Hewei Liu

Hewei Liu

Auto-generated profile, based on publicly available information

Hewei Liu

Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2016 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
HLHewei Liu
Hewei Liu
YHYinggang Huang
Yinggang Huang
HJHongrui Jiang
Hongrui Jiang
Significance: Although biological eyes ingeniously adopt diverse optical approaches to improve their scotopic vision, enhancement of the photosensitivity in artificial imaging systems still clings to electronic methods. Here we present an all-optical strategy to significantly improve the low-light imaging capability of manmade sensors, which is inspired by the optical concept of superposition eyes and elephantnose fish eye. Besides showing an artificial eye whose scotopic vision is largely improved by a bioinspired photosensitivity enhancer, we also demonstrate a complete solution to acquire high-resolution images under low-light conditions with our device. More importantly, our purely optical approach can be used on top of other electronic technologies, which can boost the most state-of-the-art imaging sensor whose photosensitivity is gaining on the physical limitations.

16 March 2020 in Reports on Progress in Physics
Verified
Journal Article
Closed access
PDF file
JKJae-Jun Kim
Jae-Jun Kim
HLHewei Liu
Hewei Liu
AAAlireza Ousati Ashtiani
Alireza Ousati Ashtiani
HJHongrui Jiang
Hongrui Jiang
Natural visual systems have inspired scientists and engineers to mimic their intriguing features for the development of advanced photonic devices that can provide better solutions than conventional ones. Among various kinds of natural eyes, researchers have had intensive interest in mammal eyes and compound eyes due to their advantages in optical properties such as focal length tunability, high-resolution imaging, light intensity modulation, wide field of view, high light sensitivity, and efficient light management. A variety of different approaches in the broad field of science and technology have been tried and succeeded to duplicate the functions of natural eyes and develop bioinspired photonic devices for various applications. In this review, we present a comprehensive overview of bioinspired artificial eyes and photonic devices that mimic functions of natural eyes. After we briefly introduce visual systems in nature, we discuss optical components inspired by the mammal eyes, including tunable lenses actuated with different mechanisms, curved image sensors with low aberration, and light intensity modulators. Next, compound eye inspired photonic devices are presented, such as microlenses and micromirror arrays, imaging sensor arrays on curved surfaces, self-written waveguides with microlens arrays, and antireflective nanostructures (ARS). Subsequently, compound eyes with focal length tunability, photosensitivity enhancers, and polarization imaging sensors are described.

25 August 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
JKJae-Jun Kim
Jae-Jun Kim
AWAlex Watras
Alex Watras
HLHewei Liu
Hewei Liu
ZZZhanpeng Zeng
Zhanpeng Zeng
JGJacob A. Greenberg
Jacob A. Greenberg
HJHongrui Jiang
Hongrui Jiang
The quality and the extent of intra-abdominal visualization are critical to a laparoscopic procedure. Currently, a single laparoscope is inserted into one of the laparoscopic ports to provide intra-abdominal visualization. The extent of this field of view (FoV) is rather restricted and may limit efficiency and the range of operations. Here we report a trocar-camera assembly (TCA) that promises a large FoV, and improved efficiency and range of operations. A video stitching program processes video data from multiple miniature cameras and combines these videos in real-time. This stitched video is then displayed on an operating monitor with a much larger FoV than that of a single camera. In addition, we successfully performed a standard and a modified bean drop task, without any distortion, in a simulator box by using the TCA and taking advantage of its FoV which is larger than that of the current laparoscopic cameras. We successfully demonstrated its improved efficiency and range of operations. The TCA frees up a surgical port and potentially eliminates the need of physical maneuvering of the laparoscopic camera, operated by an assistant.

14 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
AWAlex Watras
Alex Watras
JKJae-Jun Kim
Jae-Jun Kim
HLHewei Liu
Hewei Liu
YU HEN HUYU HEN HU
YU HEN HU
HJHongrui Jiang
Hongrui Jiang
An optimal camera placement problem is investigated. The objective is to maximize the area of the field of view (FoV) of a stitched video obtained by stitching video streams from an array of cameras. The positions and poses of these cameras are restricted to a given set of selections. The camera array is designed to be placed inside the abdomen to support minimally invasive laparoscopic surgery. Hence, a few non-traditional requirements/constraints are imposed: Adjacent views are required to overlap to support image registration for seamless video stitching. The resulting effective FoV should be a contiguous region without any holes and should be a convex polygon. With these requirements, traditional camera placement algorithms cannot be directly applied to solve this problem. In this work, we show the complexity of this problem grows exponentially as a function of the problem size, and then present a greedy polynomial time heuristic solution that approximates well to the globally optimal solution. We present a new approach to directly evaluate the combined coverage area (area of FoV) as the union of a set of quadrilaterals. We also propose a graph-based approach to ensure the stitching requirement (overlap between adjacent views) is satisfied. We present a method to find a convex polygon with maximum area from a given polygon. Several design examples show that the proposed algorithm can achieve larger FoV area while using much less computing time.

10 May 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
AWAlex Watras
Alex Watras
JKJae-Jun Kim
Jae-Jun Kim
JKJianwei Ke
Jianwei Ke
HLHewei Liu
Hewei Liu
JGJacob A. Greenberg
Jacob A. Greenberg
HJHongrui Jiang
Hongrui Jiang
Existing laparoscopic surgery systems use a single laparoscope to visualize the surgical area with a limited field of view (FoV), necessitating maneuvering the laparoscope to search a target region. In some cases, the laparoscope needs to be moved from one surgical port to another one to detect target organs. These maneuvers would cause longer surgical time and degrade the efficiency of operation. We hypothesize that if an array of cameras can be deployed to provide a stitched video with an expanded FoV and small blind spots, the time required to perform multiple tasks at different sites can be significantly reduced. We developed a micro-camera array that can enlarge the FoV and reduce blind spots between the cameras by optimizing the angle of cameras. The video stream of this micro-camera array was designed to be processed in real-time to provide a stitched video with the expanded FoV. We mounted this micro-camera array to a Fundamentals of Laparoscopic Surgery (FLS) laparoscopic trainer box and designed an experiment to validate the hypothesis above. Surgeons, residents, and a medical student were recruited to perform a modified bean drop task, and the completion time was compared against that measured using a traditional single-camera laparoscope. It was observed that utilizing the micro-camera array, the completion time of the modified bean drop task was 203 ± 55 s while using the laparoscope, the completion time was 245 ± 114 s, with a p-value of 0.00097. It is also observed that the benefit of using an FoV-expanded camera array does not diminish for subjects who are more experienced. This test provides convincing evidence and validates the hypothesis that expanded FoV with small blind spots can reduce the operation time for laparoscopic surgical tasks.

27 January 2022 in Journal of Signal Processing Systems
Verified
Journal Article
Closed access
PDF file
JKJianwei Ke
Jianwei Ke
AWAlex Watras
Alex Watras
JKJae-Jun Kim
Jae-Jun Kim
HLHewei Liu
Hewei Liu
HJHongrui Jiang
Hongrui Jiang
YU HEN HUYU HEN HU
YU HEN HU