This paper reports the results of heat transfer during refrigerant flow in rectangular mini-channels at stationary conditions. The impacts of selected parameters on boiling are discussed, i.e., thermal and flow parameters, dimensions and orientation of the channels. Four refrigerants (FC-72, HFE-649, HFE-7000 and HFE-7100) were used as the working fluid. Research was carried out on the experimental set-up with the test section with a single rectangular mini-channel of 180 mm long and with a group of five parallel mini-channels, each 32 mm long. The temperature of the mini-channel’s heated wall was measured by infrared thermography. Local values of the heat transfer coefficient at the contact surface between the fluid and the plate were calculated using the 1D mathematical method. The results are presented as the relationship between the heat transfer coefficient and the distance along the mini-channel length and boiling curves. Two-phase flow patterns are shown. Moreover, the results concerning various refrigerants and the use of modified heater surfaces are discussed. The main factors influencing the heat transfer process were: mini-channel inclination to the horizontal pane (the highest heat transfer coefficient at 270° and 0°), using modified heater surfaces (especially electroerosion texturing and vibration-assisted laser No. 2 texturing) and working fluids (FC-72 and HFE-7000).
The process with change of phase during flow in mini-channels plays a significant role in many industrial applications, such as microelectronics. Furthermore, methods for heat transfer intensification during flow in channels of small cross-section are still being sought. In this work, studies of the effect of using a modified heated surface on intensification boiling heat transfer in rectangular mini-channels during upward and downward flow are performed. The test section of a group of seven parallel mini-channels 1 mm deep was investigated during the subcooled and saturated flow boiling of FC-72. The temperature of the outer heated wall surface was measured using an infrared camera. During the experiments, two-phase flow structures were captured with a quick camera. Local heat transfer coefficients at the contact surface between the working fluid and the heated surface were determined with the use of a one-dimensional calculation method. To present the results, local temperature measurements and heat transfer coefficients, boiling curves and two-phase flow patterns are shown and analyzed. The results concerning two directions of vertical flow along mini-channels are discussed. Several modified heated surfaces and one smooth were tested for comparison. The main objective was to find out how the modified surface of the heated wall can intensify boiling heat transfer with upward and downward refrigerant flow in mini-channels of rectangular cross-section.
The paper discusses the results of the flow boiling heat transfer in a vertical minichannel with rectangular cross-section. The heating element for FC-72 flowing in the minichannel is a thin plate. Infrared thermography is used to determine changes in the temperature on its outer side. The aim of thecalculation is to determine the heat transfer coefficient using 1D and 2D calculation models. Local values of heat transfer coefficient on the surface between the heated plate and boiling fluid are calculated from the Newton`s and Fourier`s laws. In 2D model the plate temperature distribution is obtained by solving the inverse heat conduction problem. The governing equation is solved by means of two methods: the non-continuous Trefftz method and the Beck method. The results are presented as plate temperature and heat transfer coefficient calculated using 1D and 2D models as a function of the distance fromthe minichannel inlet. The analysis of the results revealed that the values and distributions of the heat transfer coefficient calculated by means of both models were similar. This suggests that all mentioned methods are interchangeable.
The paper reports results for flow boiling heat transfer in a 1.7 mm deep minichannel vertically-oriented with upward and downward flow. The heated element for HFE-649 flowing upward or downward in a channel was a smooth plate. Infrared thermography allowed determining changes in temperature on the outer plate side. Two-phase flow structures were recorded through a glass pane at the other side of the channel being in contact with the fluid. Analysis of the results was performed on the basis of experimental series obtained for the same heat flux for upward and downward flows and two mass flow velocities. The results are presented as relationships between the heat transfer coefficient or the plate temperature and the channel length, boiling curves, and between the heat flux and the heat transfer coefficient and two-phase flow structure images. The impact of mass flow velocity on the heat transfer coefficient and two-phase flow structures for vertical upward and downward flows were discussed.
This study investigates the effects of using laser-textured surfaces in boiling heat transfer during cooling fluid flow in a minichannel. Several laser-textured surfaces, varied in roughness, were created on the heated plate surface that contacted FC-72 during flow in a single minichannel. Infrared thermography was used to measure temperature changes on the untextured side of the plate, while two-phase flow patterns were observed through a glass pane. Three vibration-assisted laser surface textures, previously investigated by the authors, and five novel laser surface textures were tested experimentally. The results were presented as relationships between heated wall temperature, heat transfer coefficient and distance along the minichannel, boiling curves, and flow patterns. The main interest of the authors was to provide a comparative analysis of the heat transfer results at the same value of heat flux supplied to the minichannel heated wall when either a laser-textured surface or a smooth base one was applied. It was noticed that the use of the 90-degree dense grid pattern type 2 (shallow) surface in the research helped achieve the highest local heat transfer coefficient in the subcooled boiling region compared to other surfaces tested. Furthermore, the 90-degree dense grid pattern type 1, characterised by larger maximum depth and height surfaces, performed best in the saturated boiling region. The results obtained for the laser-textured heated plate surface were compared to those collected for the smooth base heated plate surface, generally indicating an intensification of heat transfer processes in boiling heat transfer during FC-72 flow in a minichannel.
This study presents comprehensive experimental, analytical, and numerical analyses of heat transfer during countercurrent flow of Fluorinert FC-72 and distilled water within a multi-mini-channel (MMCH) module under steady-state conditions. The experimental investigation was conducted in a test section inclined at an angle of 165 degrees relative to the horizontal plane, utilizing an infrared camera to measure the external temperature of the heated mini-channel (MCH) wall. The test module comprised twelve MCHs: six hot (HMCH) and six cold mini-channels (CMCH), each with a rectangular cross-section. The dimensions of each MCH are 140 mm in length, 18.3 mm in width, and 1.5 mm in depth, with a hydraulic diameter of dh = 2.77 mm. The heating system on the top wall of the external heated copper comprises a halogen heating lamp. Results include infrared thermographs, temperature distributions, and heat transfer coefficients (HTCs) along the channels. Local HTCs were calculated using a one-dimensional (1D) approach, a simple analytical method, at interfaces such as the heated plate—HMCHs, HMCHs—separating plate, separating plate—CMCHs, and CMCHs—closing plate. CFD simulations conducted with Simcenter STAR-CCM+ incorporated empirical data from experiments, using parameters like temperature, pressure, velocity profiles, and heat flux density to determine HTCs. The maximum difference between the 1D method and CFD results was 29% at the HMCHs/separating plate interface. In comparison, the minimum was 13.5% at the separating plate/CMCHs interface, with an average across all channels and heat flux densities.