Chunlong Fei

Prof. Dr. Chunlong Fei

School of Microelectronics, Xidian University, Xi’an 710071, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2016 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Chunlong FeiChunlong Fei
Chunlong Fei
CCChi Tat Chiu
Chi Tat Chiu
XCXiaoyang Chen
Xiaoyang Chen
ZCZeyu Chen
Zeyu Chen
JMJianguo Ma
Jianguo Ma
Qifa ZhouQifa Zhou
Qifa Zhou
High resolution ultrasonic imaging requires high frequency wide band ultrasonic transducers, which produce short pulses and highly focused beam. However, currently the frequency of ultrasonic transducers is limited to below 100 MHz, mainly because of the challenge in precise control of fabrication parameters. This paper reports the design, fabrication and characterization of sensitive broadband lithium niobate (LiNbO3) single element ultrasonic transducers in the range of 100–300 MHz, as well as their applications in high resolution imaging. All transducers were built for an f-number close to 1.0, which was achieved by press-focusing the piezoelectric layer into a spherical curvature. Characterization results demonstrated their high sensitivity and a −6 dB bandwidth greater than 40%. Resolutions better than 6.4 μm in the lateral direction and 6.2 μm in the axial direction were achieved by scanning a 4 μm tungsten wire target. Ultrasonic biomicroscopy images of zebrafish eyes were obtained with these transducers which demonstrate the feasibility of high resolution imaging with a performance comparable to optical resolution.

18 January 2022 in Frontiers in Materials
Verified
Journal Article
Open access
JCJun Chen
Jun Chen
Chunlong FeiChunlong Fei
Chunlong Fei
DLDanmei Lin
Danmei Lin
PGPengkai Gao
Pengkai Gao
JZJunshan Zhang
Junshan Zhang
YYYinTang Yang
YinTang Yang
The ultrahigh-frequency (UHF) ultrasonic transducers are active in various fields, including nondestructive evaluation in the semiconductor industry, microscopic biological organization imaging in biomedicine, particle manipulation, and so on. In these fields ultrahigh-frequency (UHF) ultrasonic transducers play a critical role in the performance of related equipment. This article will focus on the topic of ultrahigh-frequency ultrasonic transducers’ preparation, and reviews three aspects: material selection, focus design, and acoustic energy transmission matching. Provides a summary of the current research status, and puts forward some views on the future development of UHF ultrasound devices.

18 December 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Chunlong FeiChunlong Fei
Chunlong Fei
YYYaoheng Yang
Yaoheng Yang
FGFeifei Guo
Feifei Guo
PLPengfei Lin
Pengfei Lin
QCQiang Chen
Qiang Chen
LSLei Sun
Lei Sun
As the key component of intravascular ultrasound (IVUS) imaging systems, traditional commercial side-looking IVUS transducers are flat and unfocused, which limits their lateral resolution. We propose a PMN-PT single crystal IVUS transducer with a half-concave geometry. This unique configuration makes it possible to conduct geometric focusing at a desired depth. To compare performances, the proposed and the traditional flat transducer with similar dimensions were fabricated. We determined that the half-concave transducer has a slightly higher center frequency (35 MHz), significantly broader -6 dB bandwidth (54%) but a higher insertion loss (-22.4 dB) compared to the flat transducer (32 MHz, 28%, and -19.3 dB, respectively). A significant enhancement of the lateral resolution was also confirmed. The experimental results are in agreement with the finite element simulation results. This preliminary investigation suggests that the half-concave geometry design is a promising approach in the development of focused IVUS transducers with broad bandwidth and high lateral resolution.

11 January 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
Dongdong ChenDongdong Chen
Dongdong Chen
XCXinhui Cui
Xinhui Cui
QZQidong Zhang
Qidong Zhang
DI LIDI LI
DI LI
WCWenyang Cheng
Wenyang Cheng
Yintang YangYintang Yang
Yintang Yang
As traditional ultrasonic imaging systems (UIS) are expensive, bulky, and power-consuming, miniaturized and portable UIS have been developed and widely utilized in the biomedical field. The performance of integrated circuits (ICs) in portable UIS obviously affects the effectiveness and quality of ultrasonic imaging. In the ICs for UIS, the analog-to-digital converter (ADC) is used to complete the conversion of the analog echo signal received by the analog front end into digital for further processing by a digital signal processing (DSP) or microcontroller unit (MCU). The accuracy and speed of the ADC determine the precision and efficiency of UIS. Therefore, it is necessary to systematically review and summarize the characteristics of different types of ADCs for UIS, which can provide valuable guidance to design and fabricate high-performance ADC for miniaturized high resolution UIS. In this paper, the architecture and performance of ADC for UIS, including successive approximation register (SAR) ADC, sigma-delta (Σ-∆) ADC, pipelined ADC, and hybrid ADC, have been systematically introduced. In addition, comparisons and discussions of different types of ADCs are presented. Finally, this paper is summarized, and presents the challenges and prospects of ADC ICs for miniaturized high resolution UIS.

21 July 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Chenxue HouChenxue Hou
Chenxue Hou
Chunlong FeiChunlong Fei
Chunlong Fei
ZLZhaoxi Li
Zhaoxi Li
SZShuxiao Zhang
Shuxiao Zhang
JMJiujing Man
Jiujing Man
Wei FengWei Feng
Wei Feng
Ultrasonic transducers with broad bandwidth are considered to have high axial resolution and good ultrasound scanning flexibility for the clinical applications. The limitations of spatial resolution due to bandwidth are of great concern in ultrasound medical imaging. The method of acoustic impedance matching between the piezoelectric element and medium is commonly used to obtain broad bandwidth and high resolution. In this study, an optimized backing layer design was proposed to broaden the bandwidth by adding a tunable acoustic impedance matching layer of backing (AIMLB) between the backing layer and the piezoelectric ceramic element. The Mason equivalent circuit method was used to analyze the effect of the backing material composition and its structure on the bandwidth of the transducer. The optimized transducer was simulated using the finite-element method with the PZFlex software. Based on the PZFlex simulations, a 20-MHz ultrasonic transducer using the AIMLB with a bandwidth of approximately 92.29% was fabricated. The experimental results were in good agreement with the simulations. The ultrasonic imaging indicated that the designed ultrasonic transducer with an additional AIMLB had high performance with good imaging capability.

30 June 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
Dongdong ChenDongdong Chen
Dongdong Chen
LWLinwei Wang
Linwei Wang
XLXingjun Luo
Xingjun Luo
Chunlong FeiChunlong Fei
Chunlong Fei
DI LIDI LI
DI LI
Yintang YangYintang Yang
Yintang Yang
A piezoelectric ultrasonic transducer (PUT) is widely used in nondestructive testing, medical imaging, and particle manipulation, etc., and the performance of the PUT determines its functional performance and effectiveness in these applications. The optimization design method of a PUT is very important for the fabrication of a high-performance PUT. In this paper, traditional and efficient optimization design methods for a PUT are presented. The traditional optimization design methods are mainly based on an analytical model, an equivalent circuit model, or a finite element model and the design parameters are adjusted by a trial-and-error method, which relies on the experience of experts and has a relatively low efficiency. Recently, by combining intelligent optimization algorithms, efficient optimization design methods for a PUT have been developed based on a traditional model or a data-driven model, which can effectively improve the design efficiency of a PUT and reduce its development cycle and cost. The advantages and disadvantages of the presented methods are compared and discussed. Finally, the optimization design methods for PUT are concluded, and their future perspectives are discussed.