Dhanashree Abhijit Rajderkar

Dr. Dhanashree Abhijit Rajderkar

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2023 in Journal of Neurotrauma
Verified
Journal Article
Closed access
JPJennifer Christine Munoz Pareja
Jennifer Christine Munoz Pareja
Juan Pablo de Rivero VaccariJuan Pablo de Rivero Vaccari
Juan Pablo de Rivero Vaccari
MCMaria Mateo Chavez
Maria Mateo Chavez
MKMaria Kerrigan
Maria Kerrigan
Charlene P. PringleCharlene P. Pringle
Charlene P. Pringle
KWKevin Wang
Kevin Wang
Traumatic brain injury (TBI) remains a major cause of morbidity and death among the pediatric population. Timely diagnosis, however, remains a complex task because of the lack of standardized methods that permit its accurate identification. The aim of this study was to determine whether serum levels of brain injury biomarkers can be used as a diagnostic and prognostic tool in this pathology. This prospective, observational study collected and analyzed the serum concentration of neuronal injury biomarkers at enrollment, 24h and 48h post-injury, in 34 children ages 0–18 with pTBI and 19 healthy controls (HC). Biomarkers included glial fibrillary acidic protein (GFAP), neurofilament protein L (NfL), ubiquitin-C-terminal hydrolase (UCH-L1), S-100B, tau and tau phosphorylated at threonine 181 (p-tau181). Subjects were stratified by admission Glasgow Coma Scale score into two categories: a combined mild/moderate (GCS 9–15) and severe (GCS 3–8). Glasgow Outcome Scale-Extended (GOS-E) Peds was dichotomized into favorable (≤4) and unfavorable (≥5) and outcomes. Data were analyzed utilizing Prism 9 and R statistical software. The findings were as follows: 15 patients were stratified as severe TBI and 19 as mild/moderate per GCS. All biomarkers measured at enrollment were elevated compared with HC. Serum levels for all biomarkers were significantly higher in the severe TBI group compared with HC at 0, 24, and 48h. The GFAP, tau S100B, and p-tau181 had the ability to differentiate TBI severity in the mild/moderate group when measured at 0h post-injury. Tau serum levels were increased in the mild/moderate group at 24h. In addition, NfL and p-tau181 showed increased serum levels at 48h in the aforementioned GCS category. Individual biomarker performance on predicting unfavorable outcomes was measured at 0, 24, and 48h across different GOS-E Peds time points, which was significant for p-tau181 at 0h at all time points, UCH-L1 at 0h at 6–9 months and 12 months, GFAP at 48h at 12 months, NfL at 0h at 12 months, tau at 0h at 12 months and S100B at 0h at 12 months. We concluded that TBI leads to increased serum neuronal injury biomarkers during the first 0–48h post-injury. A biomarker panel measuring these proteins could aid in the early diagnosis of mild to moderate pTBI and may predict neurological outcomes across the injury spectrum.

16 September 2022 in Pediatric Blood & Cancer
Verified
Journal Article
Closed access
JMJoyce Mhlanga
Joyce Mhlanga
HLHollie Lai
Hollie Lai
AAAdina Alazrkai
Adina Alazrkai
SCSteve Y Cho
Steve Y Cho
HNHelen Nadel
Helen Nadel
KMKathleen McCarten
Kathleen McCarten

1 September 2018 in Current Problems in Diagnostic Radiology
Verified
Journal Article
Closed access
PBPhillip Bates
Phillip Bates
DRDhanashree Abhijit Rajderkar
Dhanashree Abhijit Rajderkar

14 December 2020 in Journal of Perinatology
Verified
Journal Article
Closed access
PDF file
PNParvathi Nataraj
Parvathi Nataraj
MSMarcela Svojsik
Marcela Svojsik
LSLivia Sura
Livia Sura
KCKelly Curry
Kelly Curry
NBNikolay Bliznyuk
Nikolay Bliznyuk
MWMichael D. Weiss
Michael D. Weiss

27 January 2022 in British Journal of Radiology
Verified
Journal Article
Open access
PSPriya G. Sharma
Priya G. Sharma
DRDhanashree Abhijit Rajderkar
Dhanashree Abhijit Rajderkar
CSChristopher L Sistrom
Christopher L Sistrom
RSRoberta M. Slater
Roberta M. Slater
AMAnthony A. Mancuso
Anthony A. Mancuso
Objectives: Pneumatosis intestinalis is a radiographic finding that refers to the presence of gas within the walls of the small or large bowel. This sign is diagnostic in the setting of premature infants with suspected necrotizing enterocolitis. Earlier detection of NEC on X-ray is vital to improve the overall management in these infants. The identification of pneumatosis intestinalis concerning for necrotizing enterocolitis by the “on-call” trainee is critical in the care of the preterm infant. Our objective was to study trainees’ ability to identify pneumatosis on an emergent overnight film. Methods: The Emergent/Critical Care Imaging SIMulation (WIDI SIM) is a strategically designed computer-aided simulation of an emergency imaging experience that has been rigorously tested and proven to be a reliable means for assessing radiology trainee preparedness to competently and independently cover radiology call. One test case each year included requires the trainee to accurately identify pneumatosis on a plain radiograph of the abdomen in a neonate. Results: A total of 463 radiology trainees from 32 distinct training programs across the country were given a case of pneumatosis using the WIDI simulation web-based testing platform. On average only 28% of radiology trainees were able to correctly identify pneumatosis intestinalis on plain film. Although the sample sizes in the upper-level trainees were smaller, those with greater number years of training performed better. Conclusions: Further training must be given to radiology trainees to accurately recognize pneumatosis and report concerns for necrotizing enterocolitis. Advances in knowledge: This paper is the first to describe and assess the ability of the “on-call” radiology trainee to accurately recognize pneumatosis and report concerns for necrotizing enterocolitis. Our paper includes the largest cohort of radiology trainees evaluated to this date.

1 July 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
EMEmily L Marshall
Emily L Marshall
DRDhanashree Abhijit Rajderkar
Dhanashree Abhijit Rajderkar
JBJustin L Brown
Justin L Brown
ESElliott J Stepusin
Elliott J Stepusin
DBDavid Borrego
David Borrego
WBWesley E Bolch
Wesley E Bolch
Of all the medical imaging modalities that utilize ionizing radiation, fluoroscopy proves to be the most difficult to assess values of patient organ dose owing to the dynamic and patient-specific nature of the irradiation geometry and its associated x-ray beam characteristics. With the introduction of the radiation dose structured report (RDSR) in the mid-2000s, however, computational tools have been developed to extract patient and procedure-specific data for each irradiation event of the study, and when coupled to a computational phantom of the patient, values of skin and internal organ dose may be assessed. Unfortunately, many legacy and even current diagnostic fluoroscopy units do not have RDSR reporting capabilities, thus limiting these dosimetry reporting advances. Nevertheless, knowledge of patient organ doses for patient care, as well as for radiation epidemiology studies, remains a research and regulatory priority. In this study, we created procedural outlines which document all radiation exposure information required for organ dose assessment, akin to a reference RDSR, for six common diagnostic fluoroscopy procedures performed at the University of Florida (UF) Shands Pediatric Hospital. These procedures include the voiding cystourethrogram, the gastrostomy-tube placement, the lower gastrointestinal study, the rehabilitation swallow, the upper gastrointestinal study, and the upper gastrointestinal study with follow through. These procedural outlines were used to develop an extensive database of organ doses for the 162-member UF/NCI (National Cancer Institute) library of pediatric hybrid phantoms, with each member varying combinations of sex, height, and weight. The organ dose assessment accounts for the varying x-ray fields, fluoroscopy time, relative concentration of x-ray contrast in the organs, and changes in the fluoroscope output due to patient size. Furthermore, we are also reporting organ doses normalized to total fluoroscopy time, reference point air kerma, and kerma-area product, effectively providing procedure dose coefficients. The extensive organ dose library produced in this study may be used prospectively for patient organ dose reporting or retrospectively in epidemiological studies of radiation-associated health risks.