Paula Martínez-Pérez

Dr. Paula Martínez-Pérez

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2019 in Beilstein Journal of Nanotechnology
Verified
Journal Article
Open access
PDF file
PMPaula Martínez-Pérez
Paula Martínez-Pérez
JGJaime Garcia-Ruperez
Jaime Garcia-Ruperez
Porous materials have become one of the best options for the development of optical sensors, since they maximize the interaction between the optical field and the target substances, which boosts the sensitivity. In this work, we propose the use of a readily available mesoporous material for the development of such sensors: commercial polycarbonate track-etched membranes. In order to demonstrate their utility for this purpose, we firstly characterized their optical response in the near-infrared range. This response is an interference fringe pattern, characteristic of a Fabry–Pérot interferometer, which is an optical device typically used for sensing purposes. Afterwards, several refractive index sensing experiments were performed by placing different concentrations of ethanol solution on the polycarbonate track-etched membranes. As a result, a sensitivity value of around 56 nm/RIU was obtained and the reusability of the substrate was demonstrated. These results pave the way for the development of optical porous sensors with such easily available mesoporous material.

28 April 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
PMPaula Martínez-Pérez
Paula Martínez-Pérez
MGMaria Isabel Gómez Gómez
Maria Isabel Gómez Gómez
TATodora Ivanova Angelova
Todora Ivanova Angelova
AGAmadeu Griol
Amadeu Griol
JHJuan Hurtado
Juan Hurtado
JGJaime Garcia-Ruperez
Jaime Garcia-Ruperez
Thrombin generation is a complex and finely regulated pathway that provokes dynamical changes of thrombin concentration in blood when a vascular injury occurs. In order to characterize the initiation phase of such process, when thrombin concentration is in the nM range, a label-free optical aptasensor is proposed here. This aptasensor combines a 1D photonic crystal structure consisting of a silicon corrugated waveguide with thrombin binding aptamers on its surface as bioreceptors. As a result, this aptasensor has been demonstrated to specifically detect thrombin concentrations ranging from 270 pM to 27 nM with an estimated detection limit of 33.5 pM and a response time of ~2 min. Furthermore, it has also been demonstrated that this aptasensor is able to continuously respond to consecutive increasing concentrations of thrombin and to detect binding events as they occur. All these features make this aptasensor a good candidate to continuously study how thrombin concentration progressively increases during the initiation phase of the coagulation cascade.

1 June 2019 in Computational Biology and Chemistry
Verified
Journal Article
Closed access
JSJad SABEK
Jad SABEK
PMPaula Martínez-Pérez
Paula Martínez-Pérez
JGJaime García-Rupérez
Jaime García-Rupérez

11 April 2025 in ACS Applied Nano Materials
Verified
Journal Article
Open access
Johannes Wilhelm GoesslingJohannes Wilhelm Goessling
Johannes Wilhelm Goessling
PMPaula Martínez-Pérez
Paula Martínez-Pérez
LRLaura Rodriguez-Lorenzo
Laura Rodriguez-Lorenzo
PBPedro Braga-Fernandes
Pedro Braga-Fernandes
Begoña EspiñaBegoña Espiña
Begoña Espiña
MLMartin Lopez-Garcia
Martin Lopez-Garcia
Photonic band gap-based sensors can detect small variations in the refractive index of surrounding media, facilitating the precise detection of changes in their environment. In this proof-of-concept study, we demonstrate that biosilica produced by single-cell microalgae called diatoms can work as a photonic crystal slab sensor. We exploited the pseudo photonic bandgap (pseudo-PBG) produced by the highly periodic nanoscale morphology to detect the presence of relevant chemical elements in solutions. We demonstrate that the pseudo-PBG of the natural system can be calibrated for refractive index changes in the environment using standard liquids. Subsequently, we demonstrate that the platform enables precise detection of minute refractive index variations, accurate to the second decimal place, caused by concentration changes induced by analytes, such as magnesium chloride and d-glucose. This underscores the potential of nanostructured biosilica as an advanced platform for photonic sensing. In addition, we show that it is possible to customize the working spectral region by surface functionalization using titanium dioxide nanoparticles that modify the effective refractive index of the biosilica and therefore change the spectral properties of the pseudo-PBG. The results highlight the precision of this natural, biogenic nanomaterial and propose sustainable alternatives for developing photonic nanomaterials tailored for sensing applications and beyond.

26 November 2020 in Chemosensors
Verified
Journal Article
Open access
PDF file
PMPaula Martínez-Pérez
Paula Martínez-Pérez
Salvador Ponce-AlcántaraSalvador Ponce-Alcántara
Salvador Ponce-Alcántara
NMNieves Murillo
Nieves Murillo
APANA PEREZ-MARQUEZ
ANA PEREZ-MARQUEZ
JMJon Maudes
Jon Maudes
JGJaime Garcia-Ruperez
Jaime Garcia-Ruperez
Polymeric nanofiber matrices are promising structures to develop biosensing devices due to their easy and affordable large-scale fabrication and their high surface-to-volume ratio. In this work, the suitability of a polyamide 6 nanofiber matrix for the development of a label-free and real-time Fabry–Pérot cavity-based optical biosensor was studied. For such aim, in-flow biofunctionalization of nanofibers with antibodies, bound through a protein A/G layer, and specific biodetection of 10 µg/mL bovine serum albumin (BSA) were carried out. Both processes were successfully monitored via reflectivity measurements in real-time without labels and their reproducibility was demonstrated when different polymeric nanofiber matrices from the same electrospinning batch were employed as transducers. These results demonstrate not only the suitability of correctly biofunctionalized polyamide 6 nanofiber matrices to be employed for real-time and label-free specific biodetection purposes, but also the potential of electrospinning technique to create affordable and easy-to-fabricate at large scale optical transducers with a reproducible performance.

6 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Salvador Ponce-AlcántaraSalvador Ponce-Alcántara
Salvador Ponce-Alcántara
PMPaula Martínez-Pérez
Paula Martínez-Pérez
APANA PEREZ-MARQUEZ
ANA PEREZ-MARQUEZ
JMJon Maudes
Jon Maudes
NMNieves Murillo
Nieves Murillo
JGJaime Garcia-Ruperez
Jaime Garcia-Ruperez
In order to increase the sensitivity of a sensor, the relationship between its volume and the surface available to be functionalized is of great importance. Accordingly, porous materials are becoming very relevant, because they have a notable surface-to-volume ratio. Moreover, they offer the possibility to infiltrate the target substances on them. Among other porous structures, polymeric nanofibers (NFs) layers fabricated by electrospinning have emerged as a very promising alternative to low-cost and easy-to-produce high-performance photonic sensors. However, experimental results show a spectrum drift when performing sensing measurements in real-time. That drift is responsible for a significant error when trying to determine the refractive index variation for a target solution, and, because of that, for the detection of the presence of certain analytes. In order to avoid that problem, different chemical and thermal treatments were studied. The best results were obtained for thermal steps at 190 °C during times between 3 and 5 h. As a result, spectrum drifts lower than 5 pm/min and sensitivities of 518 nm/refractive index unit (RIU) in the visible range of the spectrum were achieved in different electrospun NFs sensors.