GammaTile cesium-131 (131Cs) permanent brain implant has received Food and Drug Administration (FDA) clearance as a promising treatment for certain brain tumors. Our center was the first institution in the United States after FDA clearance to offer the clinical use of GammaTile brachytherapy outside of a clinical trial. The purpose of this work is to aid the medical physicist and radiation oncologist in implementing this collagen carrier tile brachytherapy (CTBT) program in their practice. A total of 23 patients have been treated with GammaTile to date at our center. Treatment planning system (TPS) commissioning was performed by configuring the parameters for the 131Cs (IsoRay Model CS-1, Rev2) source, and doses were validated with the consensus data from the American Association of Physicists in Medicine TG-43U1S2. Implant procedures, dosimetry, postimplant planning, and target delineations were established based on our clinical experience. Radiation safety aspects were evaluated based on exposure rate measurements of implanted patients, as well as body and ring badge measurements. An estimated timeframe of the GammaTile clinical responsibilities for the medical physicist, radiation oncologist, and neurosurgeon is presented. TPS doses were validated with published dose to water for 131Cs. Clinical aspects, including estimation of the number of tiles, treatment planning, dosimetry, and radiation safety considerations, are presented. The implementation of the GammaTile program requires collaboration from multiple specialties, including medical physics, radiation oncology, and neurosurgery. This manuscript provides a roadmap for the implementation of this therapy.
3D printing technology has allowed the creation of custom applicators for high dose rate (HDR) brachytherapy, especially for complex anatomy. With conformal therapy comes the need for advanced dosimetric verification. It is important to demonstrate how dose to 3D printed materials can be related to dose to water. This study aimed to determine dose differences and uncertainties using 3D printed PLA and ABS plastics for Radiochromic film calibration in HDR brachytherapy. Gafchromic EBT3 film pieces were irradiated in water with an Ir-192 source at calculated dose levels ranging from 0 to 800 cGy, to create the control calibration curve. Similarly, film was placed below 3D printed PLA and ABS blocks and irradiated at the same dose levels calculated for water, ranging from 0 to 800 cGy. After a 72-h development time, film pieces were scanned on a flatbed scanner and the median pixel value was recorded in the region of highest dose. This value was converted to net optical density (NOD). A rational function was used to fit a calibration curve in water that relates NOD to dose for red, green, and blue color channels. Based on this fitted curve, ABS and PLA NOD values were used to estimate dose in 3D printed plastics. From the fitted calibration curve, mean residual error between measured and planned dose to water was less than 1% for each color channel at high dose levels. At high dose levels, ABS and PLA mean residual errors were about 6.9 and 7.8% in the red channel, while 5.2 and 5.7% in the green channel. Combined uncertainties measured to be about 6.9% at high dose levels. This study demonstrated dose differences and uncertainties using 3D printed applicators for HDR Ir-192 brachytherapy.
Glioblastoma recurrence between initial resection and standard-of-care adjuvant chemoradiotherapy (CRT) is a negative prognostic factor in an already highly aggressive disease. Re-resection with GammaTileⓇ(GT Medical Technologies Inc., Tempe, AZ) placement affords expedited adjuvant radiation to mitigate the likelihood of such growth. Here, we report a glioblastoma patient who underwent re-resection and GammaTileⓇ (GT) placement within two months of the initial gross total resection due to regrowth that reached the size of the original presenting tumor. The patient subsequently received concurrent temozolomide and 60 Gy external beam to regions outside of the brachytherapy range, fulfilling the generally accepted Stupp regimen. The patient tolerated the treatment without complication. The dosimetrics and implications of the case presentation are reviewed.