Ahmed Alghamdi

Dr. Ahmed Alghamdi


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2023 in Skeletal Radiology
Verified
Journal Article
Open access
PDF file
AAAhmed Alghamdi
Ahmed Alghamdi
SMSanjeev Madan
Sanjeev Madan
FSFarag Shuweihdi
Farag Shuweihdi
AOAmaka C. Offiah
Amaka C. Offiah
Objectives: To determine the accuracy of the EOS imaging system compared to the gold standard computed tomography (CT) scan, for the measurement of native and postoperative/prosthetic hip parameters in adolescents and adults. Methods: Medline, Cochrane Systematic Review, and Web of Science databases were searched to obtain relevant articles published between January 1964 and February 2021. All articles published in English. Inclusion and exclusion criteria were developed according to the Population, Intervention, Comparator, Outcome (PICO) framework. Three reviewers independently assessed the quality of included studies using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist. A narrative synthesis of the articles and a meta-analysis were conducted. The heterogeneity exhibited by the effect sizes was obtained using a forest plot, the Q statistic and the I2 index. Reliability coefficients were transformed into Fisher’s Z to normalise their distribution and stabilise the variances. For each meta-analysis, an effect size (average reliability coefficient) and a 95% confidence interval were calculated and presented in a forest plot. The amount of radiation dose between modalities was compared. Results: The search retrieved 75 articles, six of which met inclusion and exclusion criteria. The meta-analysis included five of these six studies (sample size from 20 to 90). Comparing EOS and CT, the estimated average correlation (effect size) for combined studies was significantly high (r = 0.84, 95% CI = 0.78 to 0.88, p-value < 0.001). With respect to Pearson’s correlation between EOS and CT, the estimated average correlation for combined studies was significantly high (r = 0.86, 95% CI = 0.80 to 0.90, p-value < 0.001). Average radiation dose for EOS was 0.18 ± 0.05 mGy for the anteroposterior view (AP) and 0.45 ± 0.08 mGy for the lateral view; and for CT was 8.4 to 15.6 mGy. Conclusion: The EOS imaging system has a high correlation with CT for preoperative and postoperative/prosthetic hip measurements, with considerably lower irradiation of patients.

16 March 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
NANasser M Alzahrani
Nasser M Alzahrani
AAAwad Alzahrani
Awad Alzahrani
ZAZyad M Almutlaq
Zyad M Almutlaq
AAAhmed Alghamdi
Ahmed Alghamdi
YAYazeed Almukhlifi
Yazeed Almukhlifi
JAJaber Hussain Alsalah
Jaber Hussain Alsalah
Objective: To evaluate the performance of photon-counting detector CT (PCD-CT) angiography for the detection and quantification of vascular stenosis. Methods: Web of Science, PubMed, and Cochrane databases were searched from January 1980 to December 2025 to identify studies assessing PCD-CT angiography for the detection and quantification of vascular stenosis, using invasive angiography as the reference standard. The risk of bias of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Diagnostic performance metrics, including sensitivity and specificity and quantification values, were extracted from the included studies and a formal narrative synthesis was performed. The meta-analysis included studies reporting true-positive, false-positive, true-negative, and false-negative data. A meta-analysis was conducted only when a minimum of two eligible studies assessed diagnostic performance within the given vascular territory. Statistical analyses were performed using R software (v4.5.0), applying a random-effects model for the meta-analysis. Results: Of 415 identified studies, 20 were included in the systematic review, comprising a total of 9165 participants, with the majority (17/20, 85%) focusing on coronary artery stenosis. In the meta-analysis of three studies, ultra-high-resolution (UHR) PCD-CT demonstrated excellent diagnostic performance for detecting coronary stenosis for patients with ≥50%, having a pooled sensitivity of 96.1% (95% confidence level (CI): 89.3–99.6), specificity of 87.5% (95% CI: 78.2–93.3), positive predictive value (PPV) of 91.9% (95% CI: 70.3–98.2), and negative predictive value (NPV) of 94.8% (95% CI: 86.0–98.6). Compared with conventional energy-integrating detector CT (EID-CT), PCD-CT consistently showed superior diagnostic performance, particularly in the specificity and PPV. In terms of stenosis quantification, PCD-CT showed closer agreement with reference standards than EID-CT, leading to the reclassification of coronary stenosis severity in up to 49% of patients. Evidence for non-coronary vascular territories, including intracranial and peripheral arteries remains limited but suggests promising diagnostic performance. For lower-limb arterial stenosis, the reported sensitivity was 77.4–91%, and specificity was 72.1–91%. For intracranial in-stent stenosis, PCD-CT demonstrated a sensitivity of 100% and a specificity of 89%. Conclusions: PCD-CT angiography provides high diagnostic performance and improved stenosis quantification for coronary artery stenosis. UHR PCD-CT has excellent diagnostic performance for detecting coronary stenosis and consistently outperforms conventional EID-CT, especially in the specificity and positive predictive value.

13 June 2026 in Skeletal Radiology
Verified
Journal Article
Open access
PDF file
AAAhmed Alghamdi
Ahmed Alghamdi
NLNatalie Lee
Natalie Lee
FSFARAG SHUWEIHDI
FARAG SHUWEIHDI
AOAmaka C. Offiah
Amaka C. Offiah
Objective: To compare mechanical axis image quality between the EOS imaging system and digital radiograph (DR). Materials and methods: This retrospective study included 100 patients who underwent both EOS and DR mechanical axis imaging. It was conducted according to the Quality and Standards Department at the University of Sheffield. Three observers independently scored the DR and EOS images according to the modified European guidelines on quality criteria for diagnostic radiographic images in paediatrics: resolution, coverage of the area of interest, positioning, contrast, and motion. The range of scores was (Yes) for the fulfilled criterion and (No) for the not fulfilled criterion. For the motion criterion, the scores were (No) if the image quality criterion was not fulfilled (motion) and (Yes) if the image quality criterion was fulfilled (no motion). Inter-rater agreement was measured using the Gwet’s agreement coefficient (AC1) with a 95% confidence interval. The accuracy of the EOS was assessed using sensitivity, specificity, and the area under curve (AUC). Variables between the EOS and DR were compared using McNemar’s test. Both Gwet’s AC1 and corresponding 95%CI were computed using irrCAC library in R4.41 software. Results: The mean (range) age of patients when they underwent DR and EOS imaging was 11.2 (4–18) and 11.8 (5–17) years, respectively. EOS demonstrated almost perfect inter-rater reliability in the resolution criterion (AC1 = 0.99, 95% CI = 0.98,1.00, p < 0.001), while DR showed similar reliability in the motion artefacts (AC1 = 0.96, 95% CI = 0.92.00, p < 0.001). Intra-rater reliability was high for most criteria. EOS images demonstrated high sensitivity for all criteria and variable specificity, which equalled or exceeded that of DR images. Significant differences were found in some criteria, such as the coverage of the area of interest (chi-squared = 37.39, p < 0.001) and hip level (chi-squared statistic = 31.44, p < 0.001). Conclusion: The high AC1, sensitivity, and AUCs highlight the diagnostic image quality of the EOS imaging system for mechanical axis images, making it a valuable modality in clinical settings. Therefore, the EOS imaging system can be used instead of DR in this context, offering advantages such as lower irradiation, shorter scanning time, and the capability for 3D reconstruction.