Recently, a minimally invasive treatment for lacrimal passage diseases was developed using dacryoendoscopy. Good visibility of the lacrimal passage is important for examination and treatment. This study aimed to investigate whether image processing can improve the dacryoendoscopic visibility using comb-removal and image-sharpening algorithms. We processed 20 dacryoendoscopic images (original images) using comb-removal and image-sharpening algorithms. Overall, 40 images (20 original and 20 post-processing) were randomly presented to the evaluators, who scored each image on a 10-point scale. The scores of the original and post-processing images were compared statistically. Additionally, in vitro experiments were performed using a test chart to examine whether image processing could improve the dacryoendoscopic visibility in a turbid fluid. The visual score (estimate ± standard error) of the images significantly improved from 3.52 ± 0.26 (original images) to 5.77 ± 0.28 (post-processing images; p < 0.001, linear mixed-effects model). The in vitro experiments revealed that the contrast and resolution of images in the turbid fluid improved after image processing. Image processing with our comb-removal and image-sharpening algorithms improved dacryoendoscopic visibility. The techniques used in this study are applicable for real-time processing and can be easily introduced in clinical practice.
This prospective case series aimed to investigate the contrast sensitivity function before and after lacrimal passage intubation (LPI) in eyes with epiphora due to lacrimal passage obstruction. We included 58 eyes of 51 patients who underwent LPI for lacrimal passage obstruction. The best-corrected visual acuity (BCVA), contrast sensitivity function, and lower tear meniscus were compared before LPI and one month after lacrimal duct stent removal. The area under the log contrast sensitivity function (AULCSF) was calculated for the analyses. Lower tear meniscus was assessed using anterior segment optical coherence tomography. The BCVA was comparable (p = 0.61) before and after LPI, while AULCSF increased significantly after treatment (before LPI: 1.29 ± 0.17, after LPI: 1.37 ± 0.14, p < 0.0001). Treatment resulted in a significant increase in contrast sensitivity at all spatial frequencies, 3–18 cycles/degree (p < 0.01 for 3, p < 0.01 for 6, p < 0.0005 for 12, p < 0.05 for 18 cycles/degree). The lower tear meniscus parameters improved significantly after treatment (p < 0.005); however, no correlation between the changes in the tear meniscus and those of the AULCSF was found. The contrast sensitivity significantly improved after LPI in eyes with epiphora due to lacrimal passage obstruction.
Endoscopic vitrectomy with small gauge probes has clinical potentials, but intraocular visibility is inherently limited by low resolution and dim illumination due to the reduced number of optic fibers. We investigated whether honeycomb-removal and image-sharpening algorithms, which enable real-time processing of live images with a delay of 0.004 s, can improve the visibility of 27-gauge endoscopic vitrectomy. A total of 33 images during endoscopic vitrectomy were prepared, consisting of 11 original images, 11 images after the honeycomb-removal process, and 11 images after both honeycomb-removal and image-sharpening procedures. They were randomly presented to 18 vitreous surgeons, who rated each image on a 10-point scale. The honeycomb-removal algorithm almost completely suppressed honeycomb artifacts without degrading the background image quality. The implementation of image-sharpening algorithms further improved endoscopic visibility by optimizing contrast and augmenting image clarity. The visibility score was significantly improved from 4.27 ± 1.78 for the original images to 4.72 ± 2.00 for the images after the honeycomb-removal process (p < 0.001, linear mixed effects model), and to 5.40 ± 2.10 for the images after both the honeycomb-removal and image-sharpening procedures (p < 0.001). When the visibility scores were analyzed separately for 10 surgeons who were familiar with endoscopic vitrectomy and 8 surgeons who were not, similar results were obtained. Image processing with honeycomb-removal and image-sharpening algorithms significantly improved the visibility of 27-gauge endoscopic vitrectomy.
Background: Traumatic intracranial aneurysms (TICAs) can be fatal if ruptured. We report a case of a TICA, distant from facial bone fractures, successfully treated with flow diverter (FD) before rupture. Case Presentation: A 20‐year‐old woman was admitted following a car accident. Initial contrast‐enhanced computed tomography revealed traumatic subarachnoid hemorrhage, a 5‐mm internal carotid artery aneurysm, LeFort type I + II, and mandibular fracture. On Day 8, she developed oculomotor palsy, and digital subtraction angiography revealed the aneurysm had increased to 12 mm. She started dual antiplatelet therapy (DAPT) following facial fracture repair. On Day 17, FD was placed, resulting in contrast agent stagnation within the aneurysm. Three months postinjury, her neurological symptoms improved. Conclusion: Screening for cerebrovascular injury is crucial several days following severe head trauma, even without skull base fractures. Unruptured TICA can be safely treated with FD following DAPT administration.
Background/Objectives: Lacrimal passage intubation is commonly used to treat lacrimal duct obstruction. However, conventional dacryoendoscopes, which are limited by their low resolution and comb-structure artifacts, pose challenges for visualization. Two novel image processing algorithms—comb removal and image sharpening—have been developed to enhance visibility, and this study aimed to evaluate the clinical effects of these algorithms on the outcomes of dacryoendoscopic surgery. Methods: A retrospective study was conducted on 121 sides of 84 patients (mean age, 72.3 ± 10.5 years) who had undergone lacrimal passage intubation. The patients were categorized into comb-removal and image-sharpening groups according to the algorithm used during the procedure. The clinical parameters of pain score, endoscopy duration, irrigation fluid volume, and irrigation fluid flow rate were compared between the groups using the linear mixed-effects model, and recurrence rates were evaluated using Kaplan–Meier analysis. Results: The image-sharpening algorithm was associated with a significant reduction in irrigation fluid usage (β = −1.34 mL, SE = 0.52, p = 0.012), with the pain score (β = −1.71, SE = 0.93, p = 0.069) and endoscopy duration (β = −0.50 min, SE = 0.39, p = 0.199) also showing reduction trends, but these did not reach statistical significance. The comb-removal algorithm showed no significant associations with any evaluated outcome. Recurrence rates were similar between the groups. Conclusions: Real-time image sharpening was associated with improved procedural efficiency during dacryoendoscopic surgery, while clinical outcomes showed favorable trends that did not reach statistical significance. These findings suggest a potential supportive role of these algorithms in intraoperative handling; however, whether this translates into clinically meaningful benefits requires further investigation.