ALBERTO FAVARO

Dr. ALBERTO FAVARO

Humanitas University, Rozzano, Italy
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
AFALBERTO FAVARO
ALBERTO FAVARO
ASAlice Segato
Alice Segato
FMFederico Muretti
Federico Muretti
EMElena De Momi
Elena De Momi
Path planning algorithms for steerable needles in medical applications must guarantee the anatomical obstacle avoidance, reduce the insertion length, and ensure the compliance with the needle kinematics. The majority of the solutions from the literature focus either on fast computation or on path optimality, the former at the expense of suboptimal paths, the latter by making unbearable the computation in case of a high-dimensional workspace. In this article, we implement a three-dimensional path planner for neurosurgical applications, which keeps the computational cost consistent with standard preoperative planning algorithms and fine-tunes the estimated pathways in accordance to multiple optimization objectives. From a user-defined entry point, our method confines a sample-based path search within a subsection of the original workspace considering the degree of curvature admitted by the needle. An evolutionary optimization procedure is used to maximize the obstacle avoidance and reduce the insertion length. The pool of optimized solutions is examined through a cost function to determine the best path. Simulations on one dataset showed the ability of the planner to save time and overcome the state of the art in terms of obstacle avoidance, insertion length, and probability of failure, proving this algorithm as a valid planning method for complex environments.

6 August 2019 in Frontiers in Robotics and AI
Verified
Journal Article
Open access
ASAlice Segato
Alice Segato
VPValentina Pieri
Valentina Pieri
AFALBERTO FAVARO
ALBERTO FAVARO
MRMarco Riva
Marco Riva
AFAndrea Falini
Andrea Falini
ACAntonella Castellano
Antonella Castellano
Deep Brain Stimulation (DBS) is a neurosurgical procedure consisting in the stereotactic implantation of stimulation electrodes to specific brain targets, such as deep gray matter nuclei. Current solutions to place the electrodes rely on rectilinear stereotactic trajectories (RTs) manually defined by surgeons, based on pre-operative images. An automatic path planner that accurately targets subthalamic nuclei (STN) and safeguards critical surrounding structures is still lacking. Also, robotically-driven curvilinear trajectories (CTs) computed on the basis of state-of-the-art neuroimaging would decrease DBS invasiveness, circumventing patient-specific obstacles. This work presents a new algorithm able to estimate a pool of DBS curvilinear trajectories for reaching a given deep target in the brain, in the context of the EU's Horizon EDEN2020 project. The prospect of automatically computing trajectory plans relying on sophisticated newly engineered steerable devices represents a breakthrough in the field of microsurgical robotics. By tailoring the paths according to single-patient anatomical constraints, as defined by advanced preoperative neuroimaging including diffusion MR tractography, this planner ensures a higher level of safety than the standard rectilinear approach. Ten healthy controls underwent Magnetic Resonance Imaging (MRI) on 3T scanner, including 3DT1-weighted sequences, 3Dhigh-resolution time-of-flight MR angiography (TOF-MRA) and high angular resolution diffusion MR sequences. A probabilistic q-ball residual-bootstrap MR tractography algorithm was used to reconstruct motor fibers, while the other deep gray matter nuclei surrounding STN and vessels were segmented on T1 and TOF-MRA images, respectively. These structures were labeled as obstacles. The reliability of the automated planner was evaluated; CTs were compared to RTs in terms of efficacy and safety. Targeting the anterior STN, CTs performed significantly better in maximizing the minimal distance from critical structures, by finding a tuned balance between all obstacles. Moreover, CTs resulted superior in reaching the center of mass (COM) of STN, as well as in optimizing the entry angle in STN and in the skull surface.

1 May 2018
Verified
Conference Paper
Closed access
AFALBERTO FAVARO
ALBERTO FAVARO
LCLeonardo Cerri
Leonardo Cerri
SGStefano Galvan
Stefano Galvan
FBFerdinando Rodriguez Y Baena
Ferdinando Rodriguez Y Baena
EMElena De Momi
Elena De Momi
In this paper, an automatic planner for minimally invasive neurosurgery is presented. The solution provides the neurosurgeon with the best path to connect a user-defined entry point with a target in accordance with a specific cost function. The approach guarantees the avoidance of obstacles which can be found along the insertion pathway. The method is tailored to the EDEN2020* programmable bevel-tip needle, a multisegment steerable probe intended to be used to perform drug delivery for the treatment of glioblastomas. A sample-based heuristic search inspired by the BIT* algorithm is used to define the asymptotically-optimal solution in terms of path length, followed by a smoothing phase to meet the required kinematic constraints of the needle. To account for inaccuracies in catheter modeling, which could determine unexpected control errors over the insertion procedure, an uncertainty margin is defined in order to increase the algorithm's safety. The feasibility of the proposed solution was demonstrated by testing the method in simulated neurosurgical scenarios with different degrees of obstacle occupancy and against other sample-based algorithms present in literature: RRT, RRT* and an enhanced version of the RRT-Connect.

20 August 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
AFALBERTO FAVARO
ALBERTO FAVARO
RSRiccardo Secoli
Riccardo Secoli
FBFerdinando Rodriguez y Baena
Ferdinando Rodriguez y Baena
EMElena De Momi
Elena De Momi
Bevel-tip steerable needles for percutaneous intervention are prone to torsion determined by the interaction forces with the human tissue. If disregarded, torsion can affect the insertion accuracy inducing a change in the needle tip orientation, which is generally undetectable by tracking devices because of the small diameter of the needle. This paper presents a method for estimating the tip pose (i.e. position and orientation) of a programmable bevel-tip needle using a 2-D kinematic based Extended Kalman Filter (EKF), where the tip position of the two steering segments is used as input measurement. Simulation trials and experiments in phantom-brain gelatin were performed to prove the performance of the method and mimic real case scenarios. The solution presented shows state-of-the-art performance in needle pose estimation with a bounded positional error of <1mm and orientation error of <5deg.

16 April 2025 in Medicina
Verified
Journal Article
Open access
PDF file
LBLuca Bertolino
Luca Bertolino
MRMarta Bianca Maria Ranzini
Marta Bianca Maria Ranzini
AFALBERTO FAVARO
ALBERTO FAVARO
EBElena Bardi
Elena Bardi
FRFlavio Lorenzo Ronzoni
Flavio Lorenzo Ronzoni
TBTommaso Bonanzinga
Tommaso Bonanzinga
Background and Objectives: This scoping review explores the current state of the art of AI-based applications in the field of orthopedics, focusing on its implementation in diagnostic imaging and preoperative planning of knee joint procedures. Materials and Methods: The search was carried out using the recognized scholarly databases PubMed, Medline and Embase and was set to identify original research addressing AI applied to imaging in knee diagnosis and surgical planning, written in English and published up to January 2025. Results: The search produced 1612 papers, of which 36 were included in our review. All papers addressed AI applied to common imaging methods in clinical practice. Of these, thirty integrated AI-based tools with X-rays, one applied AI to X-rays to produce CT-like 3D reproductions, and two studies applied AI to MRI. Conclusions: Several AI tools have already been validated for enhancing the accuracy of measurements and detecting additional parameters in a shorter time compared to standard assessments. We expect these may soon be introduced into routine clinical practice to streamline a number of technical tasks and in some cases to replace the need for human intervention.

1 March 2018
Verified
Conference Paper
Closed access
AFALBERTO FAVARO
ALBERTO FAVARO
LCLeonardo Cerri
Leonardo Cerri
DSDavide Scorza
Davide Scorza
EMElena De Momi
Elena De Momi
The present work describes a novel approach to trajectory planning for minimally invasive surgery consisting of an algorithm able to provide the surgeon with multiple curvilinear paths to connect an entry area defined on the brain cortex to a specific target point in the brain. A criterion based on the minimum distance from the safety-critical brain structures (blood vessels, thalamus and ventricles) is used to rank the obtained trajectories. The solution is integrated onto the EDEN2020* programmable bevel-tip needle, a multi-segment probe whose steering ability derives from the offset generated on its tip, and provides a level of tolerance with respect to tracking errors arising from catheter model inaccuracies. The case of study of the work consists of a typical Deep Brain Stimulation scenario where tests have been performed in order to compare the result obtained from standard rectilinear trajectory planning against this novel curvilinear solution using the clearance from obstacles as an index of performance of the estimated solutions.