The water quality index model is a popular tool for evaluating drinking water quality. To overcome low precision and significant errors in the traditional single prediction model, a novel autoregressive integrated moving average (ARIMA)-sparrow search algorithm (SSA)-long short-term memory (LSTM) combination model is proposed to accurately predict residual chlorine, turbidity, and pH in drinking water. First, the ARIMA model is used to extract the linear part of water quality data and output the nonlinear residual. Then, the LSTM model is used to predict the residual, and the SSA is used to find the optimal hyperparameters of the LSTM model, which plays an essential role in reducing the error of the model. To prove the superiority of the model developed, the ARIMA-SSA-LSTM model is compared with SSA-LSTM, whale optimization algorithm-LSTM, PSO-LSTM, ARIMA-LSTM, ARIMA, and LSTM. The results show that the coefficient of determination (R2) of the combination model for residual chlorine, turbidity, and pH are 0.950, 0.990, and 0.998, respectively, which are greater than all comparison models. Therefore, the model is more suitable for the prediction and analysis of water quality data.
To address the problem of easily falling into local optimization and low convergence accuracy in the path planning tasks of mobile robots, an Improved Crested Porcupine Optimizer (ICPO) based on chaotic mapping is proposed. The ICPO algorithm employs a three-step optimization process. First, it utilizes SPM, a piecewise linear chaotic initialization, to optimize the population thereby enhancing its diversity and global coverage. Second, the Cauchy Distribution Inverse Cumulative Operator is incorporated to prevent convergence to local optima and to accelerate the overall convergence rate. Finally, the Gaussian mutation is applied to strengthen ICPO’s local exploitation capabilities. Comparative analysis of five algorithms (PSO, DBO, GOOSE, CPO, and ICPO) is conducted using eight standard benchmark functions. Results demonstrate that ICPO achieves a faster convergence rate and superior convergence accuracy. Furthermore, in path planning experiments within 20 × 20 and 40 × 40 grid maps, ICPO reduced the path length by 4.53% and 8.99%, respectively, compared to the CPO algorithm.
A steady-state sinusoidal and distortion-free excitation source is very important for the accuracy and consistency of the calibration parameters of micro-electro-mechanical systems (MEMS) inertial sensors. To solve the problem that the current MEMS inertial measurement unit (IMU) calibration device is unable to reproduce the spatial motion of linear and angular vibration coupling, research topics on the coupling vibration characteristics and parameter identification for an electromagnetic linear-angular vibration exciter are proposed. This research paper used Ampere’s law and Lorentz force to establish the analytical expressions for the electromagnetic force and electromagnetic torque of the electromagnetic linear-angular vibration exciter. Then, the main purpose of this paper is to establish uniaxial and coupled vibration electromechanical analogy models containing mechanical parameters based on the admittance-type electromechanical analogy principle, and the parameter identification model is also obtained by combining the impedance formula with the additional mass method. Finally, the validity of the coupling vibration characteristics and the parameter identification model are verified by the frequency response simulation and the additional mass method, and the relative error of each parameter identification is within 5% in this paper.
5 September 2024 in Measurement Science and Technology
Turbidity is regarded as a comprehensive indicator in water quality monitoring, and the turbidity sensor deployed in the water supply network can record the dynamic changes of water quality in time. However, the weak photoelectric signal from the photodetector contains a quantity of noise. In order to improve signal-to-noise ratio, a novel on-line turbidity sensor based on quadrature demodulation principle has been proposed in this paper. A near-infrared light-emitting diode (LED) with a wavelength of 860 nm was selected as a stable monochromatic light source, and a photodiode with an angle of 90° to the incident light from the LED was selected as the photodetector. Using signal modulation and demodulation technology, the weak photoelectric signal extraction, conversion, amplification and output of the turbidity sensor were realized through the effective integration. A corresponding test apparatus of the turbidity sensor was established and experimental results showed that within a 0–5 NTU measurement range, the turbidity sensor had good linearity and stability, the relative measurement error was within ±1% and the limit of detection could reach as low as 0.0049 NTU. The developed turbidity sensor has good detection performance and can meet the needs of low turbidity detection of drinking water.
This study proposes a method for measuring guide rail parallelism based on position-sensitive detectors (PSDs), establishing a comprehensive uncertainty assessment framework. Parallelism errors are calculated using the public benchmark method and least squares fitting, with uncertainty components quantified via a dissemination of the value of quantity model. The reliability of the assessment is verified using the Monte Carlo method, yielding a 95% confidence interval of 10.0–14.0 μm. The innovative introduction of a conjugate prior Bayesian framework enables dynamic updating of repeatability uncertainty, reducing the expanded uncertainty by 10% (from 2.0 μm to 1.8 μm, k = 2). Comparative laser interferometer experiments demonstrate that while the interferometer offers higher precision (0.8 μm), the PSD system maintains 1.8 μm accuracy at a 33% lower cost (from ¥300 000 to ¥200 000). It supports 8 h of operation without an external power supply, offering superior portability and industrial adaptability.