Xiuwei Li

Dr. Xiuwei Li

College of Power Engineering, Nanjing University of Science and Technology, Nanjing, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2018 in Catalysts
Verified
Journal Article
Open access
PDF file
FCFeng Cheng
Feng Cheng
Xiuwei LiXiuwei Li
Xiuwei Li
Firstly, this paper reviews two main methods for biochar synthesis, namely conventional pyrolysis and hydrothermal carbonization (HTC). The related processes are described, and the influences of biomass nature and reaction conditions, especially temperature, are discussed. Compared to pyrolysis, HTC has advantages for processing high-moisture biomass and producing spherical biochar particles. Secondly, typical features of biochar in comparison with other carbonaceous materials are summarized. They refer to the presence of inorganics, surface functional groups, and local crystalline structures made up of highly conjugated aromatic sheets. Thirdly, various strategies for biochar modification are illustrated. They include activation, surface functionalization, in situ heteroatom doping, and the formation of composites with other materials. An appropriate modification is necessary for biochar used as a catalyst. Fourthly, the applications of biochar-based catalysts in three important processes of biofuel production are reviewed. Sulfonated biochar shows good catalytic performance for biomass hydrolysis and biodiesel production. Biodiesel production can also be catalyzed by biochar-derived or -supported solid-alkali catalysts. Biochar alone and biochar-supported metals are potential catalysts for tar reduction during or after biomass gasification. Lastly, the merits of biochar-based catalysts are summarized. Biochar-based catalysts have great developmental prospects. Future work needs to focus on the study of mechanism and process design.

21 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FCFeng Cheng
Feng Cheng
Xiuwei LiXiuwei Li
Xiuwei Li
Co-doped and Ni-doped hematite (α-Fe2O3) nanorod arrays were prepared on fluorine-doped tin oxide (FTO) conductive glass via aqueous chemical growth, in which the doping and the formation of nanorods occurred simultaneously (i.e., in situ doping). These samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), ultraviolet (UV)–visible spectrophotometry, linear sweep voltammetry and Mott–Schottky (M–S) measurement. Results showed that the introduction of 5% Co or Ni into α-Fe2O3 (the molar ratio of dopant to Fe is 1:20) did not change its crystal phase, morphology, energy gap and flat band potential. Both the undoped and the doped α-Fe2O3 showed a direct band gap of 2.24 eV, an indirect band gap of 1.85 eV, and a flat band potential of −0.22 V vs. saturated calomel electrode (SCE). At an applied potential of 0.2 V vs. SCE, the Co-doped and the Ni-doped α-Fe2O3 exhibited a photocurrent of 1.28 mA/cm2 and 0.79 mA/cm2, respectively, which were 2.1 times and 1.3 times that of the undoped α-Fe2O3. After the Co or Ni doping, the charge carrier concentration increased from 1.65 × 1025 m−3 to 3.74 × 1025 m−3 and 2.50 × 1025 m−3, respectively. Therefore, the increase in the photocurrent of the doped α-Fe2O3 was likely attributed to their enhanced conductivity.

1 November 2017 in Procedia Engineering
Verified
Journal Article
Open access
PDF file
BDBoqing Ding
Boqing Ding
FCFeng Cheng
Feng Cheng
Xiuwei LiXiuwei Li
Xiuwei Li
The air-conditioning system, a huge energy consumer, must be more energy conservative and environment friendly for greener buildings. Absorption air-conditioning system is an idea option except for its low performance caused by the thermal regeneration method. That can be improved with the membrane regeneration based on electrodialysis method. However, single-stage membrane regeneration is unstable and inefficient when the concentration difference is high. Double-stage membrane system can solve the problem. Theoretical and experimental work has been done about double-stage system: Models have been developed based on the mass and energy balance equations. Analysis has been made on some influential parameters. Experiments have been conducted to test the true regeneration performance. It has revealed the influences of the solute concentration, voltages and the transferred solute mass. The experimental results show double-stage system could be a better choice as the concentration difference decreases in regenerators. Under some conditions, the maximum coefficient of performance (COP) of double-stage system can as high as 3.

6 February 2024 in Applied Thermal Engineering
Verified
Journal Article
Closed access
YGYuting Guo
Yuting Guo
LYLing Yuan
Ling Yuan
FCFeng Cheng
Feng Cheng
Xiuwei LiXiuwei Li
Xiuwei Li

1 March 2021 in Processes
Verified
Journal Article
Open access
PDF file
FCFeng Cheng
Feng Cheng
YWYunlei Wu
Yunlei Wu
Xiuwei LiXiuwei Li
Xiuwei Li
Absorption air-conditioning systems have a great advantage in terms of energy conservation and environmental protection. However, the large amount of energy waste in the thermal regeneration process leads to lower efficiency and impedes its development. To reduce energy loss and improve performance, a local heating regeneration method is proposed in this paper. The main principle is reducing the volume of the liquid participating regeneration. Including the solar steam mode, two modes are introduced and configured. Theoretical and experimental research has been made on the new methods. Models have been developed for comparison analysis. Experiments have been conducted on water and absorbent solution with different modes. Performance has been evaluated based on the experimental data. The results expose the influence of different parameters, like liquid volume and solution concentration, on the regeneration process. The local heating method improved the regeneration efficiency by 40% in the no solar steam mode and the performance tripled in the solar steam mode. The COP (the ratio of cooling load to energy consumption) of the absorption system with the solar steam mode is more than two times of that with the traditional regeneration mode. It shows the local heating regeneration method has good potential in future application.

22 February 2021 in Processes
Verified
Journal Article
Open access
PDF file
FCFeng Cheng
Feng Cheng
BDBoqing Ding
Boqing Ding
Xiuwei LiXiuwei Li
Xiuwei Li
An absorption air-conditioning system is a good choice for green buildings. It has the superiority in the utilization of renewable energy and the refrigerant is environment-friendly. However, the performance of the traditional absorption system has been restricted by the energy waste in the thermal regeneration process. Capacitive deionization (CDI) regeneration is proposed as a potential method to improve system efficiency. In the new method-based air-conditioning system, strong absorbent solutions and pure water are acquired with the joint work of two CDI units. Nevertheless, the practical CDI device is composed of a lot of CDI units, which is quite different from the theoretical model. To reveal the performance of multiple CDI units, the model of the double/multi-stage CDI system has been developed. Analysis has been made to expose the influence of some key parameters. The results show the double-stage system has better performance than the single-stage system under certain conditions. The coefficient of performance (COP) could exceed 4.5, which is higher than the traditional thermal energy-driven system, or even as competitive as the vapor compression system. More stages with proper voltage distribution better the performance. It also provides the optimization method for the multi-stage CDI system.