Sara Leonini

Dr. Sara Leonini


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
Irene GrazziniIrene Grazzini
Irene Grazzini
DRDavide Del Roscio
Davide Del Roscio
MCMarco Cirinei
Marco Cirinei
BCBenedetta Calchetti
Benedetta Calchetti
MGMatteo Grammatico
Matteo Grammatico
LTLorenzo TESTAVERDE
Lorenzo TESTAVERDE
Background/Objectives: The aim of the study was to compare diagnostic performance of 3D-Double Inversion Recovery (DIR) and 3D-Fluid-Attenuated Inversion Recovery (FLAIR) sequences in the detection of brain lesions in Multiple Sclerosis (MS) patients, especially cortical ones, and to evaluate potential correlation between lesion number and clinical outcome. Methods: From April 2021 to July 2024, 278 MS patients (201 females, 77 males, mean age 47.01 ± 12.668 years) underwent brain MRI in three Italian Institutions using 1.5 T systems; 3D-FLAIR and 3D-DIR sequences were obtained with an identical anatomic position. Clinical disability was evaluated by the expanded disability state score (EDSS). Data analysis was performed using the Wilcoxon test for lesion count differences (primary endpoint), and Chi-square test and Spearman for EDSS correlation (secondary endpoint); a p < 0.05 was considered as statistically significant. Results: A significantly higher total number of lesions was displayed on DIR images (n = 6601) compared with FLAIR (n = 6484) (p < 0.001). The mean number of cortical lesions identified with DIR (1.56 ± 2.767) was significantly higher than the mean number of cortical lesions detected with FLAIR (0.52 ± 1.029) (p < 0.001). Conversely, FLAIR sequences detected a significantly higher mean number of subcortical lesions (9.34 ± 8.663) compared to DIR (8.94 ± 8.415) (p < 0.001). A significant correlation was found between EDSS and the number of juxtacortical and cortical lesions detected with DIR with a p < 0.001. Conclusions: 3D-DIR is superior to 3D-FLAIR in detecting cortical lesions, which are correlated to clinical disability, and it should be implemented for the diagnosis and prognostic evaluation in MS patients.

15 July 2025 in Anatomical Science International
Verified
Journal Article
Open access
PDF file
DBDenise Bonente
Denise Bonente
TTTiziana Tamborrino
Tiziana Tamborrino
NFNiccolò Fagni
Niccolò Fagni
SBSandra Bracco
Sandra Bracco
SLSara Leonini
Sara Leonini
EBeugenio Bertelli
eugenio Bertelli
The superior oblique muscle tendon is known to bend in the anterior orbit around a cartilaginous trochlea. The site where the tendon bends is frequently interested by the presence of a small depression, the trochlear fovea, and/or the trochlear spine. Exact topography, size and frequency of these items are still undetermined. For this purpose, we studied 120 orbits of individuals that underwent computed tomography for pathologies not involving the anterior orbit. We detected the presence of the trochlear spine in 10% of orbits and we determined its location and size. We also observed the presence of two tubercles (TT 1 and TT 2 ), with distinct positions relative to the tendon. TT 1 was present in 5% of orbits and was located on the same spot of the spine differing from the latter only for its morphology. TT 2 lied in a more advanced position and it was rarer (1,67% of orbits). The spine and the first type of tubercle were located above and behind the tendon reflection; the second tubercle lied below and ahead of the tendon reflection. A distinct trochlear fovea was detected in 25.83% of orbits and lied 3.42 ± 0.97 mm behind the orbital rim. Fovea diameters were 4.16 ± 1.08 mm × 3.84 ± 0.97 mm. In conclusion we demonstrate that in the anterior orbit a bony process is present in at least 15% or orbits. It is a note of interest for strabismus surgery when it is necessary to intervene on the superior oblique muscle or when it is needed access to the medial orbital wall.