Aleksander Sokolov

Dr. Aleksander Sokolov


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2005 in X-Ray Spectrometry
Verified
Journal Article
Closed access
PDF file
ASAleksander Sokolov
Aleksander Sokolov
DDD. Docenko
D. Docenko
EBE. Bliakher
E. Bliakher
OSO. Shirokobrod
O. Shirokobrod
JKJuha Koskinen
Juha Koskinen

11 November 2025 in Mining
Verified
Journal Article
Open access
PDF file
ASAleksander Sokolov
Aleksander Sokolov
VKVitalijs Kuzmovs
Vitalijs Kuzmovs
UOUlises Miranda Ordonez
Ulises Miranda Ordonez
VGVladimir Gostilo
Vladimir Gostilo
The determination of the elemental composition of minerals at mining enterprises is important at all stages of mineral processing. An evaluation of metrological characteristics achieved through the online analysis of lump, ore, charge feed, cake and slag materials on a conveyor belt is presented. Each implementation of the online XRF analysis at mining enterprises was preceded by laboratory studies, the development of measurement methods and the calibration of a specific XRF analyzer using standard reference samples for a specific concentration range of the monitored elements. In this work, typical application areas for monitoring the concentration of elements in rocks on conveyor belts are presented, as well as those solutions that made it possible to achieve the required measurement accuracy with an X-ray fluorescence analyzer in an online mode.

4 July 2019 in Coatings
Verified
Journal Article
Open access
PDF file
ASAleksander Sokolov
Aleksander Sokolov
JHJelena Hasikova
Jelena Hasikova
APAleksejs Pecerskis
Aleksejs Pecerskis
VGVladimir Gostilo
Vladimir Gostilo
Aluminium coatings that are formed by physical vapour deposition (PVD) on rolled steel products are more resistant to atmospheric and seawater corrosion than zinc coatings. We developed a coating thickness analyzer (CTA) with an X-ray fluorescence (XRF) measuring head, that is integrated into the PVD pilot line. In this study, to conduct measurements of elements with atomic numbers less than 20 while avoiding the problem of registration of light elements, the measuring head was integrated into a process vacuum chamber to maintain a vacuum during the measurements. To validate the proposed tool, cold-rolled steel strips of different grades are used as substrates, and aluminium was deposited on the surface via PVD in thicknesses ranging from 1 to 20 g/m2. The thin-film thickness measurements during a pre-acceptance test were found to have a relative accuracy of less than 5% and a relative precision of less than 1–2%. The proposed CTA can be readily integrated in the factory’s automatic process control system and the real-time measurements in operating and calibration modes, and the status of all spectrometric equipment (X-ray tube, detector etc.) can be transmitted to the upper-level computer. Thus, the process engineer can properly control the deposition process.

30 March 2018 in Coatings
Verified
Journal Article
Open access
PDF file
ASAleksander Sokolov
Aleksander Sokolov
JHJelena Hasikova
Jelena Hasikova
APAleksej Pecerskis
Aleksej Pecerskis
VGVladimir Gostilo
Vladimir Gostilo
KLKi Yong Lee
Ki Yong Lee
JLJung Hyun Lim
Jung Hyun Lim
The results of industrial application of an online X-ray fluorescence coating thickness analyzer for measuring the thickness of phosphate coatings on moving steel strips are considered in the article. The target range of coating thickness to be measured is from tens to hundreds of mg/m2 in a measurement time of 10 s. The measurement accuracy observed during long-duration factory acceptance test was 10–15%. The coating thickness analyzer consists of two XRF gauges, mounted above and below the steel strip and capable of moving across the moving strip system for their suspension and relocation and electronic control unit. Fully automated software was developed to automatically and continuously (24/7) control both gauges, scanning both sides of the steel strip, and develop and test methods for measuring new coatings. It allows performing offline storage and retrieval of the measurement results, remotely controlling the analyzer components and measurement modes from a control room. The developed XRF coating thickness analyzer can also be used for real-time measurement of other types of coatings, both metallic and non-metallic.

1 January 2019 in Journal of the Southern African Institute of Mining and Metallurgy
Verified
Journal Article
Open access
PDF file
ASAleksander Sokolov
Aleksander Sokolov
VGV. Gostilo
V. Gostilo
MDM. Demsky
M. Demsky
EHE. Hasikova
E. Hasikova

7 October 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
ASAleksander Sokolov
Aleksander Sokolov
VKVitalijs Kuzmovs
Vitalijs Kuzmovs
UOUlises Miranda Ordonez
Ulises Miranda Ordonez
VGVladimir Gostilo
Vladimir Gostilo
Determination of the elemental composition of minerals and their derivatives at mining enterprises is important at all stages of minerals processing. This paper is devoted to the results of development and application of an online X-ray fluorescence (XRF) analysis method for monitoring mineral elements on a conveyor belt of mining enterprises. Evaluation of metrological characteristics achieved in the online analysis of lump, ore, charge feed, cake and slag materials on conveyor belt is presented. Each implementation of the online XRF analysis at mining enterprises was preceded by laboratory studies, development of measurement methods, calibration of a specific XRF analyzer using standard reference samples for a specific concentration range of the monitored elements. Typical areas of application for monitoring the concentration of elements in rocks on conveyor belts of mining enterprises and those solutions that made it possible to achieve the required measurement accuracy of an X-ray fluorescence analyzer in online mode are presented.