Ahmed Hassan

Dr. Ahmed Hassan

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in International Journal of Renewable Energy Research
Verified
Journal Article
Open access
PDF file
Mohammed Hamouda AliMohammed Hamouda Ali
Mohammed Hamouda Ali
AMAhm Mohammed
Ahm Mohammed
AHAhmed Hassan
Ahmed Hassan
AHMED MOHAMMED ATTIYA SOLIMANAHMED MOHAMMED ATTIYA SOLIMAN
AHMED MOHAMMED ATTIYA SOLIMAN
AHAhmed Hassan
Ahmed Hassan
Optimization of Reactive Power Dispatch Considering DG Units Uncertainty By Dandelion Optimizer Algorithm

21 November 2025 in Wind
Verified
Journal Article
Open access
PDF file
AEAreeg Ebrahiem Elngar
Areeg Ebrahiem Elngar
ASAsmaa sobhy Sabik
Asmaa sobhy Sabik
AHAhmed Hassan
Ahmed Hassan
ANAdel Saad Nada Saad Nada
Adel Saad Nada Saad Nada
Wind energy has become a cornerstone of sustainable electricity generation, yet the reliable integration of wind energy conversion systems (WECSs) into modern grids remains challenged by dynamic variations in wind speed and stringent fault ride-through (FRT) requirements. Among the available technologies, the Doubly Fed Induction Generator (DFIG) and the Permanent Magnet Synchronous Generator (PMSG) dominate commercial applications; however, a comprehensive comparative assessment under diverse grid and fault scenarios is still limited. This study addresses this gap by systematically evaluating the performance of DFIG- and PMSG-based WECSs across three operating stages: (i) normal operation at constant speed, (ii) variable wind speed operation, and (iii) grid fault conditions including single-line-to-ground, line-to-line, and three-phase faults. To enhance fault resilience, a DC-link Braking Chopper is integrated into both systems, ensuring a fair evaluation of transient stability and compliance with low-voltage ride-through (LVRT) requirements. The analysis, performed using MATLAB/Simulink, focuses on active and reactive power, rotor speed, pitch angle, and DC-link voltage dynamics. The results reveal that PMSG exhibits smoother transient responses and lower overshoot compared to DFIG. Under fault conditions, the DC-link Braking Chopper effectively suppresses voltage spikes in both systems, with DFIG achieving faster reactive power recovery in line with grid code requirements, while PMSG ensures more stable rotor dynamics with lower oscillations. The findings highlight the complementary strengths of both technologies and provide useful insights for selecting appropriate WECS configurations to improve grid integration and fault ride-through capability.

25 June 2026 in International Journal of Electrical and Electronics Research
Verified
Journal Article
Open access
PDF file
AHAhmed Hassan
Ahmed Hassan
MAMohammed Fathy Ahmed
Mohammed Fathy Ahmed
AHMED MOHAMMED ATTIYA SOLIMANAHMED MOHAMMED ATTIYA SOLIMAN
AHMED MOHAMMED ATTIYA SOLIMAN
Mohammed Hamouda AliMohammed Hamouda Ali
Mohammed Hamouda Ali
MSMohammed Shehata Seif
Mohammed Shehata Seif
This paper presents an improved Direct Power Control (DPC) approach applied to the Grid-Side Converter (GSC) of a wind-driven Permanent Magnet Synchronous Generator (PMSG). The proposed method modifies the conventional switching table by incorporating the errors of the direct and quadrature current components along with the filtered grid voltage vector. The objective is to enhance steady-state behavior and reduce power fluctuations. A comprehensive simulation model is developed in MATLAB/Simulink to assess system performance under different loading conditions and varying wind speeds. Furthermore, the system is evaluated under disturbance conditions, and a comparative validation is performed using classical DPC, Field-Oriented Control (FOC), and Space Vector Pulse Width Modulation (SVPWM)-based FOC. The obtained results confirm that the proposed method achieves improved harmonic and steady-state performance while preserving a relatively simple control structure. Moreover, the Total Harmonic Distortion (THD) of both grid voltage and current remains below 5% at the Point of Common Coupling, complying with IEEE-519 standards. These findings confirm the robustness and effectiveness of the modified DPC scheme in improving power quality and ensuring stable operation of PMSG-based Wind Energy Conversion Systems under variable operating conditions.