Zeng Xiangjun

Dr. Zeng Xiangjun

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ZXZeng Xiangjun
Zeng Xiangjun
HZHu Zihan
Hu Zihan
XLXia Lingqin
Xia Lingqin
FCFeng Chen
Feng Chen
YMYang Ming
Yang Ming
The problem of data imbalance is widely present in wind turbine (WT) gearbox fault diagnosis, resulting in significant differences in diagnostic accuracy for majority and minority classes. To address this challenge, an improved conditional generative adversarial network (ICGAN) was proposed to mitigate the impact of imbalanced data on fault diagnosis. The ICGAN uses a one-dimensional convolutional neural network to extract feature vectors rich in detailed information from real samples as conditional signals. This enhances the learning ability of the generator for intrinsic patterns and structures in the data, ensuring that the generated data not only contains the intrinsic features of real samples but also meets specific condition requirements. Additionally, considering that Gaussian mixture models (GMM) can effectively capture the multimodal characteristics of signals, ICGAN uses the signals synthesized by GMM as the generator inputs, enabling the generator to cover more sample space and increase the diversity of generated samples. Moreover, the GMM can adaptively adjust parameters according to the feedback of the discriminator to improve the adaptability of the generator to the data, thereby enhancing the generalization performance of the ICGAN. The Wasserstein distance and Bayesian optimization algorithm are also used to improve the stability and efficiency of model training. Experiments show that the data generated by ICGAN is more similar to real samples compared to other GAN-based models. Using the vibration data generated by ICGAN for multi-class fault diagnosis of real WT gearbox, the average diagnostic accuracy can reach 94%, with the accuracy for minority classes also reaching 92%.

2 January 2025 in Processes
Verified
Journal Article
Open access
PDF file
ZHZihan Hu
Zihan Hu
ZXZeng Xiangjun
Zeng Xiangjun
FCFeng Chen
Feng Chen
HDHaoran Diao
Haoran Diao
The grid ancillary service capability of bus swapping stations (BSSs) is significantly affected by environmental temperature fluctuations and the disorderly charging and discharging of batteries. This study addressed these challenges by developing a comprehensive optimization model for scheduling BSS operations under varying environmental conditions. First, based on real-world energy consumption and temperature data, an energy consumption coefficient correction method was proposed to improve the accuracy of energy consumption calculations. Next, a greedy strategy was utilized to match vehicle battery swapping demands with available batteries in the BSS. A two-layer multi-objective optimization model was then constructed to optimize the charging and discharging power. The upper layer minimizes the total costs, including charging/discharging costs and battery degradation costs, while the lower layer minimizes the load peak-valley difference and maximizes the charging/discharging balance among all batteries. Numerical simulations of the proposed energy consumption correction coefficient improved the accuracy of electric bus energy consumption estimation. Additionally, the proposed optimization strategy reduced the operational cost of the bus battery swapping station by 53.09% and decreased the transformer’s maximum load rate by 28.28%.

1 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
FCFeng Chen
Feng Chen
LNLong Ni
Long Ni
YLYunfeng Lan
Yunfeng Lan
HZHuizhong Zheng
Huizhong Zheng
ZXZeng Xiangjun
Zeng Xiangjun
In coal mine non-solidly grounded systems, high-impedance faults generate minimal zero-sequence currents with obscured characteristics and strong interference, complicating faulted line identification. Existing methods rarely address three-phase imbalance and variable cable parameters, causing selection errors. To this end, a method for identifying the non-effective ground fault routing of mining cables based on Steady-State Impedance Analysis (SSIA) and Holmes–Duffing oscillator small-signal detection is proposed. Firstly, based on SSIA, the mapping relationship that the phase of the zero-sequence current variation in the faulted line is the same as the phase of its voltage relative to the faulted ground is derived before and after the occurrence of the fault. Meanwhile, identifiable differences exist in both phase and amplitude of the zero-sequence current change in faulty lines compared to non-faulty lines before and after fault occurrence. This is used as the criterion for high-impedance ground fault line selection. In the mining environment, zero-sequence current variations are characterized as weak signals, which poses significant challenges for detection. Thus, a Holmes–Duffing oscillator weak signal detection method is proposed. Based on chaotic principles, accurate line selection is achieved by diagnosing chaotic states in oscillator-generated phase trajectories. A specific mine grid simulation via MATLAB/Simulink 2023b validates the method’s efficacy and applicability.