Reza Rasooli

Dr. Reza Rasooli

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
UDUmit Danis
Umit Danis
RRReza Rasooli
Reza Rasooli
Chia-Yuan ChenChia-Yuan Chen
Chia-Yuan Chen
ODOnur Dur
Onur Dur
MSMetin Sitti
Metin Sitti
KPKerem Pekkan
Kerem Pekkan
The motility mechanism of prokaryotic organisms has inspired many untethered microswimmers that could potentially perform minimally invasive medical procedures in stagnant fluid regions inside the human body. Some of these microswimmers are inspired by bacteria with single or multiple helical flagella to propel efficiently and fast. For multiple flagella configurations, the direct measurement of thrust and hydrodynamic propulsion efficiency has been challenging due to the ambiguous mechanical coupling between the flow field and mechanical power input. To address this challenge and to compare alternative micropropulsion designs, a methodology based on volumetric velocity field acquisition is developed to acquire the key propulsive performance parameters from scaled-up swimmer prototypes. A digital particle image velocimetry (PIV) analysis protocol was implemented and experiments were conducted with the aid of computational fluid dynamics (CFD). First, this methodology was validated using a rotating single-flagellum similitude model. In addition to the standard PIV error assessment, validation studies included 2D vs. 3D PIV, axial vs. lateral PIV and simultaneously acquired direct thrust force measurement comparisons. Compatible with typical micropropulsion flow regimes, experiments were conducted both for very low and higher Reynolds (Re) number regimes (up to a Re number = 0.01) than that are reported in the literature. Finally, multiple flagella bundling configurations at 0°, 90° and 180° helical phase-shift angles were studied using scaled-up multiple concentric flagella thrust elements. Thrust generation was found to be maximal for the in-phase (0°) bundling configuration but with ~50% lower hydrodynamic efficiency than the single flagellum. The proposed measurement protocol and static thrust test-bench can be used for bio-inspired microscale propulsion methods, where direct thrust and efficiency measurement are required.

27 August 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
RRReza Rasooli
Reza Rasooli
BCBarbaros Cetin
Barbaros Cetin
Inertial microfluidics is a promising tool for a label-free particle manipulation for microfluidics technology. It can be utilized for particle separation based on size and shape, as well as focusing of particles. Prediction of particles’ trajectories is essential for the design of inertial microfluidic devices. At this point, numerical modeling is an important tool to understand the underlying physics and assess the performance of devices. A Monte Carlo-type computational model based on a Lagrangian discrete phase model is developed to simulate the particle trajectories in a spiral microchannel for inertial microfluidics. The continuous phase (flow field) is solved without the presence of a discrete phase (particles) using COMSOL Multi-physics. Once the flow field is obtained, the trajectory of particles is determined in the post-processing step via the COMSOL-MATLAB interface. To resemble the operation condition of the device, the random inlet position of the particles, many particles are simulated with random initial locations from the inlet of the microchannel. The applicability of different models for the inertial forces is discussed. The computational model is verified with experimental results from the literature. Different cases in a spiral channel with aspect ratios of 2.0 and 9.0 are simulated. The simulation results for the spiral channel with an aspect ratio of 9.0 are compared against the experimental data. The results reveal that despite certain limitations of our model, the current computational model satisfactorily predicts the location and the width of the focusing streams.

15 April 2021 in Journal of Biomechanics
Verified
Journal Article
Open access
RRReza Rasooli
Reza Rasooli
MJMuhammad Jamil
Muhammad Jamil
MRMohammad Rezaeimoghaddam
Mohammad Rezaeimoghaddam
YYYahya Yıldız
Yahya Yıldız
ESEce Salihoglu
Ece Salihoglu
KPKerem Pekkan
Kerem Pekkan
Venovenous extracorporeal membrane oxygenation (VV-ECMO) is the preferred surgical intervention for patients suffering from severe cardiorespiratory failure, also encountered in SARS-Cov-2 management. The key component of VV-ECMO is the double-lumen cannula (DLC) that enables single-site access. The biofluid dynamics of this compact device is particularly challenging for neonatal patients due to high Reynolds numbers, tricuspid valve location and right-atrium hemodynamics. In this paper we present detailed findings of our comparative analysis of the right-atrial hemodynamics and salient design features of the 13Fr Avalon Elite DLC (as the clinically preferred neonatal cannula) with the alternate Origen DLC design, using experimentally validated computational fluid dynamics. Highly accurate 3D-reconstructions of both devices were obtained through an integrated optical coherence tomography and micro-CT imaging approach. Both cannula configurations displayed complex flow structures inside the atrium, superimposed over predominant recirculation regimes. We found that the Avalon DLC performed significantly better than the Origen alternative, by capturing 80% and 94% of venous blood from the inferior and superior vena cavae, respectively and infusing the oxygenated blood with an efficiency of more than 85%. The micro-scale geometric design features of the Avalon DLC that are associated with superior hemodynamics were investigated through 14 parametric cannula configurations. These simulations showed that the strategic placement of drainage holes, the smooth infusion blood stream diverter and efficient distribution of the venous blood capturing area between the vena cavae are associated with robust blood flow performance. Nevertheless, our parametric results indicate that there is still room for further device optimization beyond the performance measurements for both Avalon and Origen DLC in this study. In particular, the performance envelope of malpositioned cannula and off-design conditions require additional blood flow simulations for analysis.

3 February 2022 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
SLS Samaneh Lashkarinia
S Samaneh Lashkarinia
MCMurat Cicek
Murat Cicek
BKBanu Kose
Banu Kose
MRMohammad Rezaeimoghaddam
Mohammad Rezaeimoghaddam
EYEmine Hekim Yılmaz
Emine Hekim Yılmaz
ASAhmet Sasmazel
Ahmet Sasmazel
To evaluate the hemodynamicdynamic advantage of a new Fontan surgical template that is intended for complex single-ventricle patients with interrupted inferior vena cava-azygos and hemi-azygos continuation. The new technique has emerged from a comprehensive pre-surgical simulation campaign conducted to facilitate a balanced hepatic flow and somatic Fontan pathway growth after Kawashima procedure. For 9 patients, aged 2 to18 years, majority having poor preoperative oxygen saturation, a pre-surgical computational fluid dynamics customization is conducted. Both the traditional Fontan pathways and the proposed novel Y-graft templates are considered. Numerical model was validated against in vivo phase-contrast magnetic resonance imaging data and in vitro experiments. The proposed template is selected and executed for 6 out of the 9 patients based on its predicted superior hemodynamic performance. Pre-surgical simulations performed for this cohort indicated that flow from the hepatic veins (HEP) do not reach to the desired lung. The novel Y-graft template, customized via a right- or left-sided displacement of the total cavopulmonary connection anastomosis location resulted a drastic increase in HEP flow to the desired lung. Orientation of HEP to azygos direct shunt is found to be important as it can alter the flow pattern from 38% in the caudally located direct shunt to 3% in the cranial configuration with significantly reversed flow. The postoperative measurements prove that oxygen saturation increased significantly (P-value = 0.00009) to normal levels in 1 year follow-up. The new Y-graft template, if customized for the individual patient, is a viable alternative to the traditional surgical pathways. This template addresses the competing hemodynamic design factors of low physiological venous pressure, high postoperative oxygen saturation, low energy loss and balanced hepatic growth factor distribution possibly assuring adequate lung development. 25 October 2019, 280011928-604.01.01.

12 April 2022 in Journal of Biomechanics
Verified
Journal Article
Closed access
RRReza Rasooli
Reza Rasooli
BKBanu Kose
Banu Kose
SLSeyedeh Samaneh Lashkarinia
Seyedeh Samaneh Lashkarinia
ASAhmet Sasmazel
Ahmet Sasmazel
KPKerem Pekkan
Kerem Pekkan

17 January 2020 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
RRReza Rasooli
Reza Rasooli
YYYAHYA YİLDİZ
YAHYA YİLDİZ
MJMuhammad Jamil
Muhammad Jamil
KPKerem Pekkan
Kerem Pekkan
Clinical success of extracorporeal membrane oxygenation (ECMO) depends on the proper venous cannulation. Venovenous (VV) ECMO is the preferred clinical intervention as it provides a single-site access by utilizing a VV double lumen cannula (VVDLC) with a higher level of mobilization and physical rehabilitation. Concurrent venous blood drainage and oxygenated blood infusion in the right atrium at the presence of the cannula makes the flow dynamics complex where potential mixing of venous and oxygenated blood can drastically decrease the overall performance of ECMO. There are no studies focusing on the neonatal and pediatric populations, in which the flow related effects are critical due to the small atrium size. In this study, fluid dynamics of infusion outflow jet for two commercially available neonatal VVDLC is analyzed using particle image velocimetry (PIV). Moreover, six new designs are proposed for the infusion channel geometry and compared. Important flow parameters such as flow turning angle (FTA), velocity decay, potential core, and turbulent intensity are investigated for the proposed models. The experiments showed that the outflow parameters of commercial cannulae such as FTA are strongly dependent on the operating Re number. This may result in a drastic efficiency reduction for cannula operating at off-design flow conditions. Moreover, the infusion outlet tip structure and jet internal guiding pathway (JIGP) was observed to greatly affect the outflow flow features. This is of paramount importance since the anatomical positioning of the cannula and the infusion outlet is strongly dependent on the outflow properties such as FTA.