Uwe Schmidt

Uwe Schmidt


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2017 in Energies
Verified
Journal Article
Open access
PDF file
AHAbdullah Hoshmeh
Abdullah Hoshmeh
USUwe Schmidt
Uwe Schmidt
The calculation of frequency-dependent cable parameters is essential for simulations of transient phenomena in electrical power systems. The simulation of transients is more complicated than the calculation of currents and voltages in the nominal frequency range. The model has to represent the frequency dependency and the wave propagation behavior of cable lines. The introduced model combines an improved subconductor method for the determination of the frequency-dependent parameters and a PI section wave propagation model. The subconductor method considers the skin and proximity effect in all conductors for frequency ranges up to few megahertz. The subconductor method method yields accurate results. The wave propagation part of the cable model is based on a cascaded PI section model. A modal transformation technique has been used for the calculation in the time domain. The frequency-dependent elements of the related modal transformation matrices have been fitted with rational functions. The frequency dependence of cable parameters has been reproduced using a vector fitting algorithm and has been implemented into an resistor-inductor-capacitor network (RLC network) for each PI section. The proposed full model has been validated with measured data.

19 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
BKBenjamin Küchler
Benjamin Küchler
USUwe Schmidt
Uwe Schmidt
JHJonathan Hänsch
Jonathan Hänsch
The design of every power supply system must guarantee the safety for human life even in the event of a fault. Due to the system change in the electrical power supply, the fault current contains more and more unknown shares of current harmonics. Especially in medium voltage grids, which are operated with resonant grounding, these are determining for the level of the single-pole ground fault current for determination of permissible touch voltages and compliance with the normative requirements of the European standard EN 50522 must therefore be re-evaluated. In its first part, this concept paper presents the frequency dependent principles of earth loops formed by the grounding system. The focus here is on cabled grids and the influence of connected structures of the low voltage grid. The second part deals with the superposition of these loop currents and the resulting earth currents in case of a line to ground fault. The authors address explicitly the frequency dependence of the current distribution and describe the expected behaviour for current harmonics. The proposed approaches result from processing the state of knowledge, research work and the evaluation of several measurements. The aim is to develop an understanding of the influence of the components connected to a grounding system and to derive generally applicable principles. Therefore, the authors present the results of recent measurements in the last part of the handed paper and point out the possibilities and limits of modeling. It is shown that a dedicated treatment of harmonic currents in the case of a single-pole fault is possible with the methods described. This allows these to be neglected in the estimation of touch voltages under specified circumstances, saving costs for the assessment of grounding systems.

28 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
USUwe Schubert
Uwe Schubert
ASAli Shirvani
Ali Shirvani
USUwe Schmidt
Uwe Schmidt
SKStefan Kornhuber
Stefan Kornhuber
EKEde Kynast
Ede Kynast
Current atmospheric correction methods for breakdown and withstand voltages in long air-gap configurations show deviations in comparison to measurement data when applied to correct for unusual or atypical atmospheric conditions (i.e., altitudes above 2000 m a.s.l.). The corresponding standards IEC 60060 and IEC 60071 show inconsistencies, although both are being based upon the same measurements and empirical models. In its first part, the concept paper at hand presents the current knowledge and problems of atmospheric correction. In the second part, the authors outline the possible steps for a necessary new investigation as well as the algorithm of a hypothetical correction method. The proposed research is based upon the recent knowledge that any breakdown process in air-gap insulation consists of the sub-processes streamer and leader. While their characteristics seem to be independent of configuration and voltage form, their ratio and proportion varies, which, in turn, defines the value of breakdown voltage. Therefore, the authors propose a sub-process differentiated, measurement-based evaluation of the atmospheric influences air pressure, air humidity, air conductivity and temperature. The main goal is to develop a generic physical model of the breakdown process.

11 September 2018 in Energies
Verified
Journal Article
Open access
PDF file
AHAbdullah Hoshmeh
Abdullah Hoshmeh
USUwe Schmidt
Uwe Schmidt
AGAkif Gürlek
Akif Gürlek
The knowledge about the behavior of cables is substantial in cases of transients or in cases of faults. However, there are only a few models that are tailored to the current requirements for calculations of transient phenomena in three-phase cable systems. These models are based on complex structures. PI-section cable models with simple structures were previously qualified only for calculations in the frequency domain. A new full frequency-dependent cable model to simulate transient phenomena is introduced and validated. The model is based on lumped parameters with cascaded frequency-dependent PI-sections. For the implementation and the integration in simulation tools, it is important to investigate the impact of the PI-section parameters to the accuracy, the stability and the mathematical robustness. In this work, the impact of the frequency dependence of cable parameters, the length distribution and the number of PI-sections on the results of the developed three-phase cable model have been discussed. For simulations in the time domain, two algorithms have been presented to optimize the number of PI-sections based on a specified accuracy.