Simonetta Resta

Dr. Simonetta Resta


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MMMaurilio Marcacci
Maurilio Marcacci
AFALBERTO FAVARO
ALBERTO FAVARO
GAGregorio Alberto
Gregorio Alberto
LALuca Alberti
Luca Alberti
SRSimonetta Resta
Simonetta Resta
FIFrancesco Iacono
Francesco Iacono
Background/Objectives: This study introduces and evaluates a novel surgical technique for total knee arthroplasty (TKA) that uses the trochlear groove bisector (TGB) as an anatomical landmark to achieve kinematic alignment of the femoral component in the coronal plane. The aim of the present retrospective observational analysis was to assess the reproducibility and accuracy of this approach and to report preliminary clinical outcomes. Methods: Twenty-eight TKA procedures were performed using the TGB-guided alignment technique. Preoperative planning and postoperative assessments were conducted on long-leg weight-bearing radiographs to measure the agreement between planned and achieved alignment, analysed using Bland–Altman statistics. Functional outcomes were evaluated at 12 months with the Knee Society Score (KSS), Forgotten Joint Score (FJS), and patient satisfaction. Results: The mean difference between planned and post-operative mLDFA was −0.3° ± 0.65°, with a root mean square error (RMSE) of 0.7°, demonstrating high accuracy and reproducibility. Postoperative outcomes showed mean KSS (knee = 89.6, function = 91.4), FJS = 69.6 ± 12, mean flexion = 124.6°, and mean HKA = 178°. Ninety percent of patients reported being satisfied or very satisfied at 12 months. Conclusions: The TGB-based technique offers a reliable, easily applicable method for restoring native femoral alignment in TKA using standard instrumentation. It allows accurate prediction of postoperative alignment and achieves favourable early functional outcomes. While currently limited to moderate varus deformities, future developments integrating 3D or CT-based planning may extend its applicability to more complex cases.

14 October 2026 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
LBLuca Bertolino
Luca Bertolino
APAurelio Picchi
Aurelio Picchi
SRSimonetta Resta
Simonetta Resta
POPaolo Oliva
Paolo Oliva
AFAndrea Fidanza
Andrea Fidanza
TBTommaso Bonanzinga
Tommaso Bonanzinga
Background/Objective: ACL reconstruction is among the most common orthopedic procedures, yet autografts and allografts carry significant limitations including donor site morbidity and immunological risk. PET-based synthetic grafts such as LARS were introduced to address these shortcomings, but their biologically inert surface raises concerns regarding cellular adhesion and host tissue integration. A new generation of functionalized PET scaffolds has emerged over the past decade, yet no systematic review has summarized this evidence since 2011. The present review aims to evaluate the biological and mechanical effects of novel functionalized PET scaffolds for ACL reconstruction. Methods: A systematic review was conducted in accordance with the PRISMA 2020 statement. PubMed, Embase, and Web of Science were searched up to 20 August 2026 for original studies investigating chemically or biologically modified polyethylene terephthalate grafts for Anterior cruciate ligament reconstruction and reporting in vitro outcomes, in vivo animal model data, and mechanical properties. Two independent reviewers performed screening, full-text assessment, and data extraction. Results: Seventeen studies met the inclusion criteria. Functionalization strategies included physical deposition, chemical surface modification, biomimetic mineral coatings, and hybrid composite fabrication. Across all studies, functionalized PET scaffolds generally demonstrated improved performance compared with unmodified PET controls. In vitro , enhanced cellular proliferation, upregulation of osteogenic markers, and increased angiogenic activity were observed. In vivo , improved graft–bone integration was demonstrated by higher bone volume fraction, reduced tunnel area, and decreased interface width. Post-implantation ultimate load to failure and stiffness generally favored functionalized PET scaffolds, though both parameters remained inferior to the native ACL in direct comparisons. Conclusion: Surface biofunctionalization appears to enhance the biological and mechanical performance of PET-based scaffolds for ACL reconstruction, suggesting that surface bioengineering may play an important role in promoting biological integration and functional performance. These findings indicate that functionalized PET scaffolds could represent potential donor-independent alternatives for ACL reconstruction and may warrant further investigation as synthetic ligament substitutes. However, a persistent mechanical gap versus native ligament tissue remains. These findings should be interpreted with caution due to methodological heterogeneity, predominant use of small animal models, and inconsistent outcome reporting across the included studies.