Ece Salihoglu

Ece Salihoglu

Auto-generated profile, based on publicly available information

Ece Salihoglu

Vice Rectorate, Istanbul Nişantaşi University, University of Istanbul-Cerrahpaşa, Istanbul, Turkey

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
EBEmre Belli
Emre Belli
ESEce Salihoğlu
Ece Salihoğlu
BLBertrand Leobon
Bertrand Leobon
FRFrançois Roubertie
François Roubertie
MLMohammed Ly
Mohammed Ly
ASAlain Serraf
Alain Serraf

14 May 2018 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
SLSeyedeh Samaneh Lashkarinia
Seyedeh Samaneh Lashkarinia
SPSenol Piskin
Senol Piskin
TBTijen A. Bozkaya
Tijen A. Bozkaya
ESEce Salihoglu
Ece Salihoglu
CYCan Yerebakan
Can Yerebakan
KPKerem Pekkan
Kerem Pekkan
Surgical treatment of congenital heart disease (CHD) involves complex vascular reconstructions utilizing artificial and native surgical materials. A successful surgical reconstruction achieves an optimal hemodynamic profile through the graft in spite of the complex post-operative vessel growth pattern and the altered pressure loading. This paper proposes a new in silico patient-specific pre-surgical planning framework for patch reconstruction and investigates its computational feasibility. The proposed protocol is applied to the patch repair of main pulmonary artery (MPA) stenosis in the Tetralogy of Fallot CHD template. The effects of stenosis grade, the three-dimensional (3D) shape of the surgical incision and material properties of the artificial patch are investigated. The release of residual stresses due to the surgical incision and the extra opening of the incision gap for patch implantation are simulated through a quasi-static finite-element vascular model with shell elements. Implantation of different unloaded patch shapes is simulated. The patched PA configuration is pressurized to the physiological post-operative blood pressure levels of 25 and 45 mmHg and the consequent post-operative stress distributions and patched artery shapes are computed. Stress–strain data obtained in-house, through the biaxial tensile tests for the mechanical properties of common surgical patch materials, Dacron, Polytetrafluoroethylene, human pericardium and porcine xenopericardium, are employed to represent the mechanical behavior of the patch material. Finite-element model is experimentally validated through the actual patch surgery reconstructions performed on the 3D printed anatomical stenosis replicas. The post-operative recovery of the initially narrowed lumen area and post-op tortuosity are quantified for all modeled cases. A computational fluid dynamics solver is used to evaluate post-operative pressure drop through the patch-reconstructed outflow tract. According to our findings, the shorter incisions made at the throat result in relatively low local peak stress values compared to other patch design alternatives. Longer cut and double patch cases are the most effective in repairing the initial stenosis level. After the patch insertion, the pressure drop in the artery due to blood flow decreases from 9.8 to 1.35 mmHg in the conventional surgical configuration. These results are in line with the clinical experience where a pressure gradient at or above 50 mmHg through the MPA can be an indication to intervene. The main strength of the proposed pre-surgical planning framework is its capability to predict the intra-operative and post-operative 3D vascular shape changes due to intramural pressure, cut length and configuration, for both artificial and native patch materials.

23 March 2018 in Artificial Organs
Verified
Journal Article
Open access
PDF file
JMJamil Muhammad
Jamil Muhammad
MRMohammad Rezaeimoghaddam
Mohammad Rezaeimoghaddam
BCBilgesu Cakmak
Bilgesu Cakmak
RRReza Rasooli
Reza Rasooli
ESEce Salihoglu
Ece Salihoglu
KPKerem Pekkan
Kerem Pekkan
Clinical success of pediatric veno‐venous (VV) extracorporeal membrane oxygenation (ECMO) is associated with the double lumen cannula cardiovascular device design as well as its anatomic orientation in the atrium. The positions of cannula ports with respect to the vena cavae and the tricuspid valve are believed to play a significant role on device hemodynamics. Despite various improvements in ECMO catheters, especially for the neonatal and congenital heart patients, it is still challenging to select a catalogue size that would fit to most patients optimally. In effect, the local unfavorable blood flow characteristics of the cannula would translate to an overall loss of efficiency of the ECMO circuit. In this study, the complex flow regime of a neonatal double lumen cannula, positioned in a patient‐specific right atrium, is presented for the first time in literature. A pulsatile computational fluid dynamics (CFD) solver that is validated for cardiovascular device flow regimes was used to perform the detailed flow, oxygenated blood transport, and site‐specific blood damage analysis using an integrated cannula and right atrium model. A standard 13Fr double lumen cannula was scanned using micro‐CT, reconstructed and simulated under physiologic flow conditions. User defined scalar transport equations allowed the quantification of the mixing and convection of oxygenated and deoxygenated blood as well as blood residence times and hemolysis build‐up. Site‐specific CFD analysis provided key insight into the hemodynamic challenges encountered in cannula design and the associated intra‐atrial flow patterns. Due to neonatal flow conditions, an ultra high velocity infusion jet emanated from the infusion port and created a zone of major recirculation in the atrium. This flow regime influenced the delivery of the oxygenated blood to the tricuspid valve. Elevated velocities and complex gradients resulted in higher wall shear stresses (WSS) particularly at the infusion port having the highest value followed by the aspiration hole closest to the drainage port. Our results show that, in a cannula that is perfectly oriented in the atrium, almost 38% of the oxygenated blood is lost to the atrial circulation while only half of the blood from inferior vena cava (IVC) can reach to the tricuspid valve. As such, approximately 6% of venous blood from superior vena cava (SVC) can be delivered to tricuspid. High values of hemolysis index were observed with blood damage encountered around infusion hole (0.025%). These results warrant further improvements in the cannula design to achieve optimal performance of ECMO and better patient outcomes.

1 January 2019 in Turkiye Klinikleri Journal of Medical Sciences
Verified
Journal Article
Open access
PDF file
BSBaris Sandal
Baris Sandal
YHYüksel Hacioğlu
Yüksel Hacioğlu
NYNurkan Yağiz
Nurkan Yağiz
ESEce Sali̇hoğlu
Ece Sali̇hoğlu
Objective: Determination of preanesthetic high risk during surgical procedures using fuzzy risk evaluation. Material and Methods: In this study for the high risk patient classification, five major criteria comprising cardiac, pulmonary, renal or liver diseases and diabetes mellitus and three minor criteria comprising patients' age, body mass index and cigarette smoking were chosen to define the high-risk group. Since the fuzzy logic gives the ability to use linguistic expressions, that include the intuition of human operators or experts during the decision making process, it this study by using fuzzy logic modelling, rules for high risks were developed. To reach this aim a new fuzzy logic decision system is proposed that uses four input variables to calculate the risk as a percentage that is the output of the fuzzy system. Results: Using Fuzzy risk evaluation; By taking into account the number of inputs and number of their corresponding membership functions, it is deduced that 270 fuzzy rules will be enough. Conclusion: In this study, a risk classification model was developed by combining the risk criteria defined by previous medical studies and clinical experience with a fuzzy logic model in the preoperative period. This developed fuzzy logic model needs to be investigated by selecting specific groups of patients and specific operations.

1 March 2003 in Asian Cardiovascular and Thoracic Annals
Verified
Journal Article
Closed access
PDF file
EEErsin Erek
Ersin Erek
YYYusuf Kenan Yalcinbas
Yusuf Kenan Yalcinbas
ESEce Salihoglu
Ece Salihoglu
NONilufer Ozturk
Nilufer Ozturk
SASevda Arat
Sevda Arat
TSTayyar Sarioglu
Tayyar Sarioglu
Newly developed stentless bioprostheses have shown good midterm results in the aortic position, but few data are available on their use at the right side of the heart. Four types of stentless bioprosthesis were used for right-side reconstruction of congenital heart anomalies in 50 patients (3 Baxter-Edwards Prima, 27 Medtronic Freestyle, 14 Cryolife Ross, and 6 Medtronic Contegra). Mean age was 9.03 ± 6.25 years. Serial Doppler echocardiographic studies were performed to evaluate transvalvular pressure gradients. The hospital mortality was 6%. Reoperation was required in 3 patients in the early postoperative period because of left ventricular outflow tract obstruction, endocarditis, or tricuspid insufficiency. Measurements from 34 patients were available for statistical analysis. Clinical follow-up was complete in 43 of the 47 hospital survivors; the mean follow-up period was 16.6 ± 16 months. Four patients died during follow-up; 93% of the survivors have an unrestricted lifestyle. Although peak transvalvular conduit gradients increased in all types of conduit, no reoperation has yet been performed for conduit stenosis. The newly developed stentless bioprostheses may be a useful alternative for right-side reconstruction of congenital heart anomalies.

15 April 2021 in Journal of Biomechanics
Verified
Journal Article
Open access
RRReza Rasooli
Reza Rasooli
MJMuhammad Jamil
Muhammad Jamil
MRMohammad Rezaeimoghaddam
Mohammad Rezaeimoghaddam
YYYahya Yıldız
Yahya Yıldız
ESEce Salihoglu
Ece Salihoglu
KPKerem Pekkan
Kerem Pekkan
Venovenous extracorporeal membrane oxygenation (VV-ECMO) is the preferred surgical intervention for patients suffering from severe cardiorespiratory failure, also encountered in SARS-Cov-2 management. The key component of VV-ECMO is the double-lumen cannula (DLC) that enables single-site access. The biofluid dynamics of this compact device is particularly challenging for neonatal patients due to high Reynolds numbers, tricuspid valve location and right-atrium hemodynamics. In this paper we present detailed findings of our comparative analysis of the right-atrial hemodynamics and salient design features of the 13Fr Avalon Elite DLC (as the clinically preferred neonatal cannula) with the alternate Origen DLC design, using experimentally validated computational fluid dynamics. Highly accurate 3D-reconstructions of both devices were obtained through an integrated optical coherence tomography and micro-CT imaging approach. Both cannula configurations displayed complex flow structures inside the atrium, superimposed over predominant recirculation regimes. We found that the Avalon DLC performed significantly better than the Origen alternative, by capturing 80% and 94% of venous blood from the inferior and superior vena cavae, respectively and infusing the oxygenated blood with an efficiency of more than 85%. The micro-scale geometric design features of the Avalon DLC that are associated with superior hemodynamics were investigated through 14 parametric cannula configurations. These simulations showed that the strategic placement of drainage holes, the smooth infusion blood stream diverter and efficient distribution of the venous blood capturing area between the vena cavae are associated with robust blood flow performance. Nevertheless, our parametric results indicate that there is still room for further device optimization beyond the performance measurements for both Avalon and Origen DLC in this study. In particular, the performance envelope of malpositioned cannula and off-design conditions require additional blood flow simulations for analysis.