Jae-Jun Kim

Dr. Jae-Jun Kim

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2020 in Reports on Progress in Physics
Verified
Journal Article
Closed access
PDF file
JKJae-Jun Kim
Jae-Jun Kim
HLHewei Liu
Hewei Liu
AAAlireza Ousati Ashtiani
Alireza Ousati Ashtiani
HJHongrui Jiang
Hongrui Jiang
Natural visual systems have inspired scientists and engineers to mimic their intriguing features for the development of advanced photonic devices that can provide better solutions than conventional ones. Among various kinds of natural eyes, researchers have had intensive interest in mammal eyes and compound eyes due to their advantages in optical properties such as focal length tunability, high-resolution imaging, light intensity modulation, wide field of view, high light sensitivity, and efficient light management. A variety of different approaches in the broad field of science and technology have been tried and succeeded to duplicate the functions of natural eyes and develop bioinspired photonic devices for various applications. In this review, we present a comprehensive overview of bioinspired artificial eyes and photonic devices that mimic functions of natural eyes. After we briefly introduce visual systems in nature, we discuss optical components inspired by the mammal eyes, including tunable lenses actuated with different mechanisms, curved image sensors with low aberration, and light intensity modulators. Next, compound eye inspired photonic devices are presented, such as microlenses and micromirror arrays, imaging sensor arrays on curved surfaces, self-written waveguides with microlens arrays, and antireflective nanostructures (ARS). Subsequently, compound eyes with focal length tunability, photosensitivity enhancers, and polarization imaging sensors are described.

25 August 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
JKJae-Jun Kim
Jae-Jun Kim
AWAlex Watras
Alex Watras
HLHewei Liu
Hewei Liu
ZZZhanpeng Zeng
Zhanpeng Zeng
JGJacob A. Greenberg
Jacob A. Greenberg
HJHongrui Jiang
Hongrui Jiang
The quality and the extent of intra-abdominal visualization are critical to a laparoscopic procedure. Currently, a single laparoscope is inserted into one of the laparoscopic ports to provide intra-abdominal visualization. The extent of this field of view (FoV) is rather restricted and may limit efficiency and the range of operations. Here we report a trocar-camera assembly (TCA) that promises a large FoV, and improved efficiency and range of operations. A video stitching program processes video data from multiple miniature cameras and combines these videos in real-time. This stitched video is then displayed on an operating monitor with a much larger FoV than that of a single camera. In addition, we successfully performed a standard and a modified bean drop task, without any distortion, in a simulator box by using the TCA and taking advantage of its FoV which is larger than that of the current laparoscopic cameras. We successfully demonstrated its improved efficiency and range of operations. The TCA frees up a surgical port and potentially eliminates the need of physical maneuvering of the laparoscopic camera, operated by an assistant.

3 May 2024 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
PDF file
EHElias A. Halabi
Elias A. Halabi
IGIsabel Gessner
Isabel Gessner
KYKatherine S. Yang
Katherine S. Yang
JKJae-Jun Kim
Jae-Jun Kim
RJRupsa Jana
Rupsa Jana
RWRalph Weissleder
Ralph Weissleder
Multiplexed bead assays for solution‐phase biosensing often encounter cross‐over reactions during signal amplification steps, leading to unwanted false positive and high background signals. Current solutions involve complex custom‐designed and costly equipment, limiting their application in simple laboratory setup. In this study, we introduce a straightforward protocol to adapt a multiplexed single‐bead assay to standard fluorescence imaging plates, enabling the simultaneous analysis of thousands of reactions per plate. This approach focuses on the design and synthesis of bright fluorescent and magnetic microspheres (MagSiGlow) with multiple fluorescent wavelengths serving as unique detection markers. The imaging‐based, single‐bead assay, combined with a scripted algorithm, allows the detection, segmentation, and co‐localization on average of 7500 microspheres per field of view across five imaging channels in less than one second. We demonstrate the effectiveness of this method with remarkable sensitivity at low protein detection limits (100 pg/mL). This technique showed over 85 % reduction in signal cross‐over to the solution‐based method after the concurrent detection of tumor‐associated protein biomarkers. This approach holds the promise of substantially enhancing high throughput biosensing for multiple targets, seamlessly integrating with rapid image analysis algorithms.

14 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
AWAlex Watras
Alex Watras
JKJae-Jun Kim
Jae-Jun Kim
HLHewei Liu
Hewei Liu
YU HEN HUYU HEN HU
YU HEN HU
HJHongrui Jiang
Hongrui Jiang
An optimal camera placement problem is investigated. The objective is to maximize the area of the field of view (FoV) of a stitched video obtained by stitching video streams from an array of cameras. The positions and poses of these cameras are restricted to a given set of selections. The camera array is designed to be placed inside the abdomen to support minimally invasive laparoscopic surgery. Hence, a few non-traditional requirements/constraints are imposed: Adjacent views are required to overlap to support image registration for seamless video stitching. The resulting effective FoV should be a contiguous region without any holes and should be a convex polygon. With these requirements, traditional camera placement algorithms cannot be directly applied to solve this problem. In this work, we show the complexity of this problem grows exponentially as a function of the problem size, and then present a greedy polynomial time heuristic solution that approximates well to the globally optimal solution. We present a new approach to directly evaluate the combined coverage area (area of FoV) as the union of a set of quadrilaterals. We also propose a graph-based approach to ensure the stitching requirement (overlap between adjacent views) is satisfied. We present a method to find a convex polygon with maximum area from a given polygon. Several design examples show that the proposed algorithm can achieve larger FoV area while using much less computing time.

11 July 2024 in Sensors & Diagnostics
Verified
Journal Article
Open access
PDF file
JKJae-Jun Kim
Jae-Jun Kim
JHJae-Sang Hong
Jae-Sang Hong
HKHyunho Kim
Hyunho Kim
MCMoonhyun Choi
Moonhyun Choi
UWUrsula Winter
Ursula Winter
Hyungsoon ImHyungsoon Im
Hyungsoon Im
CRISPR/Cas13a-based rapid amplification-free miRNA detection using a portable dark-field imaging system in 30 min.

10 May 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
AWAlex Watras
Alex Watras
JKJae-Jun Kim
Jae-Jun Kim
JKJianwei Ke
Jianwei Ke
HLHewei Liu
Hewei Liu
JGJacob A. Greenberg
Jacob A. Greenberg
HJHongrui Jiang
Hongrui Jiang
Existing laparoscopic surgery systems use a single laparoscope to visualize the surgical area with a limited field of view (FoV), necessitating maneuvering the laparoscope to search a target region. In some cases, the laparoscope needs to be moved from one surgical port to another one to detect target organs. These maneuvers would cause longer surgical time and degrade the efficiency of operation. We hypothesize that if an array of cameras can be deployed to provide a stitched video with an expanded FoV and small blind spots, the time required to perform multiple tasks at different sites can be significantly reduced. We developed a micro-camera array that can enlarge the FoV and reduce blind spots between the cameras by optimizing the angle of cameras. The video stream of this micro-camera array was designed to be processed in real-time to provide a stitched video with the expanded FoV. We mounted this micro-camera array to a Fundamentals of Laparoscopic Surgery (FLS) laparoscopic trainer box and designed an experiment to validate the hypothesis above. Surgeons, residents, and a medical student were recruited to perform a modified bean drop task, and the completion time was compared against that measured using a traditional single-camera laparoscope. It was observed that utilizing the micro-camera array, the completion time of the modified bean drop task was 203 ± 55 s while using the laparoscope, the completion time was 245 ± 114 s, with a p-value of 0.00097. It is also observed that the benefit of using an FoV-expanded camera array does not diminish for subjects who are more experienced. This test provides convincing evidence and validates the hypothesis that expanded FoV with small blind spots can reduce the operation time for laparoscopic surgical tasks.