Quentin Gallas

Dr. Quentin Gallas

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2016 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
CGCécile Ghouila-Houri
Cécile Ghouila-Houri
JCJ. Claudel
J. Claudel
JGJ.-C. Gerbedoen
J.-C. Gerbedoen
QGQuentin Gallas
Quentin Gallas
EGE. Garnier
E. Garnier
PPP. Pernod
P. Pernod
We present an efficient and high-sensitive thermal micro-sensor for near wall flow parameters measurements. By combining substrate-free wire structure and mechanical support using silicon oxide micro-bridges, the sensor achieves a high temperature gradient, with wires reaching 1 mm long for only 3 μm wide over a 20 μm deep cavity. Elaborated to reach a compromise solution between conventional hot-films and hot-wire sensors, the sensor presents a high sensitivity to the wall shear stress and to the flow direction. The sensor can be mounted flush to the wall for research studies such as turbulence and near wall shear flow analysis, and for technical applications, such as flow control and separation detection. The fabrication process is CMOS-compatible and allows on-chip integration. The present letter describes the sensor elaboration, design, and micro-fabrication, then the electrical and thermal characterizations, and finally the calibration experiments in a turbulent boundary layer wind tunnel.

11 September 2017 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
CGCécile Ghouila-Houri
Cécile Ghouila-Houri
ATA. Talbi
A. Talbi
RVR. Viard
R. Viard
MMM. Moutaouekkil
M. Moutaouekkil
Omar ElmazriaOmar Elmazria
Omar Elmazria
PPP. Pernod
P. Pernod
This letter describes and discusses the design and testing of an efficient nanogap Pirani micro-sensor for pressure measurements in a wide range with a maximum sensitivity around atmospheric pressure. The structure combines a substrate-free heated wire and a mechanical support made of silicon oxide micro-bridges allowing both a constant nanoscale gap between the wire and the substrate and a 1 mm long and 3 μm wide wire. The high aspect ratio of the wire provides a uniform heating profile along the wire and contributes to low pressure detection. On the contrary, both the nanoscale gap and the short wire length between two micro-bridges contribute to shift the high limit of the pressure range. When tested between 10 kPa and 800 kPa, the sensor presents a wide measurement range, not fully reached by the experiments, with a maximum of sensitivity close to the atmospheric pressure and performances with up to 38%/dec sensitivity when operating in a constant temperature mode with an overheat of 20 °C.

1 June 2019 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
COC. Ott
C. Ott
QGQuentin Gallas
Quentin Gallas
JDJ. Delva
J. Delva
MLM. Lippert
M. Lippert
LKL. Keirsbulck
L. Keirsbulck

15 April 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CGCécile Ghouila-Houri
Cécile Ghouila-Houri
ATAbdelkrim Talbi
Abdelkrim Talbi
RVRomain Viard
Romain Viard
QGQuentin Gallas
Quentin Gallas
EGEric Garnier
Eric Garnier
PPPhilippe Pernod
Philippe Pernod
This paper presents and discusses the results obtained with a MEMS (Micro-Electro-Mechanical System) high temperature gradient sensor for time-averaged and fluctuating skin-friction measurements in highly turbulent flows. Designed as a robust wall-mounted suspended hot-wire structure, the micro-sensor was made using conventional microfabrication techniques, compatible with microelectronics for designing integrated smart systems. Successfully implemented into two air wind tunnels, the sensor was tested in a large range of turbulent flows, with mainstream velocities going up to 270 m/s (Mach number of 0.79), which corresponds to the mean velocity of airliner cruise flights. The experiments demonstrated the wide dynamic range of the micro-sensor without reaching its limits. The micro-sensor thereby demonstrated its value for measuring turbulence in aerodynamic applications, being particularly suitable for aeronautics.

5 September 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
CGCécile Ghouila-Houri
Cécile Ghouila-Houri
RSRalph Sindjui
Ralph Sindjui
MMMohammed Moutaouekkil
Mohammed Moutaouekkil
Omar ElmazriaOmar Elmazria
Omar Elmazria
QGQuentin Gallas
Quentin Gallas
PPPhilippe Pernod
Philippe Pernod
This paper presents a high sensitive micro-sensor designed for pressure measurements in a wide range around atmospheric pressure, for application in aerodynamics. The sensor is a temperature-resistance transducer operating with the Pirani effect, which states that below a certain pressure limit, the thermal conductivity of a gas is pressure-dependent. The sensor presents a wide measurement range between 10 kPa and about 800 kPa, in both constant current and constant temperature mode. The last mode enables high-sensitive measurements with a maximum of sensitivity around atmospheric pressure, enabling the use of the sensor for applications in aerodynamics and fluid dynamics, such as active flow control.

9 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
CGCécile Ghouila-Houri
Cécile Ghouila-Houri
QGQuentin Gallas
Quentin Gallas
EGEric Garnier
Eric Garnier
AMAlain Merlen
Alain Merlen
RVRomain Viard
Romain Viard
PPPhilippe Pernod
Philippe Pernod
This paper presents an efficient and high-sensitive micro-sensor designed for wall shear stress measurement. The main technical application targeted is flow separation detection for closed-loop active flow control. The sensor is a temperature-resistance transducer operating on heat transfer. The device is micro-structured with three substrate-free wires presenting a high aspect ratio, and periodic perpendicular micro-bridges ensuring mechanical toughness and thermal insulation. This design achieves a homogeneous temperature distribution along the wires. Welded on a flexible printed circuit, the sensor is wall-mounted on a wind tunnel. The experiments, conducted in both attached and separated flow configurations, demonstrate the sensor sensitivity to wall shear stress up to 2.4 Pa and the ability of the 3-wires based design to perform flow direction sensing for back-flow detection.