Marco Pontin

Dr. Marco Pontin

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2024 in Science Robotics
Verified
Journal Article
Closed access
MPMarco Pontin
Marco Pontin
DDDana D. Damian
Dana D. Damian
Resilience is crucial for the self-preservation of biological systems: Humans recover from wounds thanks to an immune system that autonomously enacts a multistage response to promote healing. Similar passive mechanisms can enable pneumatic soft robots to overcome common faults such as bursts originating from punctures or overpressurization. Recent technological advancements, ranging from fault-tolerant controllers for robot reconfigurability to self-healing materials, have paved the way for robot resilience. However, these techniques require powerful processors and large datasets or external hardware. How to extend the operational life span of damaged soft robots with minimal computational and physical resources remains unclear. In this study, we demonstrated a multimodal pneumatic soft valve capable of passive resilient reactions, triggered by faults, to prevent or isolate damage in soft robots. In its forward operation mode, the valve, requiring a single supply pressure, isolated punctured soft inflatable elements from the rest of the soft robot in as fast as 21 milliseconds. In its reverse operation mode, the valve can passively protect robots against overpressurization caused by external disturbances, avoiding plastic deformations and bursts. Furthermore, the two modes combined enabled the creation of an endogenously controlled valve capable of autonomous burst isolation. We demonstrated the passive and quick response and the possibility of monolithic integration of the soft valve in grippers and crawling robots. The approach proposed in this study provides a distributed small-footprint alternative to controller-based resilience and is expected to help soft robots achieve uninterrupted long-lasting operation.

5 October 2020 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
MPMarco Pontin
Marco Pontin
DDDana D. Damian
Dana D. Damian
In the development of surgical technologies, one of the challenges in their initial validation has been the creation of accurate bench-top tissue phantoms. Tissue phantoms made of elastomeric material have fixed mechanical properties and are not able to increase in size, so they cannot mimic growth process or change in mechanical properties of their real counterparts. In this work we present a novel real-time soft tissue simulator aimed at testing the in vivo dynamic behavior of robotic implants. The simulator is capable of reproducing mechanical properties of the biological tissue, e.g. viscoelasticity, as well as its metabolism, being able to grow up to 260 mm. A control strategy based on impedance control enables the simulation of changing mechanical properties in real-time, in order to recreate conditions such as fibrosis or tissue scarring. We finally show the platform in use with a soft implant. The electric actuation in conjunction with the 500 Hz control loop frequency guarantees fast and accurate response. We believe our platform has the potential to reduce the need for in vivo preclinical studies and shorten the path to clinical experimentation.

8 February 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
MPMarco Pontin
Marco Pontin
DDDana D. Damian
Dana D. Damian
Robotic implants for real-time and long-term monitoring and therapies are being researched and could open new frontiers in the medical field. For these devices to see widespread adoption, though, key challenges still need to be overcome, including reliability. Over the years, many computational techniques have been developed to impart fault-tolerance to robots and industrial plants. However, the application of these approaches to robotic implants is still challenging, due to the lack of information about the complex behavior of soft tissue (e.g. growth, viscoelasticity) and robot-tissue interaction. In this paper, a novel fault detection framework for a flexible extendable robotic implant is presented. Based on Canonical Correlation Analysis, the approach exploits the flexibility of the robot to extrapolate information for fault identification purposes. The experiments are conducted with a soft tissue simulator, which can emulate the viscoelastic properties of tissue as well as its growth, providing a realistic testing platform. The experiments prove the reliability of the flexible extendable robotic implant and its robustness to system-level external disturbances. Long-term tests are also presented, where the implant extends 80 mm, to its full length, counteracting simulated hardware faults over a 24-hour period, and provide a promising basis for future in-vivo trials.

25 November 2025
Verified
Book Chapter
Closed access
PDF file
DWDylan Wilson
Dylan Wilson
MPMarco Pontin
Marco Pontin
PWPeter Walters
Peter Walters
PMPerla Maiolino
Perla Maiolino

1 November 2026 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
GCGiammarco Caroleo
Giammarco Caroleo
TMTimothee Mahamoodally
Timothee Mahamoodally
MMMatteo Manzardo
Matteo Manzardo
JJJin Jin
Jin Jin
MPMarco Pontin
Marco Pontin
MFMaurice Fallon
Maurice Fallon