This study investigated the effects of dietary linolenic acid (C18:3n-3) v. linoleic acid (C18:2n-6) on fatty acid composition and protein expression of key lipogenic enzymes, acetyl-CoA carboxylase (ACC), stearoyl-CoA desaturase (SCD) and delta 6 desaturase (6d expression in muscle. There was no significant effect of the diet on ACC protein expression. Inhibition of the 6d proteins was found to be relatively higher in subcutaneous adipose tissue when compared with longissimus muscle. It is suggested that dietary manipulation of fatty acid composition in ruminants is mediated, at least partially, through the regulation of lipogenic enzymes expression and that regulation of the bovine lipogenic enzymes expression is tissue specific.
In this study, liposomes enclosing eugenol were prepared using microfluidics. Two lipids—1,2-dimyristoyl-sn-glycero-3-phosphocholine, 18:0 (DSPC) and 2-dimyristoyl-sn-glycero-3-phosphocholine, 14:0 (DMPC)—and microfluidic chips with serpentine and Y-shaped micromixing designs were used for the liposomal formulation. Minimum bactericidal concentration (MBC) values indicated that eugenol was more effective against Gram-negative than Gram-positive bacteria. Four different flow-rate ratios (FRR 2:1, 3:1, 4:1, 5:1) were explored. All liposomes’ encapsulation efficiency (EE) was determined: 94.34% for DSPC 3:1 and 78.63% for DMPC 5:1. The highest eugenol release of 99.86% was observed at pH 4, DMPC 3:1 (Y-shaped chip). Liposomes were physically stable at 4, 20 and 37 °C for 60 days as determined by their size, polydispersity index (PDI) and zeta potential (ZP). The most stable liposomes were observed at FRR 5:1 for DSPC. EE, stability, and eugenol release studies proved that the liposomal formulations produced can be used as delivery vehicles to increase food safety.
An electrocatalytic screen-printed sensor has been investigated for the measurement of the biologically important biomolecule vitamin B1 (thiamine) for the first time in food supplements. Under basic conditions, the vitamin was converted to its electrochemically active thiolate anion species. It was shown that an electrocatalytic oxidation reaction occurred with the screen-printed carbon electrode containing the mediator cobalt phthalocyanine (CoPC-SPCE). This had the advantage of producing an analytical response current at an operating potential of 0 V vs. Ag/AgCl compared to +0.34 V obtained with plain SPCEs. This resulted in improved selectivity and limit of detection. Detailed studies on the underlying mechanism occurring with the sensor are reported in this paper. A linear response was obtained between 0.1 and 20 µg mL−1, which was suitable for the quantification of the vitamin in two commercial products containing vitamin B1. The mean recovery for a multivitamin tablet with a declared content of 5 mg was 101% (coefficient of variation (CV) of 9.6%). A multivitamin drink, which had a much lower concentration of vitamin B1 (0.22 mg/100 mL), gave a mean recovery of 93.3% (CV 7.2%). These results indicate that our sensor holds promise for quality control of food supplements and other food types.