For a realistic simulation of low voltage distribution grids containing mainly household loads and distributed photovoltaic systems, a temporal resolution of one minute is proposed in this paper. Data sets of domestic household load profiles and solar irradiance data with a temporal resolution of one second are analysed with different statistical approaches. Although any averaging of measurement data causes information loss, the loss of information only increases rapidly if a temporal resolution of more than one minute is employed.
This study analyses 30+ years of PV performance in Switzerland, highlighting the reliability of early 90s modules. It examines outdoor system- and indoor module-level data, emphasising the importance of BOM and the benefits of lower temperatures.
With the increasing prevalence of photovoltaic (PV) installations on north-facing roofs in urban areas, the issue of glare on PV modules is becoming more significant. This paper presents a method for measuring and characterising the intensity and type of glare using a commercially available photo camera. The method utilises the fact that brightness information is inherently contained in a photograph. Due to the strong non-linearity of brightness information in an image, especially when using High Dynamic Range (HDR) functionality, an image needs to be divided into multiple sub-images with clearly defined settings, and the linear range extracted from each of them. The information obtained in this way is then assembled into a new image. The resulting luminance image describes the intensity and shape of glare, forming the basis for calculating the occurrence of glare (times and days of the year) in a simplified manner.
PV array simulators are devices for PV and PV battery inverter testing. To ensure that these devices operate correctly and can realistically simulate PV modules and PV arrays, a test procedure for the assessment of PV array simulators has been developed and is presented in this paper. This procedure helps testing laboratories to evaluate PV array simulators and leads to more uniform test conditions. Furthermore, it assists developers of such simulators in understanding the requirements, enabling them to optimize and test their devices accordingly. The proposed test series includes three phenomenological observations, in which the interaction between the PV array simulator and a randomly selected PV inverter is tested. Subsequently, three potentially standardisable tests are proposed in which certain properties, such as the accuracy and frequency response of the PV array simulators are tested and evaluated.
The increasing use of plug and play photovoltaic systems has raised concerns about their safety, especially with nonprofessional installations, which existing standards only partially address. This study proposes a black box testing approach to assess the personal safety of plug and play inverters. A total of 25 microinverters are assessed using three tests: (1) analyzing the residual voltage at the mains plug after disconnection, (2) the feed‐in current increase under low grid voltage conditions, and (3) the maximum touch temperature during operation. Residual voltage testing reveals that 56% of the inverters comply with the limit of the latest official German plug and play system standard draft and behave similarly to other tested electrical devices. Further investigation is required to determine if exceeding this limit presents a direct safety risk. However, adding a relay was identified as an effective measure to ensure compliance. Under low voltage conditions, current increases up to 26.3% were measured, potentially stressing nondedicated circuits. In the temperature test, a positive correlation between the inverters power density and the touch temperature was found. The findings of this analysis provide insights for future standardization efforts and offer guidance to manufacturers in improving the safety of these PV systems.