Yasukazu Totoki

Dr. Yasukazu Totoki

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
SKSho Kohyama
Sho Kohyama
YNYasumasa Nishiura
Yasumasa Nishiura
YHYUKI HARA
YUKI HARA
TOTakeshi Ogawa
Takeshi Ogawa
AIAkira Ikumi
Akira Ikumi
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
We used our novel three-dimensional magnetic resonance imaging-computed tomography fusion images (3D MRI-CT fusion images; MCFIs) for detailed preoperative lesion evaluation and surgical simulation in osteochondritis dissecans (OCD) of the elbow. Herein, we introduce our procedure and report the findings of the assessment of its utility. We enrolled 16 men (mean age: 14.0 years) and performed preoperative MRI using 7 kg axial traction with a 3-Tesla imager and CT. Three-dimensional-MRI models of the humerus and articular cartilage and a 3D-CT model of the humerus were constructed. We created MCFIs using both models. We validated the findings obtained from the MCFIs and intraoperative findings using the following items: articular cartilage fissures and defects, articular surface deformities, vertical and horizontal lesion diameters, the International Cartilage Repair Society (ICRS) classification, and surgical procedures. The MCFIs accurately reproduced the lesions and correctly matched the ICRS classification in 93.5% of cases. Surgery was performed as simulated in all cases. Preoperatively measured lesion diameters exhibited no significant differences compared to the intraoperative measurements. MCFIs were useful in the evaluation of OCD lesions and detailed preoperative surgical simulation through accurate reproduction of 3D structural details of the lesions.

18 August 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
YEYusuke Eda
Yusuke Eda
RAReo Asai
Reo Asai
SKSho Kohyama
Sho Kohyama
AIAkira Ikumi
Akira Ikumi
YTYasukazu Totoki
Yasukazu Totoki
YYYuichi Yoshii
Yuichi Yoshii
In cases of distal radius fractures, the fixation of the volar lunate facet fragment is crucial for preventing volar subluxation of the carpal bones. This study aims to clarify the sex differences in the volar morphology of the lunate facet of the distal radius and its relationship with the transverse diameter of the distal radius. Sixty-four CT scans of healthy wrists (30 males and 34 females) were evaluated. Three-dimensional (3D) images of the distal radius were reconstructed from the CT data. We defined reference point 1 as the starting point of the inclination toward the distal volar edge, reference point 2 as the volar edge of the joint on the bone axis, and reference point 3 as the volar edge of the distal radius lunate facet. From the 3D coordinates of reference points 1 to 3, the bone axis distance, volar−dorsal distance, radial−ulnar distance, 3D straight-line distance, and inclination angle were measured. The transverse diameter of the radius was measured, and its correlations with the parameters were evaluated. It was found that in males, compared to females, the transverse diameter of the radius is larger and the protrusion of the volar lunate facet is greater. This suggests that the inclination of the volar surface is steeper in males and that the volar locking plate may not fit properly with the volar cortical bone of the lunate facet, necessitating additional fixation.

26 January 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KNKatsuya Nagashima
Katsuya Nagashima
YHYUKI HARA
YUKI HARA
HMHirotaka Mutsuzaki
Hirotaka Mutsuzaki
YTYasukazu Totoki
Yasukazu Totoki
EOEriko Okano
Eriko Okano
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
To solve the instrument loosening problem, we developed a fibroblast growth factor-2-calcium phosphate composite layer as a novel coating material to improve screw fixation strength. The primary aim of the present study was to demonstrate the safety and feasibility of screws coated with the FGF-2-calcium phosphate composite layer for posterior instrumented surgery of the cervical spine. The trial design was a single-arm, open-label, safety and feasibility study. Patients receiving fusion of the cervical spine from C2 (or C3) to C7 (or T1) were recruited. The primary endpoint to confirm safety was any screw-related adverse events. Seven patients who underwent posterior fusion surgery of the cervical spine were enrolled in the present study. The coated pedicle screws were inserted bilaterally into the lowest instrumented vertebrae. There was only one severe adverse event unrelated with the coated screw. Three out of the fourteen coated screws showed loosening. The present results prove the safety and feasibility of pedicle screws coated with the FGF-2-calcium phosphate composite layer for fusion surgery in the cervical spine. This is the first step to apply this novel surface coating in the field of spine surgery.

24 January 2025 in Acute Medicine & Surgery
Verified
Journal Article
Open access
TWTatsuya Watanabe
Tatsuya Watanabe
JNJunzo Nakao
Junzo Nakao
KBKeishun Boku
Keishun Boku
KHKoji Hirata
Koji Hirata
YTYasukazu Totoki
Yasukazu Totoki
YIYoshiaki Inoue
Yoshiaki Inoue
Background: Traumatic intracranial aneurysms (TICAs) can be fatal if ruptured. We report a case of a TICA, distant from facial bone fractures, successfully treated with flow diverter (FD) before rupture. Case Presentation: A 20‐year‐old woman was admitted following a car accident. Initial contrast‐enhanced computed tomography revealed traumatic subarachnoid hemorrhage, a 5‐mm internal carotid artery aneurysm, LeFort type I + II, and mandibular fracture. On Day 8, she developed oculomotor palsy, and digital subtraction angiography revealed the aneurysm had increased to 12 mm. She started dual antiplatelet therapy (DAPT) following facial fracture repair. On Day 17, FD was placed, resulting in contrast agent stagnation within the aneurysm. Three months postinjury, her neurological symptoms improved. Conclusion: Screening for cerebrovascular injury is crucial several days following severe head trauma, even without skull base fractures. Unruptured TICA can be safely treated with FD following DAPT administration.

30 August 2024 in Medicina
Verified
Journal Article
Open access
PDF file
YTYasukazu Totoki
Yasukazu Totoki
HMHirotaka Mutsuzaki
Hirotaka Mutsuzaki
YYYohei Yanagisawa
Yohei Yanagisawa
YSYu Sogo
Yu Sogo
MYMayu Yasunaga
Mayu Yasunaga
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
Background: The most problematic complication of external fixation is infection at the pin insertion site. Technology that improves the adhesion of the external fixation pin to the skin, subcutaneous tissue, and bone may prevent infection at the pin site. The purpose of this study is to formulate a calcium phosphate–fibroblast growth factor (Cp-FGF) coating on a stainless-steel external fixation pin and to verify its effectiveness in reducing infection at the pin site and its possible influence on bone fixation in animal experiments. Methods: We compared stainless-steel screws without coating (SS group; n = 32), those with a calcium phosphate coating (Cp group; n = 30), those with a Cp-FGF coating (FGF group; n = 32), and those with a Cp-FGF coating having enhanced biological activity (FGF+ group; n = 32) in male Japanese white domesticated rabbits. Screws were inserted percutaneously into the bilateral proximal tibial diaphysis of the rabbits and implanted for 4 weeks. Screws and periscrew tissue were observed postoperatively for qualitatively assessing infection. Results: Infection assessment by gross findings after 4 weeks (at screw removal) showed no significant differences between the groups. Histopathological evaluation of soft tissue infection and bone tissue infection showed no significant differences between the groups for either soft tissue or bone tissue. Since neither the FGF+ group nor the FGF group showed anti-infective effects, the biological activity of FGF is not the only determining factor. We compared SEM, XRD, coating detaching test, sustained release test, and bioassay to examine physicochemical properties among the coatings but found no sufficient differences. Conclusions: It is suggested that improving the tissue adhesion to and/or biocompatibility of pins is also important to improve the in vivo performance of Cp-FGF-coated external fixation pins.

1 October 2026 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Open access
YTYasukazu Totoki
Yasukazu Totoki
YYYohei Yanagisawa
Yohei Yanagisawa
AIAkira Ikumi
Akira Ikumi
YWYu Watanabe
Yu Watanabe
YEYusuke Eda
Yusuke Eda
YHYasuhiro Homma
Yasuhiro Homma
Double-plate fixation is widely used for transcondylar fractures of the distal humerus in elderly patients. Recently, fixation using a medial column screw (MCS) without a medial plate has been reported. However, anatomical data regarding optimal screw diameter and insertion trajectories are scarce. This study aimed to clarify the anatomical basis of MCS fixation using CT-based morphologic analysis. We retrospectively analyzed CT data from 92 humeri (51 male, 41 female) obtained between 2012 and 2023. A virtual cylinder was placed along the medial column, and the maximum diameter without cortical breach and insertion angles relative to the humeral axis were measured. Measurement reliability was assessed using intraclass correlation coefficients (ICC), and factors associated with cylinder diameter were assessed using multiple linear regression. The overall mean cylinder diameter was 6.4 mm ( 95% CI, 6.1-6.7 mm) and was significantly larger in males than in females (P < .001), with no significant age-related difference. Among humeri from individuals aged ≥ 65 years, 25 of 26 (96.2%) accommodated a cylinder diameter of at least 5.0 mm; the observed minimum diameter was 6.0 mm in males and 4.0 mm in females. Sex, age, and body weight were independently associated with cylinder diameter, whereas height was not. Mean insertion angles were 12° axial, 9° sagittal, and 33° coronal. Intraobserver and interobserver ICC values for diameter were 0.86 and 0.67, respectively, whereas those for insertion angles were lower. The medial column anatomically accommodated a diameter of at least 5.0 mm in most elderly patients. An approximately 5.0-mm MCS may therefore represent a candidate diameter when individual anatomy permits, although insertion trajectories require patient-specific adjustment and biomechanical validation is needed.