Tomasz Figatowski

Dr. Tomasz Figatowski

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
WWWojciech Wańha
Wojciech Wańha
Mariusz TomaniakMariusz Tomaniak
Mariusz Tomaniak
PWPiotr Wańczura
Piotr Wańczura
JBJacek Bil
Jacek Bil
Rafał JanuszekRafał Januszek
Rafał Januszek
WWWojtek Wojakowski
Wojtek Wojakowski
Background: Whereas the efficacy and safety of intravascular lithotripsy (IVL) have been confirmed in de novo calcified coronary lesions, little is known about its utility in treating stent underexpansion. This study aimed to investigate the impact of IVL in treating stent underexpansion. Methods and Results: Consecutive patients with stent underexpansion treated with IVL entered the multicenter IVL-Dragon Registry. The procedural success (primary efficacy endpoint) was defined as a relative stent expansion >80%. Thirty days device-oriented composite endpoint (DOCE) (defined as a composite of cardiac death, target lesion revascularization, or target vessel myocardial infarction) was the secondary endpoint. A total of 62 patients were enrolled. The primary efficacy endpoint was achieved in 72.6% of patients. Both stent underexpansion 58.5% (47.5–69.7) vs. 11.4% (5.8–20.7), p < 0.001, and the stenotic area 82.6% (72.4–90.8) vs. 21.5% (11.1–37.2), p < 0.001, measured by quantitative coronary angiography improved significantly after IVL. Intravascular imaging confirmed increased stent expansion following IVL from 37.5% (16.0–66.0) to 86.0% (69.2–90.7), p < 0.001, by optical coherence tomography and from 57.0% (31.5–77.2) to 89.0% (85.0–92.0), p = 0.002, by intravascular ultrasound. Secondary endpoint occurred in one (1.6%) patient caused by cardiac death. There was no target lesion revascularization or target vessel myocardial infarction during the 30-day follow-up. Conclusions: In this real-life, largest-to-date analysis of IVL use to manage underexpanded stent, IVL proved to be an effective and safe method for facilitating stent expansion and increasing luminal gain.

1 September 2021 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
WWWojciech Wańha
Wojciech Wańha
JBJacek Bil
Jacek Bil
Rafał JanuszekRafał Januszek
Rafał Januszek
NGNatasza Gilis-Malinowska
Natasza Gilis-Malinowska
TFTomasz Figatowski
Tomasz Figatowski
WWWojciech Wojakowski
Wojciech Wojakowski
Background: Data regarding the use of percutaneous coronary intervention with drug-eluting balloons (DEB) versus thin-strut drug-eluting stents (thin-DES) for treating DES in-stent restenosis in everyday clinical practice is scarce. Our goal was to evaluate the efficacy and safety profile of DEB versus thin-DES in DES in-stent restenosis. Methods: Consecutive patients with DES in-stent restenosis who underwent percutaneous coronary intervention between 2008 and 2019 entered the multicenter DEB-DRAGON Registry with a follow-up of 3 years. Patients who received DEB at the index procedure (n=557, 49.9%) were compared with those who received thin-DES (n=560, 50.1%). Results: Analysis of the unmatched cohort revealed lower rates of target lesion revascularization (9.1% versus 13.6%; hazard ratio [HR], 0.58 [95% CI, 0.41–0.83], P =0.003), target vessel revascularization (11.8% versus 16.7%; HR, 0.62 [95% CI, 0.45–0.84], P =0.003) and device-oriented composite end point, defined as a composite of cardiac death, target lesion revascularization, and target vessel myocardial infarction (12.7% versus 16.0%; HR, 0.69 [95% CI, 0.50–0.94], P =0.018) in the thin-DES group compared with the DEB group. The incidence of cardiac death, target vessel-myocardial infarction, and myocardial infarction were similar in both groups. However, after propensity score matching, there were no significant differences in target lesion revascularization (11.2% versus 11.2%; HR, 0.91 [95% CI, 0.55–1.51], P =0.707), target vessel revascularization (13.4% versus 14.2%; HR, 0.86 [95% CI, 0.55–1.36], P =0.523), and device-oriented composite end point (14.2% versus 14.2%; HR, 0.91 [95% CI, 0.58–1.42], P =0.667) between the thin-DES and DEB group, respectively. Conclusions: This analysis of a real-life registry revealed similar long-term outcomes of thin-DES and DEB in DES in-stent restenosis regarding target lesion revascularization, myocardial infarction, cardiac death, and device-oriented composite end point. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04415216.

21 November 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JBJerzy Bartuś
Jerzy Bartuś
Rafał JanuszekRafał Januszek
Rafał Januszek
DHDamian Hudziak
Damian Hudziak
Michalina KołodziejczakMichalina Kołodziejczak
Michalina Kołodziejczak
ŁKŁukasz Kuźma
Łukasz Kuźma
WWWojciech Wańha
Wojciech Wańha
Data on the clinical outcomes comparing synthetic fluorocarbon polymer polytetrafluoroethylene- (PTFE, GraftMaster) and polyurethane- (Papyrus) covered stents (CSs) to seal coronary artery perforations (CAPs) are limited. We aimed to evaluate 30-day and 1-year clinical outcomes after PCI complicated by CAP and treated with CS. We assessed 106 consecutive patients with successful CAP sealing (122 CSs): GraftMaster (51 patients, 57 CSs) or Papyrus CS (55 patients, 65 CSs). The primary endpoint was the occurrence of major adverse cardiac events (MACE), defined as the composite of cardiac death, target lesion revascularisation (TLR), and myocardial infarction (MI). The mean age of subjects was 69 ± 9.6 years (53.8% males). No significant differences were identified between the GraftMaster and Papyrus groups at the 30-day follow-up for MACE, cardiac death, MI and stent thrombosis (ST), while significantly lower rate of TLR and TVR (p = 0.02) were confirmed in the Papyrus group. At one year, differences remained similar between stents for MACE, a trend towards a lower rate of TLR (p = 0.07), MI (p = 0.08), and ST (p = 0.08), and higher for cardiac death (p = 0.07) was observed in the Papyrus group. This real-life registry of CAP illustrated that the use of Papyrus CS is associated with lower rates of TLR and TVR at 30-day follow-up in comparison to the GraftMaster CSs and no significant differences between both assessed CS at one year of follow-up.

29 September 2023 in Cardiology Journal
Verified
Journal Article
Open access
PDF file
Ewelina BłażejowskaEwelina Błażejowska
Ewelina Błażejowska
JZJakub Zimodro
Jakub Zimodro
TFTomasz Figatowski
Tomasz Figatowski
ABAdam Brzeski
Adam Brzeski
TDTomasz Dziubich
Tomasz Dziubich
RTRadoslaw Targonski
Radoslaw Targonski

29 November 2025 in Metabolites
Verified
Journal Article
Open access
PDF file
TFTomasz Figatowski
Tomasz Figatowski
WKWiktoria Alicja Karos-Słomiak
Wiktoria Alicja Karos-Słomiak
JMJoanna Marlęga-Linert
Joanna Marlęga-Linert
LHLudmiła Hasak
Ludmiła Hasak
AKAgnieszka Kuchta
Agnieszka Kuchta
AMAgnieszka Mickiewicz
Agnieszka Mickiewicz
Background: Pathogenesis of aortic stenosis (AS) involves lipid infiltration, inflammation, and oxidative stress, which drive calcification of the aortic valve and progression to heart failure (HF). Fatty acids (FAs) play a crucial role in these processes. A treatment option for severe symptomatic AS in elderly and high-risk patients is transcatheter aortic valve implantation (TAVI). Objective: To investigate the change in FA profiles in patients undergoing TAVI. Methods: This single-center prospective study included 25 patients with severe AS qualified for TAVI procedure. Blood samples were collected before TAVI and after six months. FA profiles were analyzed by gas chromatography-electron ionization mass spectrometry. Results: Notable changes were identified in FA profiles, including a reduction in docosahexaenoic acid (DHA) levels (117 ± 48.0 µM vs. 141 ± 53.0 µM, p = 0.001) and an increase in alpha-linolenic acid (ALA) concentration (32.8 ± 12.3 µM vs. 19.9 ± 6.40 µM, p = 0.003) six months post-TAVI. Additionally, significant elevations were noted in specific medium-chain FAs (C12) and branched-chain fatty acids (iso C16, iso C17 and anteiso C15, anteiso C17) at six months after TAVI. However, total n-3 polyunsaturated fatty acids (n3 PUFA) levels decreased (p = 0.039), while n-6 polyunsaturated fatty acids (n6 PUFA) levels exhibited no significant overall change at this time point. Decrease in mean pressure gradient (PG) was negatively correlated with eicosapentaenoic acid (EPA), DHA, n-3 docosapentaenoic acid (DPA n3) and n3 PUFA levels in a six-month observation. Conclusions: Our results underscore the complex interplay between cardiac intervention and FA changes, providing novel insights into the metabolic impact of TAVI on FAs serum profile.