5.25 for shallow). These results demonstrate that integrating shallow and deep geothermal tiers with thermal storage enables both capital-efficient borefield design and economically viable demand-side grid participation. The findings are bound by the cold-climate residential context and the rule-based control scheme; field-scale validation and lifecycle cost analysis are needed to generalize the conclusions.