Todora Ivanova Angelova

Todora Ivanova Angelova


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
AGAmadeu Griol
Amadeu Griol
SPSergio Peransi
Sergio Peransi
MRManuel Rodrigo
Manuel Rodrigo
JHJuan Hurtado
Juan Hurtado
LBLaurent Bellieres
Laurent Bellieres
AGAlessandro Giusti
Alessandro Giusti
In this paper we introduce a field diagnostic device based on the combination of advanced bio-sensing and photonics technologies, to tackle emerging and endemic viruses causing swine epidemics, and consequently significant economic damage in farms. The device is based on the use of microring resonators fabricated in silicon nitride with CMOS compatible techniques. In the paper, the designed and fabricated photonic integrated circuit (PIC) sensors are presented and characterized, showing an optimized performance in terms of optical losses (30 dB per ring) and extinction ration for ring resonances (15 dB). Furthermore, the results of an experiment for porcine circovirus 2 (PCV2) detection by using the developed biosensors are presented. Positive detection for different virus concentrations has been obtained. The device is currently under development in the framework of the EU Commission co-funded project SWINOSTICS.

28 April 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
PMPaula Martínez-Pérez
Paula Martínez-Pérez
MGMaria Isabel Gómez Gómez
Maria Isabel Gómez Gómez
TATodora Ivanova Angelova
Todora Ivanova Angelova
AGAmadeu Griol
Amadeu Griol
JHJuan Hurtado
Juan Hurtado
JGJaime Garcia-Ruperez
Jaime Garcia-Ruperez
Thrombin generation is a complex and finely regulated pathway that provokes dynamical changes of thrombin concentration in blood when a vascular injury occurs. In order to characterize the initiation phase of such process, when thrombin concentration is in the nM range, a label-free optical aptasensor is proposed here. This aptasensor combines a 1D photonic crystal structure consisting of a silicon corrugated waveguide with thrombin binding aptamers on its surface as bioreceptors. As a result, this aptasensor has been demonstrated to specifically detect thrombin concentrations ranging from 270 pM to 27 nM with an estimated detection limit of 33.5 pM and a response time of ~2 min. Furthermore, it has also been demonstrated that this aptasensor is able to continuously respond to consecutive increasing concentrations of thrombin and to detect binding events as they occur. All these features make this aptasensor a good candidate to continuously study how thrombin concentration progressively increases during the initiation phase of the coagulation cascade.

27 June 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
MLMiguel Sinusia Lozano
Miguel Sinusia Lozano
IBIgnacio Bernat-Montoya
Ignacio Bernat-Montoya
TATodora Ivanova Angelova
Todora Ivanova Angelova
ABAlberto Boscá
Alberto Boscá
FDFrancisco J. Díaz-Fernández
Francisco J. Díaz-Fernández
Víctor Jesús Gómez HernándezVíctor Jesús Gómez Hernández
Víctor Jesús Gómez Hernández
In this work, we study the influence of the different surface terminations of c-plane sapphire substrates on the synthesis of graphene via plasma-enhanced chemical vapor deposition. The different terminations of the sapphire surface are controlled by a plasma process. A design of experiments procedure was carried out to evaluate the major effects governing the plasma process of four different parameters: i.e., discharge power, time, pressure and gas employed. In the characterization of the substrate, two sapphire surface terminations were identified and characterized by means of contact angle measurements, being a hydrophilic (hydrophobic) surface and the fingerprint of an Al- (OH-) terminated surface, respectively. The defects within the synthesized graphene were analyzed by Raman spectroscopy. Notably, we found that the ID/IG ratio decreases for graphene grown on OH-terminated surfaces. Furthermore, two different regimes related to the nature of graphene defects were identified and, depending on the sapphire terminated surface, are bound either to vacancy or boundary-like defects. Finally, studying the density of defects and the crystallite area, as well as their relationship with the sapphire surface termination, paves the way for increasing the crystallinity of the synthesized graphene.