28 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
TLThomas Linde
Thomas Linde
JLJun Ting Loh
Jun Ting Loh
SKStefan Kornhuber
Stefan Kornhuber
Karsten BackhausKarsten Backhaus
Karsten Backhaus
SSStephan Schlegel
Stephan Schlegel
SGSteffen Großmann
Steffen Großmann
The increasing number of power electronic devices in electrical grids may lead to harmonic distorted voltages, which are considered to be possible causes of component failures. In this study, the dielectric losses of epoxy polymer and functionally filled silicone rubber (f-SiR) samples are investigated under harmonic distorted voltages in terms of their dielectric losses and the consequent heat source density within the material. The results suggest that the epoxy polymer samples behave linearly to the electric field strength and therefore allow good predictability of the dielectric losses. The investigated f-SiR samples exhibit a nonlinear behaviour when an electric field threshold is exceeded. The subsequent direct loss measurements under harmonic distorted voltage reveal a sharp rise of the dielectric loss with increasing electrical field strength. This leads to a higher risk of excessive heat in the material when harmonics are present. In conclusion, the investigation highlights the difficulties of estimating dielectric losses in nonlinear dielectric materials when distorted voltages are present.

10 December 2020 in SPE Polymers
Verified
Journal Article
Open access
PDF file
PVPabbati Vinod
Pabbati Vinod
SASomasundaram Karthikeyan Amizhtan
Somasundaram Karthikeyan Amizhtan
PGParvathy Ganesh
Parvathy Ganesh
SKStefan Kornhuber
Stefan Kornhuber
BSBalaji Srinivasan
Balaji Srinivasan
RSRamanujam Sarathi
Ramanujam Sarathi
Silicone rubber micro‐nanocomposites were fabricated and laser texturing was performed on their surface to investigate super hydrophobic properties. Irrespective of type of texture (square, hexagon or diamond), the contact angle is almost the same but a marginal increase in contact angle is observed with increase in wt% of nano fillers in silicone rubber. Water droplet initiated corona inception voltage (CIV) is measured by fluorescence technique and the CIV tends to increase with texturing and is high under—DC followed with +DC and AC voltages. Fast Fourier Transform (FFT) analysis of the fluorescence signal due to corona discharge indicates that the energy content of the fluorescent signal lies in the range DC to 20 MHz. Surface temperature of the sample after water droplet initiated discharge is found to be high under DC rather than under AC voltages. Textured surface has a relatively lower temperature decay rate under AC and DC voltages profiles, compared to nontextured surface. The formation of shallow charge traps is predominant with the textured specimens. In general, the diamond and hexagonal micro textured surface specimen exhibit better performance in terms of water droplet initiated CIV, hydrophobicity, and surface potential decay characteristics.

1 September 2012
Verified
Conference Paper
Closed access
SKStefan Kornhuber
Stefan Kornhuber
KJK. Jani
K. Jani
MBM. Boltze
M. Boltze
GVG. Valtin
G. Valtin
Like in any high voltage asset, knowledge about the presence of partial discharge in the insulation system can provide vital information about the health condition of HV apparatuses. For switchgears, a traditional PD measurement according to IEC 60270 requires the disconnection of power cables from the switchgear, and the setup of a test circuit at the terminals of it. This includes the shutdown of the switchgear and the connected cable, and comes together with downtime and manual labor on the connectors, which by itself can result in the generation of partial discharge due to mechanical stresses or improper reassembly. This can be avoided by using non-invasive PD detection principles on switchgears, which allow the detection of PD without disconnecting the cables from the switchgear, with a measurement that is performed on-line. By using different possibilities of permanent installed line couplers, VHF, UHF and acoustic sensors the results are different to IEC 60270 measurement (like during the factory acceptance test). The common available non-invasive methods are compared to the IEC 60270 -measurement in the laboratory, whereby only single and defined failures are applied to the switchgear.

17 September 2019 in Energies
Verified
Journal Article
Open access
PDF file
RBRabah Boudissa
Rabah Boudissa
FBFatma BOUCHELGA
Fatma BOUCHELGA
SKStefan Kornhuber
Stefan Kornhuber
KHKlaus Dieter Haim
Klaus Dieter Haim
The purpose of this paper is to characterize the arrangement of raindrops and natural condensation and its effect on the direct current voltage’s flashover of a hydrophobic silicone insulating surface under variable inclination. Two devices have been realized, one for on-site exposure of insulation samples under rain and condensation, and the other for laboratory use in order to allow the variation of the angle of their inclination. The temporal evolution of the constellation of raindrops and natural condensation as well as the electrical discharge produced in the laboratory was visualized. The results emanated from the on-site investigation allowed the identification of the most reproducible type of arrangement of rainwater and natural condensation drops as well as the estimation of their respective volume. The results from the laboratory clearly show the existence of an interval of the insulation’s inclination angle, which allows the best approximation of its electrical performance to what was obtained in the absence of these drops. Moreover, these same results also inform us about some very critical situations to avoid regarding the insulation by a judicious choice of its inclination angle.

28 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
USUwe Schubert
Uwe Schubert
ASAli Shirvani
Ali Shirvani
USUwe Schmidt
Uwe Schmidt
SKStefan Kornhuber
Stefan Kornhuber
EKEde Kynast
Ede Kynast
Current atmospheric correction methods for breakdown and withstand voltages in long air-gap configurations show deviations in comparison to measurement data when applied to correct for unusual or atypical atmospheric conditions (i.e., altitudes above 2000 m a.s.l.). The corresponding standards IEC 60060 and IEC 60071 show inconsistencies, although both are being based upon the same measurements and empirical models. In its first part, the concept paper at hand presents the current knowledge and problems of atmospheric correction. In the second part, the authors outline the possible steps for a necessary new investigation as well as the algorithm of a hypothetical correction method. The proposed research is based upon the recent knowledge that any breakdown process in air-gap insulation consists of the sub-processes streamer and leader. While their characteristics seem to be independent of configuration and voltage form, their ratio and proportion varies, which, in turn, defines the value of breakdown voltage. Therefore, the authors propose a sub-process differentiated, measurement-based evaluation of the atmospheric influences air pressure, air humidity, air conductivity and temperature. The main goal is to develop a generic physical model of the breakdown process.

25 March 2022 in Nature Conservation
Verified
Journal Article
Open access
PDF file
SKStefan Kornhuber
Stefan Kornhuber
HPHans-Peter Pampel
Hans-Peter Pampel
JGJana Görlich
Jana Görlich
MLMarion Leiblein-Wild
Marion Leiblein-Wild
CJChristoph Jöckle
Christoph Jöckle
In contrast to other transportation systems, railway systems feature special characteristics, which may cause specific hazards to birds. Among other things, there is the risk of electrocutions resulting from short circuits. To protect the birds and minimize these short circuit events, the DB Netz AG has installed so-called animal deflectors on the insulators of the overhead lines. Since this effort, the number of short-circuit events in the respective sections has decreased, according to DB Netz AG. The principal mechanism of action of the animal deflectors is based on mechanical defense, combined with electrostatic discharge on contact. Although the number of short circuit events has been reduced by using animal deflectors, the detailed function of the animal deflector in different environmental conditions has not been investigated up to now. This research project aims to determine whether, and to what extent, the use of animal deflectors in retrofitting overhead lines may contribute to bird protection and which currents can be measured at retrofitted insulators under different environmental conditions. Hence the current should be measured when using animal deflectors on railway overhead lines for different isolator states and body resistances (5 kΩ, 3 kΩ, 1kΩ, 0.5 kΩ). The results show an influence of measured current depending on the insulator state. Our preliminary results indicate that the use of an animal deflector (KTA) to the tested polymeric insulator and pollution severity can be recommended, since, based on the investigations, no danger to small birds and small animals can be identified. However, the use of the animal deflector (KTA) for the tested porcelain insulator and pollution severity should not be recommended as they showed high animal hazards during pollution and fog conditions. However, these results cannot be transferred to other different insulator types and pollution severities. Investigating the electrical current to the type of insulator used and the expected pollution severity is recommended.