Dileep Kumar

Mr. Dileep Kumar

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
DKDileep Kumar
Dileep Kumar
MAMorshed Alam
Morshed Alam
PZPatrick X.W. Zou
Patrick X.W. Zou
JSJay G. Sanjayan
Jay G. Sanjayan
RMRizwan Ahmed Memon
Rizwan Ahmed Memon

22 September 2022 in Cleaner Engineering and Technology
Verified
Journal Article
Open access
DKDileep Kumar
Dileep Kumar
Morshed AlamMorshed Alam
Morshed Alam
RMRizwan Ahmed Memon
Rizwan Ahmed Memon
BBBilawal Ahmed Bhayo
Bilawal Ahmed Bhayo

27 June 2019 in Journal of Building Physics
Verified
Journal Article
Closed access
PDF file
DKDileep Kumar
Dileep Kumar
PZPatrick X.W. Zou
Patrick X.W. Zou
RMRizwan Ahmed Memon
Rizwan Ahmed Memon
MAMorshed Alam
Morshed Alam
JSJay Sanjayan
Jay Sanjayan
SKSanjay Kumar
Sanjay Kumar
Heat transfer through building opaque envelope is responsible for approximately half of the total heat loss and gain to and from the surroundings. Therefore, insulation materials are commonly used in the building envelope to reduce the heat transfer. Recently, lightweight wall materials with lower thermal conductivity are used in construction along with the commonly used materials such as heavy concrete and earthen materials. In this perspective, there is a need to understand the optimum insulation thickness for different types of building construction materials to minimize unnecessary usage of insulation materials. This study investigated the optimum insulation thickness for different construction materials following a life-cycle approach, where an analytical optimization methodology based on the degree-days method and life-cycle cost analysis was used. In total, 4 insulation materials and 15 building construction materials were considered in the optimization study. The objective function was to minimize life-cycle cost corresponding to the decision variables including insulation thickness and the thermal conductivity of insulation and wall materials. The results showed that the use of insulation in lightweight wall materials is not economically feasible because of their negligible cost-saving potential (below US$2.5/m2-year). However, the walls with heavy concrete and earthen materials that have high thermal mass must be insulated due to their highest cost-saving potential (US$14–26.39/m2-year).

27 September 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
DKDileep Kumar
Dileep Kumar
Morshed AlamMorshed Alam
Morshed Alam
JSJay Sanjayan
Jay Sanjayan
Energy retrofitting the existing building stock is crucial to reduce thermal discomfort, energy consumption, and carbon emissions. However, insulating and enhancing the thermal mass of an existing building wall using traditional methods is a very challenging and expensive task. There is a need to develop a material that can be applied easily in an existing occupied building without much interruption to occupants’ daily life while also having high thermal resistance and heat storage capacity. This study aimed to investigate a potential building wall retrofit strategy combining aerogel render and Phase change materials (PCM) because aerogel render is highly resistive to heat and PCM has high thermal mass. While a number of studies investigated the thermal and energy-saving performances of aerogel render and PCM separately, no study has been done on the thermal and energy-saving performance of the combination of PCM and aerogel render. In this study, the performance of 12 different retrofit strategies, including aerogel and PCM, were evaluated numerically in terms of heat stress, energy savings, peak cooling, emission, and lifecycle cost using a typical single-story Australian house. The results showed that applying aerogel render and PCM on the outer side of the external walls and PCM and insulation in ceilings is the best option considering all performance indicators and ease of application. Compared to the baseline, this strategy reduced severe discomfort hours by 82% in a free-running building. In an air-conditioned building, it also decreased energy use, peak cooling demand, CO2 emission, and operational energy cost by 40%, 65%, 64%, and 35%, respectively. Although the lifecycle cost savings for this strategy were lower than the “insulated ceiling and rendered wall without PCM” case, the former one was considered the best option for its superior energy, emission, and comfort performance. Parametric analysis showed that 0.025 m is the optimum thickness for both PCM and aerogel render, and the 25 °C melting point PCM was optimum to achieve the best results amongst all performance indicators for a typical Australian house in Melbourne climate.

2 February 2023 in Energy and Buildings
Verified
Journal Article
Closed access
DKDileep Kumar
Dileep Kumar
MAMorshed Alam
Morshed Alam
JSJay Sanjayan
Jay Sanjayan

9 March 2023 in Buildings
Verified
Journal Article
Open access
PDF file
DKDileep Kumar
Dileep Kumar
Morshed AlamMorshed Alam
Morshed Alam
ADAbhijeet Jayeshbhai Doshi
Abhijeet Jayeshbhai Doshi
Phase change materials (PCM) are integrated into lightweight concrete (LWC) panels to increase their thermal mass. However, the integration of PCM into LWC also increases the thermal conductivity of the panels, which may have a negative impact. This study investigated the impact of thermal resistance and storage of LWC panels on thermal comfort and energy use in buildings. Six different LWC panels with varying levels of thermal conductivity and storage were developed using various combinations lightweight aggregates and PCM. The experimentally measured properties were used in building simulation software EnergyPlus V9.3 to calculate overheating and building energy consumption for each panel. The result showed that thermal mass influences severe discomfort hours more than thermal resistance. However, the level of influence depends on the position of the panels compared to the insulation layer. The presence of an insulation layer reduced the energy savings rate. The cooling energy consumption was more influenced by the thermal mass, whereas the heating was more influenced by the resistance of the wall. Overall, the LWC panel with the highest thermal mass was the best to reduce severe discomfort hours and energy consumption despite having the highest thermal conductivity. The outcome of this study can help to design an external building envelope with PCM panel as per user requirements, which could be to reduce overheating or cooling only, heating only, or both cooling and heating.