Dariusz Strąk

Mr. Dariusz Strąk

Faculty of Mechatronics and Mechanical Engineering, Kielce University of Technology
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2023 in The Archives of Automotive Engineering - Archiwum Motoryzacji
Verified
Journal Article
Open access
Dariusz StrąkDariusz Strąk
Dariusz Strąk
The first autonomous car was developed in the 1980s, but it wasn't until the early 2010s that the technology began to gain significant attention and investment. In 2010, Google began testing self-driving cars on public roads, and since then, many other companies have joined the race to develop...

16 July 2018 in Materials Research Proceedings
Verified
Conference Paper
Open access
PDF file
KSK. Strąk
K. Strąk
MPM. Piasecka
M. Piasecka
Dariusz StrąkDariusz Strąk
Dariusz Strąk

12 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
Magdalena PiaseckaMagdalena Piasecka
Magdalena Piasecka
SHSylwia Hożejowska
Sylwia Hożejowska
APAnna Pawińska
Anna Pawińska
Dariusz StrąkDariusz Strąk
Dariusz Strąk
This paper presents the results of research on heat transfer during fluid flow in a heat exchanger with two rectangular mini-channels. There was Fluorinert FC-72 flow, heated by the plate in the hot mini-channel, and co-current flow of distilled water in the cold mini-channel. Both fluids were separated by the copper plate. A thermal imaging camera was used to measure the temperature distribution of the outer surface of the heated plate. The purpose of the calculations was to determine the heat transfer coefficients at the contact surfaces: the heated plate—FC-72 and FC-72—the copper plate. Two mathematical models have been proposed to describe the heat flow. In the 1D approach, only the heat flow direction perpendicular to the fluid flow direction was assumed. In the 2D model, it was assumed that the temperature of the heated plate and FC-72 and the copper plate meet the appropriate energy equation, supplemented by the boundary conditions system. In this case, the Trefftz functions were used in numerical calculations. In the 1D model, the heat transfer coefficient at the interface between FC-72 and the copper plate was determined by theoretical correlations. The analysis of the results showed that the values and distributions of the heat transfer coefficient determined using both models were similar.

15 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
KSKinga Strąk
Kinga Strąk
Dariusz StrąkDariusz Strąk
Dariusz Strąk
This study presents comprehensive experimental, analytical, and numerical analyses of heat transfer during countercurrent flow of Fluorinert FC-72 and distilled water within a multi-mini-channel (MMCH) module under steady-state conditions. The experimental investigation was conducted in a test section inclined at an angle of 165 degrees relative to the horizontal plane, utilizing an infrared camera to measure the external temperature of the heated mini-channel (MCH) wall. The test module comprised twelve MCHs: six hot (HMCH) and six cold mini-channels (CMCH), each with a rectangular cross-section. The dimensions of each MCH are 140 mm in length, 18.3 mm in width, and 1.5 mm in depth, with a hydraulic diameter of dh = 2.77 mm. The heating system on the top wall of the external heated copper comprises a halogen heating lamp. Results include infrared thermographs, temperature distributions, and heat transfer coefficients (HTCs) along the channels. Local HTCs were calculated using a one-dimensional (1D) approach, a simple analytical method, at interfaces such as the heated plate—HMCHs, HMCHs—separating plate, separating plate—CMCHs, and CMCHs—closing plate. CFD simulations conducted with Simcenter STAR-CCM+ incorporated empirical data from experiments, using parameters like temperature, pressure, velocity profiles, and heat flux density to determine HTCs. The maximum difference between the 1D method and CFD results was 29% at the HMCHs/separating plate interface. In comparison, the minimum was 13.5% at the separating plate/CMCHs interface, with an average across all channels and heat flux densities.

11 July 2022 in EPJ Web of Conferences
Verified
Journal Article
Open access
PDF file
Dariusz StrąkDariusz Strąk
Dariusz Strąk
MPMagdalena Piasecka
Magdalena Piasecka
In the paper, a new construction of a compact plate heat exchanger dedicated to PVT cooling was numerically tested. The efficiency of photovoltaic panels decreases as their temperature increases, but cooling improves efficiency. A model counter-current heat exchanger with rectangular minichannels was presented. A heated wall of the heat exchanger was a photovoltaic cell. There were laminar flows of Fluorinert FC-72 and distilled water in the minichannels. FC-72 was heated by the photovoltaic panel. The CAD model of a minichannel heat exchanger was proposed. CFD calculations were performed using Simcenter STAR-CCM+ software. The fluid temperature and velocity profile in the minichannels were determined to finally obtain the values of the heat transfer coefficient. The main parameters taken into consideration in the computations concerned: meshes, physics, and geometry. Finally, local heat transfer coefficients were determined.

3 December 2018 in E3S Web of Conferences
Verified
Conference Paper
Open access
Dariusz StrąkDariusz Strąk
Dariusz Strąk
KSKinga Strąk
Kinga Strąk
Magdalena PiaseckaMagdalena Piasecka
Magdalena Piasecka
The main aim of this work is to propose a new system of a hybrid photovoltaic system working with batteries and supercapacitors and to analyze its efficiency. The preliminary results of the study on the operation of the system are discussed. The results obtained while testing the operation of a hybrid system and a PV system working separately with batteries and supercapacitors are compiled and compared. The tests covered the systems efficiency for the following electrical loads: heater warming up water in a tank, and lighting - a LED light. The work of batteries and supercapacitors during discharge has been analysed. The use of a hybrid system made it possible to increase energy storage efficiency and the system operation flexibility, compared to solar systems offered by the sector.