Debopam Datta

Debopam Datta


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2022 in IEEE Transactions on Quantum Engineering
Verified
Journal Article
Open access
KGKestutis Grigoras
Kestutis Grigoras
NYN. Yurttagul
N. Yurttagul
JKJ.-P. Kaikkonen
J.-P. Kaikkonen
EME. T. Mannila
E. T. Mannila
PEP. Eskelinen
P. Eskelinen
JGJ. Govenius
J. Govenius
We fabricate and characterize superconducting through-silicon vias and electrodes suitable for superconducting quantum processors. We measure internal quality factors of a million for test resonators excited at single-photon levels, on chips with superconducting vias used to stitch ground planes on the front and back sides of the chips. This resonator performance is on par with the state of the art for silicon-based planar solutions, despite the presence of vias. Via stitching of ground planes is an important enabling technology for increasing the physical size of quantum processor chips, and is a first step toward more complex quantum devices with three-dimensional integration.

2 July 2018 in IEEE Transactions on Nanobioscience
Verified
Journal Article
Closed access
SGShreya Ghosh
Shreya Ghosh
DDDebopam Datta
Debopam Datta
SCShreya Chaudhry
Shreya Chaudhry
MDMitra Dutta
Mitra Dutta
MSMichael A. Stroscio
Michael A. Stroscio
This paper reports an optical “TURN OFF” aptasensor, which is comprised of a deoxyribonucleic acid aptamer attached to a quantum dot on the 5' terminus and gold nanoparticle on the 3' terminus. The photoluminescence intensity is observed to decrease upon progressive addition of the target protein tumor necrosis factor-alpha (TNF-α) to the sensor. For PBS-based TNF-α samples, the beacon exhibited 19%-20% quenching at around 22 nM concentration. The photoluminescence intensity and the quenching efficiency showed a linear decrease and a linear increase, respectively, between 0 to 22.3 nM TNF-α. The detection limit of the sensor was found to be 97.2 pM. Specificity test results determined that the sensor has higher selectivity toward TNF-α than other control proteins such as C-reactive protein, albumin, and transferrin. The beacon successfully detected different concentrations of TNF-α in human serum-based samples exhibiting around 10% quenching efficiency at 12.5 nM of the protein.

18 July 2017 in Nanotechnology
Verified
Journal Article
Closed access
PDF file
DDDebopam Datta
Debopam Datta
KSKetaki Sarkar
Ketaki Sarkar
SMSouvik Mukherjee
Souvik Mukherjee
XMXenia Meshik
Xenia Meshik
MSMichael A. Stroscio
Michael A. Stroscio
MDMitra Dutta
Mitra Dutta
Quantum-dot (QD) based nanosensors are frequently used by researchers to detect small molecules, ions and different biomolecules. In this article, we present a sensor complex/system comprised of deoxyribonucleic acid (DNA) aptamer, gold nanoparticle and semiconductor QD, attached to a graphene oxide (GO) flake for detection of potassium. As reported herein, it is demonstrated that QD-aptamer-quencher nanosensor functions even when tethered to GO, opening the way to future applications where sensing can be accomplished simultaneously with other previously demonstrated applications of GO such as serving as a nanocarrier for drug delivery. Herein, it is demonstrated that the DNA based thrombin binding aptamer used in this study undergoes the conformational change needed for sensing even when the nanosensor complex is anchored to the GO. Analysis with the Hill equation indicates the interaction between aptamer and potassium follows sigmoidal Hill kinetics. It is found that the quenching efficiency of the optical sensor is linear with the logarithm of concentration from 1 pM to 100 nM and decreases for higher concentration due to unavailability of aptamer binding sites. Such a simple and sensitive optical aptasensor with minimum detection capability of 1.96 pM for potassium ion can also be employed in-vitro detection of different physiological ions, pathogens and disease detection methods.

27 May 2024 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
VMV. Y. Monarkha
V. Y. Monarkha
SSS. Simbierowicz
S. Simbierowicz
MBM. Borrelli
M. Borrelli
RGR. van Gulik
R. van Gulik
NDN. Drobotun
N. Drobotun
RLR. E. Lake
R. E. Lake
We report a comparative study on microwave control lines for a transmon qubit using (i) flexible stripline transmission lines and (ii) semi-rigid coaxial cables. During each experiment, we performed repeated measurements of the energy relaxation and coherence times of a transmon qubit using one of the wiring configurations. Each measurement run spanned 70–250 h of the measurement time, and four separate cooldowns were performed so that each configuration could be tested twice. From these datasets, we observe that changing the microwave control lines from coaxial cables to flexible stripline transmission lines does not have a measurable effect on coherence compared to thermal cycling the system or random coherence fluctuations. Our results open up the possibility of large-scale integration of qubit control lines with integrated component with planar layouts on flexible substrate.

5 March 2025 in Physical Review Applied
Verified
Journal Article
Closed access
EREwa Rej
Ewa Rej
RCRicha Cutting
Richa Cutting
JDJoe Depellette
Joe Depellette
DDDebopam Datta
Debopam Datta
NTNils Tiencken
Nils Tiencken
MSMika A. Sillanpää
Mika A. Sillanpää

1 March 2018 in Superlattices and Microstructures
Verified
Journal Article
Closed access
KSKetaki Sarkar
Ketaki Sarkar
DDDebopam Datta
Debopam Datta
DGDavid J. Gosztola
David J. Gosztola
FSFengyuan Shi
Fengyuan Shi
ANAlan Nicholls
Alan Nicholls
MDMitra Dutta
Mitra Dutta