Jayesh Adhikari

Mr. Jayesh Adhikari

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Biomicrofluidics
Verified
Journal Article
Closed access
VJVeerendra Kalyan Jagannadh
Veerendra Kalyan Jagannadh
JAJayesh Adhikari
Jayesh Adhikari
SGSai Siva Gorthi
Sai Siva Gorthi
In this work, we report a system-level integration of portable microscopy and microfluidics for the realization of optofluidic imaging flow analyzer with a throughput of 450 cells/s. With the use of a cellphone augmented with off-the-shelf optical components and custom designed microfluidics, we demonstrate a portable optofluidic imaging flow analyzer. A multiple microfluidic channel geometry was employed to demonstrate the enhancement of throughput in the context of low frame-rate imaging systems. Using the cell-phone based digital imaging flow analyzer, we have imaged yeast cells present in a suspension. By digitally processing the recorded videos of the flow stream on the cellphone, we demonstrated an automated cell viability assessment of the yeast cell population. In addition, we also demonstrate the suitability of the system for blood cell counting.

7 January 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
GEGangadhar Eluru
Gangadhar Eluru
JAJayesh Adhikari
Jayesh Adhikari
PCPriyalaxita Chanda
Priyalaxita Chanda
SGSai Siva Gorthi
Sai Siva Gorthi
The pumping of fluids into microfluidic channels has become almost an unavoidable operation in all microfluidic applications. Such a need has seen an outburst of several techniques for pumping, out of which the majority of techniques involve complicated fabrication, as they require the introduction of electrodes, valves, piezoelectric materials, acoustic transducers, etc., into the microfluidic device. In addition to the complexity, this also escalates the cost incurred per device. Further, the use of stable external power supplies to produce such a pumping action adds to the bulkiness of the pumps, making them unsuitable for point-of-care diagnostic (POCD) applications. This paper reports a technique of pumping that is simple to realize and does not require external electric/magnetic power, but exploits the elastic properties of materials to achieve the pumping action. This mechanism of pumping ensured the cost per pump to less than 4 USD and can be used for at least 500 times. Several simulations, validation, and characterization experiments were performed on the developed pump to establish its functionality and suitability for use in POCD applications.

1 February 2017 in SLAS Technology
Verified
Journal Article
Open access
APAbhishek Pathak
Abhishek Pathak
JBJayant Borana
Jayant Borana
JAJayesh Adhikari
Jayesh Adhikari
SGSai Siva Gorthi
Sai Siva Gorthi
In this article, we report on the development of indicator-impregnated agarose sensor films for colorimetric estimation of the pH of different standard buffer solutions and urine samples. In contrast to the conventional paper-based dipstick method, the presented method employs dried agarose that was infused with a chemical indicator, which when exposed to the test sample results in an appropriate chromogenic outcome. The color change was then quantified by the smart camera system. The divulged instrument has been calibrated with standard buffers and also tested with clinical urine samples. The systematic study was conducted to characterize the performance of the presented technique, such as interplate variations, time variations, volume variations, and shelf life study of agarose sensor films for the commercial viability of such a technique. The employed method is competent enough to bring a change in the paradigm of dipstick method from being qualitative estimation to quantitative, manual detection to automated, and a subjective approach of diagnosis to an objective one. The technique presented here has potential application in the field of point-of-care diagnostics with high fidelity, multiplexing, and robust quantitative estimation.

1 February 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
SMSwetha Murali
Swetha Murali
JAJayesh Adhikari
Jayesh Adhikari
VJVeerendra Kalyan Jagannadh
Veerendra Kalyan Jagannadh
SGSai Siva Gorthi
Sai Siva Gorthi
Cost-effective and automated acquisition of whole slide images is a bottleneck for wide-scale deployment of digital pathology. In this article, a computation augmented approach for the development of an automated microscope slide scanner is presented. The realization of a prototype device built using inexpensive off-the-shelf optical components and motors is detailed. The applicability of the developed prototype to clinical diagnostic testing is demonstrated by generating good quality digital images of malaria-infected blood smears. Further, the acquired slide images have been processed to identify and count the number of malaria-infected red blood cells and thereby perform quantitative parasitemia level estimation. The presented prototype would enable cost-effective deployment of slide-based cyto-diagnostic testing in endemic areas.

1 October 2018
Verified
Conference Paper
Closed access
RWRobert Wodnicki
Robert Wodnicki
HKHaochen Kang
Haochen Kang
JAJayesh Adhikari
Jayesh Adhikari
HJHayong Jung
Hayong Jung
Ruimin ChenRuimin Chen
Ruimin Chen
KFKatherine Ferrera
Katherine Ferrera
Tiled modular 2D ultrasound arrays have the potential for realizing large apertures for novel diagnostic applications. Here we present the results of recent work for fabrication of a tileable 2D array module implemented using a 1-3 composite of high bandwidth PIN-PMN-PT material closely coupled with high voltage CMOS ASICs for buffering and multiplexing functions. The 2D transducer array is supported by a 3D printed conducting and acoustically attenuating interposer backing which links the array to a PCB housing the interface ASICs. A novel low temperature approach for assembly of the acoustic modules to the printed circuit board utilizing conductive adhesive is presented. The fabricated module consists of an array of 6 × 20 elements at 600 μm pitch in azimuth, and 1600 μm pitch in elevation. The combined acoustic electric assembly displayed excellent overall fractional bandwidth of 81% for the functional elements, high element yield of 93%, and had a center frequency of 3.5 MHz, and -20 dB pulse length of 850 ns. The device was interfaced to a Verasonics Vantage 128 ultrasound system using an FPGA controller, and images were acquired using an industry standard tissue mimicking phantom.

1 September 2017
Verified
Conference Paper
Closed access
RWRobert Wodnicki
Robert Wodnicki
HKHaochen Kang
Haochen Kang
RZRui Zhang
Rui Zhang
Ruimin ChenRuimin Chen
Ruimin Chen
NCNestor Cabrera-Munoz
Nestor Cabrera-Munoz
KFKatherine Ferrera
Katherine Ferrera
In this paper, we describe process development and initial results for a tileable 2D array module for implementation of large area arrays. The module is based on a 1-3 composite of single crystal PIN-PMN-PT transducer material which benefits from improved electromechanical coupling coefficient k33' and increased Curie temperature. The backing for the array consists of a novel 3D printed acrylic frame that is filled with conducting and acoustically absorbing silver epoxy material. This interposer backing effectively connects each of the 2D array elements to respective signal channel connections on a supporting substrate. The substrate at present consists of a printed circuit board with a pitch-matched array of pads, however in the future it is intended to be replaced with ASIC electronics implementing switching and buffering functions for the 2D array. We fabricated sub-arrays as well as a full array module. Testing by micro-probing showed an average fractional bandwidth of 61% on the full module, and 87% on the sub-array elements. In future work, we plan to implement an imaging array by grouping a number of individual array modules and interfacing these to an ultrasound system.