31 January 2018 in Science Robotics
A robotic implant for inducing tissue growth in tubular organs is demonstrated through esophageal lengthening in swine.
24 July 2024 in Science Robotics
Resilience is crucial for the self-preservation of biological systems: Humans recover from wounds thanks to an immune system that autonomously enacts a multistage response to promote healing. Similar passive mechanisms can enable pneumatic soft robots to overcome common faults such as bursts originating from punctures or overpressurization. Recent technological advancements, ranging from fault-tolerant controllers for robot reconfigurability to self-healing materials, have paved the way for robot resilience. However, these techniques require powerful processors and large datasets or external hardware. How to extend the operational life span of damaged soft robots with minimal computational and physical resources remains unclear. In this study, we demonstrated a multimodal pneumatic soft valve capable of passive resilient reactions, triggered by faults, to prevent or isolate damage in soft robots. In its forward operation mode, the valve, requiring a single supply pressure, isolated punctured soft inflatable elements from the rest of the soft robot in as fast as 21 milliseconds. In its reverse operation mode, the valve can passively protect robots against overpressurization caused by external disturbances, avoiding plastic deformations and bursts. Furthermore, the two modes combined enabled the creation of an endogenously controlled valve capable of autonomous burst isolation. We demonstrated the passive and quick response and the possibility of monolithic integration of the soft valve in grippers and crawling robots. The approach proposed in this study provides a distributed small-footprint alternative to controller-based resilience and is expected to help soft robots achieve uninterrupted long-lasting operation.
29 January 2020 in IEEE Transactions on Medical Robotics and Bionics
Therapies for tissue repair and regeneration have remained sub-optimal, with limited approaches investigated to improve their effectiveness, dynamic and control response. We introduce a Soft Pneumatic Helically-Interlayered Actuator (SoPHIA) for tissue repair and regeneration of tubular tissues. The actuator features shape configurability in two and three dimensions for minimal or non-invasive in vivo implantation; multi-modal therapy to apply mechanical stimulation axially and radially, in accordance to the anatomy of tubular tissues; and anti-buckling structural strength. We present a model and characteristics of this soft actuator. SoPHIA reaches up to 36.3% of elongation with respect to its initial height and up to 7 N of force when pressurized at 38 kPa against anatomically-realistic spatial constraints. Furthermore, we introduce the capabilities of a physical in vivo simulator of biological tissue stiffness and growth, for the evaluation of the soft actuator in physiologically-relevant conditions. Lastly, we propose a model-based multi-stage control of the axial elongation of the actuator according to the tissue’s physiological response. SoPHIA has the potential to reduce the invasiveness of surgical interventions and increase the effectiveness in growing tissue due to its mechanically compliant, configurable and multi-modal design.
2 February 2022 in Cyborg and Bionic Systems
Technologies that provide mechanical assistance are required in the medical field, such as implants that regenerate tissue through elongation and stimulation. One of the challenges is to develop actuators that combine the benefits of high axial extension at low pressures, modularity, multifunction, and load-bearing capabilities into one design while maintaining their shape and softness. Overcoming such a challenge will provide implants with enhanced capacity for mechanical assistance to induce tissue regeneration. We introduce two novel actuators (M2H) built of stacked Hyperelastic Ballooning Membrane Actuators (HBMAs) that can be realized using helical and toroidal configurations. By restraining the HBMA expansion deterministically using a semisoft exoskeleton, the actuators are endowed with axial extension and radial expansion capabilities. These actuators are thus built of modules that can be configured to different therapeutical needs and multifunctionality, to provide anatomically congruent stimulation. We present the design, fabrication, testing, and numerical and experimental validation of the M2H-HBMAs. They can axially extend up to % and % in their helical and toroidal configurations at input pressures as low as and kPa, respectively. If the axial extension module is used separately, its extension capacity reaches %. The M2H-HBMAs can perform independent and simultaneous expansion and extension motions with negligible intraluminal deformation as well as stand at least kg of axial force without collapsing. The M2H-HBMAs overcome the limitations of hyperexpanding machines that show low resistance to load. We envisage M2H-HBMAs as promising tools to perform tissue regeneration procedures.
31 January 2020 in IEEE Robotics and Automation Letters
Remotely controllable and reversible adhesion is highly desirable for surgical operations: it can provide the possibility of non-invasive surgery, flexibility in fixing a patch and surgical manipulation via sticking. In our previous work, we developed a remotely controllable, ingestible, and deployable pill for use as a patch in the human stomach. In this study, we focus on magnetically facilitated reversible adhesion and develop a suction-based adhesive mechanism as a solution for non-invasive and autonomous adhesion of patches. We present the design, model, and fabrication of a magnet-embedded elastomeric suction cup. The suction cup can be localised, navigated, and activated or deactivated in an autonomous way; all realised magnetically with a pre-programmed fashion. The use of the adhesion mechanism is demonstrated for anchoring and carrying, for patching an internal organ surface and for an object removal, respectively.
7 July 2020 in IEEE Transactions on Biomedical Engineering
Objective: Implantable technologies should be mechanically compliant with the tissue in order to maximize tissue quality and reduce inflammation during tissue reconstruction. We introduce the development of a flexible and expandable implantable robotic (FEIR) device for the regenerative elongation of tubular tissue by applying controlled and precise tension to the target tissue while minimizing the forces produced on the surrounding tissue. Methods: We introduce a theoretical framework based on iterative beam theory static analysis for the design of an expandable robot with a flexible rack. The model takes into account the geometry and mechanics of the rack to determine a trade-off between its stiffness and capability to deliver the required tissue tension force. We empirically validate this theory on the benchtop and with biological tissue. Results: We show that FEIR can apply the required therapeutical forces on the tissue while reducing the amount of force it applies to the surrounding tissues as well as reducing self-damage. Conclusion: The study demonstrates a method to develop robots that can change size and shape to fit their dynamic environment while maintaining the precision and delicacy necessary to manipulate tissue by traction. Significance: The method is relevant to designers of implantable technologies. The robot is a precursor medical device for the treatment of Long-Gap Esophageal Atresia and Short Bowel Syndrome.