3D printing technology has allowed the creation of custom applicators for high dose rate (HDR) brachytherapy, especially for complex anatomy. With conformal therapy comes the need for advanced dosimetric verification. It is important to demonstrate how dose to 3D printed materials can be related to dose to water. This study aimed to determine dose differences and uncertainties using 3D printed PLA and ABS plastics for Radiochromic film calibration in HDR brachytherapy. Gafchromic EBT3 film pieces were irradiated in water with an Ir-192 source at calculated dose levels ranging from 0 to 800 cGy, to create the control calibration curve. Similarly, film was placed below 3D printed PLA and ABS blocks and irradiated at the same dose levels calculated for water, ranging from 0 to 800 cGy. After a 72-h development time, film pieces were scanned on a flatbed scanner and the median pixel value was recorded in the region of highest dose. This value was converted to net optical density (NOD). A rational function was used to fit a calibration curve in water that relates NOD to dose for red, green, and blue color channels. Based on this fitted curve, ABS and PLA NOD values were used to estimate dose in 3D printed plastics. From the fitted calibration curve, mean residual error between measured and planned dose to water was less than 1% for each color channel at high dose levels. At high dose levels, ABS and PLA mean residual errors were about 6.9 and 7.8% in the red channel, while 5.2 and 5.7% in the green channel. Combined uncertainties measured to be about 6.9% at high dose levels. This study demonstrated dose differences and uncertainties using 3D printed applicators for HDR Ir-192 brachytherapy.
Hazardous work zones (i.e., hot, warm, and cold) are typically established by emergency response teams during hazardous materials (HAZMAT) calls but less consistently for fire responses to segment personnel and response activities in the immediate geographic area around the fire. Despite national guidelines, studies have documented the inconsistent use of respiratory protective equipment by firefighters at the fire scene. In this case-series report, we describe warm zone gas levels using multigas detectors across five independent fire incident responses all occurring in a large South Florida fire department. Multigas detector data collected at each fire response indicate the presence of sustained levels of volatile organic compounds in the "warm zone" of each fire event. These cases suggest that firefighters should not only implement strategies for multigas detector use within the warm zone but also include respiratory protection to provide adequate safety from toxic exposures in the warm zone.
Glioblastoma recurrence between initial resection and standard-of-care adjuvant chemoradiotherapy (CRT) is a negative prognostic factor in an already highly aggressive disease. Re-resection with GammaTileⓇ(GT Medical Technologies Inc., Tempe, AZ) placement affords expedited adjuvant radiation to mitigate the likelihood of such growth. Here, we report a glioblastoma patient who underwent re-resection and GammaTileⓇ (GT) placement within two months of the initial gross total resection due to regrowth that reached the size of the original presenting tumor. The patient subsequently received concurrent temozolomide and 60 Gy external beam to regions outside of the brachytherapy range, fulfilling the generally accepted Stupp regimen. The patient tolerated the treatment without complication. The dosimetrics and implications of the case presentation are reviewed.
Purpose. We propose a linear network-based optimization model (LNBM) for high dose rate brachytherapy (HDR-BT) that uses a novel distance metric to measure the discrepancy between the dose delivered and the prescription. Unlike models in the literature, LNBM takes advantage of the adjacency structure of the patients’ voxels by formalizing them into a network. Methods. We apply LNBM to a set of 7 cervical cancer cases treated with HDR-BT. State-of-the-art commercial optimization software solves LNBM to global optimality. The results of LNBM are compared with those of inverse planning by simulated annealing (IPSA) based on tumor coverage, dosimetric indices for the critical organs at risk (OARs), isodose contour plots, and two metrics of homogeneity new to this work (hot-spots volumes and diameters). Results. LNBM produces plans with improved tumor coverage and with improved isodose contour plots and dosimetric indices for OARs that receive highest dose (bladder and rectum in this study) when compared with IPSA. Using new metrics of homogeneity, we also demonstrate that LNBM produces more homogeneous plans on these cases. An analysis of the solutions of LNBM shows that they use a significant part of the voxel network structure, providing evidence that the plans produced are different from those created using traditional penalty approaches and are more directly guided by the geometry of the patients’ anatomy. Conclusions. The proposed linear network-based optimization model efficiently generates more homogeneous high quality treatment plans for HDR-BT.