Nasser M Alzahrani

Dr. Nasser M Alzahrani

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2021 in European Radiology
Verified
Journal Article
Open access
PDF file
NANasser M Alzahrani
Nasser M Alzahrani
AJAnnmarie Jeanes
Annmarie Jeanes
MPMichael Paddock
Michael Paddock
FSFarag Shuweihdi
Farag Shuweihdi
AOAmaka C. Offiah
Amaka C. Offiah
Objectives: To assess the diagnostic performance of chest CT in the detection of rib fractures in children investigated for suspected physical abuse (SPA). Methods: Medline, Web of Science and Cochrane databases were searched from January 1980 to April 2020. The QUADAS-2 tool was used to assess the quality of the eligible English-only studies following which a formal narrative synthesis was constructed. Studies reporting true-positive, false-positive, true-negative, and false-negative results were included in the meta-analysis. Overall sensitivity and specificity of chest CT for rib fracture detection were calculated, irrespective of fracture location, and were pooled using a univariate random-effects meta-analysis. The diagnostic accuracy of specific locations along the rib arc (anterior, lateral or posterior) was assessed separately. Results: Of 242 identified studies, 4 met the inclusion criteria. Of these, 2 were included in the meta-analysis. Chest CT identified 142 rib fractures compared to 79 detected by initial skeletal survey chest radiographs in live children with SPA. Post-mortem CT (PMCT) has low sensitivity (34%) but high specificity (99%) in the detection of rib fractures when compared to the autopsy reference standard. PMCT has low sensitivity (45%, 21% and 42%) but high specificity (99%, 97% and 99%) at anterior, lateral and posterior rib locations, respectively. Conclusions: Chest CT detects more rib fractures than initial skeletal survey chest radiographs in live children with SPA. PMCT has low sensitivity but high specificity for detecting rib fractures in children investigated for SPA. Key Points: • PMCT has low sensitivity (34%) but high specificity (99%) in the detection of rib fractures; extrapolation to CT in live children is difficult. • No studies have compared chest CT with the current accepted practice of initial and follow-up skeletal survey chest radiographs in the detection of rib fractures in live children investigated for SPA.

15 December 2022 in Pediatric Radiology
Verified
Journal Article
Open access
PDF file
NANasser M Alzahrani
Nasser M Alzahrani
MPMichael Paddock
Michael Paddock
AJAnnmarie Jeanes
Annmarie Jeanes
FSFarag Shuweihdi
Farag Shuweihdi
AOAmaka C. Offiah
Amaka C. Offiah
Background: The knowledge, awareness and professionalism of health care providers in the field of child protection are crucial in identifying and reporting suspected child abuse. Radiologic technologists and radiologists play a vital role in the diagnosis of suspected physical child abuse. Objective: To assess current practice, knowledge and awareness of child abuse among radiologic technologists and radiologists in Saudi Arabia. Materials and methods: We distributed an internet-based questionnaire to radiologic technologists and radiologists working in Saudi Arabia via national radiology societies and social media channels over a 6-week period (27 October to 8 December 2021). Survey questions covered knowledge regarding child abuse, professional practice in radiology departments in Saudi Arabia in cases of suspected physical abuse (SPA), and knowledge of the national legislation and reporting and acting procedures in child abuse. Results: A total of 315 respondents (224 radiologic technologists and 91 radiologists) participated in this study. The median score for knowledge of abuse was higher amongst radiologists (4.8) than radiologic technologists (4.0); P < 0.001. In total, 210 (93.8%) radiologic technologists and 61 (67.0%) radiologists reported that there was no protocol (i.e. skeletal survey) at their hospital for imaging children with SPA. Most radiologic technologists had no training in paediatric radiology (165/224, 73.7%) and most radiologists had received no training in evaluating imaging performed for SPA (73/91, 80.2%). More than half of respondents — 131 (58.5%) radiologic technologists and 44 (48.4%) radiologists — were not familiar with the reporting and acting procedures at their hospitals in cases of child abuse. Conclusion: Although radiologic technologists and radiologists in Saudi Arabia have good knowledge and awareness of child abuse in general, they lack specific knowledge of the reporting and acting procedures at their hospitals in cases of suspected child abuse. National imaging guidelines and training courses are needed to develop appropriate skills in the recognition, imaging and reporting of SPA in infants and young children in Saudi Arabia.

31 January 2026 in European Radiology
Verified
Journal Article
Closed access
PDF file
NANasser M Alzahrani
Nasser M Alzahrani
MPMichael Paddock
Michael Paddock
AJAnnmarie Jeanes
Annmarie Jeanes
ARAlan S. Rigby
Alan S. Rigby
ADAnuradha Dawani
Anuradha Dawani
AOAmaka C. Offiah
Amaka C. Offiah


16 March 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
NANasser M Alzahrani
Nasser M Alzahrani
AAAwad Alzahrani
Awad Alzahrani
ZAZyad M Almutlaq
Zyad M Almutlaq
AAAhmed Alghamdi
Ahmed Alghamdi
YAYazeed Almukhlifi
Yazeed Almukhlifi
JAJaber Hussain Alsalah
Jaber Hussain Alsalah
Objective: To evaluate the performance of photon-counting detector CT (PCD-CT) angiography for the detection and quantification of vascular stenosis. Methods: Web of Science, PubMed, and Cochrane databases were searched from January 1980 to December 2025 to identify studies assessing PCD-CT angiography for the detection and quantification of vascular stenosis, using invasive angiography as the reference standard. The risk of bias of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Diagnostic performance metrics, including sensitivity and specificity and quantification values, were extracted from the included studies and a formal narrative synthesis was performed. The meta-analysis included studies reporting true-positive, false-positive, true-negative, and false-negative data. A meta-analysis was conducted only when a minimum of two eligible studies assessed diagnostic performance within the given vascular territory. Statistical analyses were performed using R software (v4.5.0), applying a random-effects model for the meta-analysis. Results: Of 415 identified studies, 20 were included in the systematic review, comprising a total of 9165 participants, with the majority (17/20, 85%) focusing on coronary artery stenosis. In the meta-analysis of three studies, ultra-high-resolution (UHR) PCD-CT demonstrated excellent diagnostic performance for detecting coronary stenosis for patients with ≥50%, having a pooled sensitivity of 96.1% (95% confidence level (CI): 89.3–99.6), specificity of 87.5% (95% CI: 78.2–93.3), positive predictive value (PPV) of 91.9% (95% CI: 70.3–98.2), and negative predictive value (NPV) of 94.8% (95% CI: 86.0–98.6). Compared with conventional energy-integrating detector CT (EID-CT), PCD-CT consistently showed superior diagnostic performance, particularly in the specificity and PPV. In terms of stenosis quantification, PCD-CT showed closer agreement with reference standards than EID-CT, leading to the reclassification of coronary stenosis severity in up to 49% of patients. Evidence for non-coronary vascular territories, including intracranial and peripheral arteries remains limited but suggests promising diagnostic performance. For lower-limb arterial stenosis, the reported sensitivity was 77.4–91%, and specificity was 72.1–91%. For intracranial in-stent stenosis, PCD-CT demonstrated a sensitivity of 100% and a specificity of 89%. Conclusions: PCD-CT angiography provides high diagnostic performance and improved stenosis quantification for coronary artery stenosis. UHR PCD-CT has excellent diagnostic performance for detecting coronary stenosis and consistently outperforms conventional EID-CT, especially in the specificity and positive predictive value.

23 January 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
FAFahad Mohammed Alraddadi
Fahad Mohammed Alraddadi
HAHassan Aali Almalki
Hassan Aali Almalki
RSRana Mohsen Saklou
Rana Mohsen Saklou
FJFaris Jawad
Faris Jawad
ZAZyad M Almutlaq
Zyad M Almutlaq
NANasser M Alzahrani
Nasser M Alzahrani
Objective: To assess the effectiveness of a fixed contrast injection protocol—75 mL of contrast followed by 40 mL saline at 5 mL/s with an injection duration of 23 s—in achieving diagnostic enhancement in coronary CT angiography (CCTA) using 64-slice detector CT scanner. Materials and Methods: 456 consecutive patients with suspected coronary disease who underwent CCTA on a 64-slice detector CT scanner between January 2023 and December 2024 and were retrospectively enrolled. Each patient received 75 mL of contrast medium followed by 40 mL of saline at a flow rate of 5 mL/s, with a total injection duration of 23 s. Two radiologists, blinded to patient information, independently measured the contrast enhancement (HU) values in the coronary segments, ascending and descending aorta, and left ventricle. Attenuation levels ≥250 HU were considered diagnostic. Patients were grouped by body weight into two categories: Group 1 (≤75 kg) and Group 2 (>75 kg). The independent t-test and Mann–Whitney U test were used to compare HU values in each vessel between the two groups, while the Chi-square test was applied to compare enhancement success rates (HU ≥ 250) between the groups per vessel. Results: A total of 281 patients (mean age: 51.88 years ± 11.15 [SD]; 167 male, 114 female), were included. Statistically significant differences in the HU enhancement measurements were found between groups (p < 0.001–0.007). However, all segments showed mean and median HU values above 250 HU. Enhancement success rates were significantly higher in Group 1 (p = 0.005–0.04), except in the ascending aorta, descending aorta, left main coronary artery, middle right coronary, distal right coronary artery, and middle left circumflex artery, where the rates were statistically comparable between the groups (p = 0.054–0.61). Conclusions: A fixed contrast protocol (75 mL of contrast medium followed by 40 mL of saline at a 5 mL/s flow rate with a total injection duration of 23 s) appears to be feasible for achieving diagnostic contrast enhancement in CCTA using a 64-slice multidetector CT scanner. This protocol may offer a simplified alternative to individualized, weight-based contrast dosing strategies.